15 SEER USER’ s MANU AL & INST ALLA TION INSTR UCTIONS Single P acka g e Heat Pump - 2 Stage, R-410A Please read this inf or mation thoroughly and become familiar with the capabilities and use of y our appliance bef ore attempting to operate or maintain this unit.
2 Safety Inf ormation ........................................ 4 General Information ..................................... 4 Bef ore Y ou Install this Unit .......................... 4 Locating the Heat pump ............................ 4 Air Duct System .
3 Figure 1. Digital Thermostat Fa n Mode T emperature Selector System Mode ABOUT THE HEA T PUMP Y our heat pump is a unique, all w eather comf or t- control appliance that will heat and cool your home year round and pro vide energy saving comf or t.
4 GENERAL INFORMA TION Single packaged heat pumps are ready f or easy and immediate installation and can be readily connected into the high static duct system of a home. This unit is completely assembled, wired, and run tested at the factory . This heat pump is designed for outdoor installation onl y .
5 HEA T PUMP INST ALLA TION Unpacking the Unit It is recommended that the unit be unpack ed at the installation site to minimize damage due to handling. CA UTION: Do not tip the unit on its side. Oil may enter the compressor c ylinders and cause starting trouble.
6 2. Overlap the collar ends k eeping the small screw holes underneath. 3. Align the holes in the crimped area and install one screw . NOTE: It may be necessary to loosen the f our screws that hold the transition duct in order to install the supply fi tting.
7 Figure 7. Supply Damper A UTOMA TIC DAMPER IS CLOSED WHEN HEA T PUMP IS OFF Figure 6. Return Air Box NO TE: The return air box with g r ille and fi lter (Figure 6) should not be located in heavy tr affi c areas like hallw ays or center of rooms . A good spot is in a cor ner or under a tab le, if a minim um two inch clearance is a vailab le.
8 Figure 8. P ower Entry Low V oltage High V oltage ELECTRICAL CONNECTIONS W ARNING: To av oid electric shock, personal injury , or death, turn off the electric power at the disconnect or the main service panel before making an y electrical connections.
9 Blower Speed F or optimum system performance and comfort, it ma y be necessar y to change the factory speed setting. See T able 4 (page 20) f or factory settings.
10 Thermostat Connections • The Q5RF heat pump is a two stage cooling and heating appliance that requires a 2-stage Cooling/Heating ther mostat. The heat-cool ther mostat pre vents simultaneous oper.
11 Figure 10. T ypical Heat Pump Thermostat Connections T ypical Wiring (Field Supplied) for 2-Stage Cool, 2-Stage Electric Heat T ypical Wiring (Field Supplied) for 2-Stage Cool, 1 Stage Electric Hea.
12 ST ARTUP & ADJUSTMENTS Pre-Start Checklist The f ollowing check list should be observed prior to star ting the unit. Is the unit lev el? Unit should be lev el or slightly slanted tow ard the drain for proper condensate drainage .
13 Cooling Mode When the TEST pins are shor ted together for more than 1 second, the Anti Shor t Cycle Timer will be bypassed. Adjustment of Refrigerant Charge CA UTION: This heat pump contains liquid and gaseous refrigerant under pressure .
14 Refrigerant Charging Charts for Cooling Mode of Operation Figure 11. Charging Chart for 2 ton Units 200 225 250 275 300 325 350 375 400 425 450 475 500 525 550 575 600 70 75 80 85 90 95 100 105 110.
15 Refrigerant Charging Charts for Cooling Mode of Operation - Continued Figure 14. Charging Chart for 5 ton Units 200 225 250 275 300 325 350 375 400 425 450 475 500 525 550 575 600 70 75 80 85 90 95.
16 Q5RF-X24K OUTDOOR TEMPERA TURE (DEG. F) 0 1 02 03 04 05 06 0 Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Press Press. T emp . Press. Press. T emp. Press. Press.
17 T able 3. Refrig erant Charging T ables f or Heating Mode of Operation - 4 & 5 T on Units Q5RF-X48K OUTDOOR TEMPERA TURE (DEG. F) 0 1 02 03 04 05 06 0 Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch. Suc. Liquid Disch.
18 3. Not sutiable on systems that exceed 150V to gr ound. 4. For replacement wires use conductors suitable f or 105°C. 208/230V Q5RF/PPH2RF SERIES SMALL P A CKA GE H/P W/DEMAND DEFROST 2 T ON AND 3 T ON 60HZ/SINGLE PHASE 1. Disconnect all power bef ore servicing.
19 NO TES: FIELD WIRING LEGEND: LOW V OL T AGE HIGH V OL T AGE 208/230V Q5RF/PPH2RF SERIES SMALL P A CKA GE H/P W/DEMAND DEFROST 4 T ON AND 5 T ON 60HZ/SINGLE PHASE 1. Disconnect all power bef ore servicing. 2. For supply connections use copper conductors onl y .
INST ALLER: PLEASE LEA VE THESE INST ALLA TION INSTRUCTIONS WITH THE HOMEO WNER. 7091580 Specifi cations and illustrations subject to change without notice or incurring obligations.
デバイスAcnodes Q5RF SERIESの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Acnodes Q5RF SERIESをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAcnodes Q5RF SERIESの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Acnodes Q5RF SERIESの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Acnodes Q5RF SERIESで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Acnodes Q5RF SERIESを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAcnodes Q5RF SERIESの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Acnodes Q5RF SERIESに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAcnodes Q5RF SERIESデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。