p/n 75872 Rev. D ECN-12887 M 642 05 0616 cps 642 OWNERS MANUAL for E. B. C.™ Electronic Brew Control ™ AI R P O T AN D THERMAL SERVER COFFEE BREWERS MOD EL S 1080 1082 1082XL 1086 1088 Includes: Installation Use & Care Servicing Instructions Model 1082 Brewer with optional 7752 Airpot E.
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged b y skilled personnel before le aving the factory. Upon acceptance of this shipm ent, the transportation company assumes full responsibility for its safe delivery.
TABLE OF CONTENTS SPECIFICATIONS Thank You for pu rchasing this Bloomfield Industries appliance. Proper installation, professional operation and consistent maintenance of this appliance w ill ensure that it gives you the very best performance and a long, economical service life.
FE AT U R E S AN D O P E R AT I N G CO N T R O L S Fig. 1 Fe atures & Op erating C ontrols 2 642 75872 Owners Manual E.B .C. Airpot /Thermal.
PRECAUTIONS A ND GENERAL INFOR M ATION WA RNI NG: ELECTRIC SHOCK HAZARD All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock.
INSTALLATION INSTRUCTIONS RE A D THIS CAREFULL Y BEFORE ST ARTING THE INST A LL A TION Unpack the unit. Inspec t all components f or completeness and condition. Ensure that all packing materials have been removed from the unit. Verify that the Spray Head Gasket and Spray Disk are properly installed.
INSTALLATION INSTRUCTIONS (continued) NOTE: This equipment must be installed to comply with applicable federal, state an d local plum bing codes an d ordinanc es. WARNING: ELECTRIC SHOCK HAZARD Brewer must be properly grounded to prevent possible shock hazard.
OPERATION 6 Fig. 4 Brewer Operation Diagram A. ST ART- UP For initial start-up, or if the br ew er has not been used for an extended period of tim e: ♦ Be sure spray disk and brew gasket are properly installe d in the brew head. ♦ Be sure the wa ter supply is properly connected and the water supply valve is turned ON .
OPERATION (continued) 7 WATER HEATER W ater temperature is sensed by an electronic water temperature probe inserted into the water tank. This tempera ture sign al is fed t o the control ler.
8 OPERATION (continued) ELECTRONIC FEATURES Energizing the Brewer When electric power is applied to th e unit, all the li ghts will flash four times and four beeps will sound. The unit will be OFF . Press the ON/OFF key. Four beeps will sound and all lights will flash once.
OPERATION (continued) Quality Timer is normally set for 30 minutes. It can be set for 20 minutes by moving a jumper on the controller. See page 19. After Hours™ is an energ y saving f eature. T he brewer will enter After Hours™ mode if it is not used for three hours.
BREWING COFFEE CA UTI ON: Burn Hazard Exposed surfaces of the brewer, brew chamber and airpot or se rver m ay be HOT to the touch, and can cause serio us burns. CA UTI O N: Burn Hazard To avoid splashing or over- flowing hot liquids, ALWAYS place an empty airpot or server under the brew cham ber bef ore starting the brew cycle .
CLEANING I NSTRUCTIONS 11 PROCEDURE: Clean Coffee Brewe r PRECAUTIONS: D isco nn e ct br ewer from electric po wer. Allow brewer to cool. FREQUENCY: Daily TOOLS: Mild Detergent, Clean Sof t Cloth or Sponge Bristle Brush. 1. Disconnect brew er from electric power.
SUGGESTED REMEDY Check po wer supply cord Check / reset circuit breaker Turn on an d set fo r desired temp erature. See page 1 5 Allow to cool (1012, 1040 or 1072), or allow to cool and reset hi-limit (1086, 1088) Examin e wiring & connec tors, controller, pow e r board and heating element Repair/replace as needed Adjust controller.
CAUTION ELECTRIC SHOCK HA ZAR D Live electrical circuits may be exposed while per form ing these procedures. These procedu re s are to be performed by qu alified technical personnel only.
SERVICING INSTRUCTIONS CA UTI ON Electric Shock Hazard Opening access panels or remov ing warmer plat es on this brew ma y expose uninsul ated electrical com ponents . Disconnect brewer from electrical power before removing any pa nel or warm er plate.
SERVICING INSTRUCT IONS (continued) TEMPERATURE ADJUSTMENT Unplug power cord or turn circuit breaker OFF. Remove top panel. Remov e button plug from front panel. Pull vent tube out of tank lid an d insert a thermometer of known accuracy in vent hole. Reconnect brewer to e lectr ical power.
SERVICING IN STRUCTIONS (continued ) IMPORTANT: W ater pr essure must be between 20 p.s.i and 90 p.s.i. f lowing pressure. If water pressure exceeds this value, or if water pressure varies gr eatly, a pres sure regulator must be insta l led in the water supply lin e.
SERVICING IN STRUCTIONS (continued ) 17 REPLACE SOLENOID Unplug pow er cord. Turn OFF and disconn ect w ater supply from brewer inlet fitting. Remove front pane l. Remove two screws h olding acc ess door in place. Remove access door and solenoid. Unscrew inlet fitting cap to release solenoid from door.
REPLACE HOT WATER FAUCET COIL (Symptom: Brewer drips continuously from brew head, except when faucet valve is turned OFF.) Remove t ank lid ass embly per above. Remove two hex nuts hot water coil to cover. Pull coil f rom mounting holes. Reassemble in reverse order.
SERVICING IN STRUCTIONS (continued ) 19 Fig. 19Keypad Ribbon C able Hook -Up SET CONTROLLER JUMPERS Placing the jumper across Q1 se ts Quality Time at 20 Minutes. Placing the jumper across Q2 se ts Quality Time at 30 Minutes. Removing jumpers from both Q1 or Q2 disables Quality Timer.
CA UTIO N - CH EMICA L BURN HA ZA RD Deliming chem icals are caustic. W ear ap pr op riate pr ote ct ive gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mou th. This operation should only be perfo rm e d by qualifie d an d ex- perienced service personnel.
7. Set the tank back into the bre wer. Reassemble the tank lid to the water tank. Mak e sure the gasket is properly in place, then reinstall the hold-do wn strap. 8. Reinstall wi ring to heating element and the rmostat. Reinstall the hi-lim it thermostat (if removed).
EXPLODED VIEW & PARTS LIST HOT WATER TANK ASSEMBLY 22 HOT WA TER TANK A SSEMBLY ITEM PART NO. DESCRIPTION USED ON 13 8043-5 Hold Down Strap All 14 8043-506 Nut, 8-32 SS Acorn All 16 60366 Screw, 1.
ELECTRICAL COMPONENTS ITEM PART NO. DESCRIPTION USED ON 30 82936 Switch, Rocker 125/250V 1086, 1088 31 1080-10 Keypad All 36 6407-15 Cord & Cap Assembly 1080, 1082 36t 8552-18 T erminal Strip 1086.
EXPLODED VIEW & PARTS LIST (continued) INTERNAL PLUMBING COMPONENTS 24 ITEM PART NO. DESCRIPT ION USED ON 8 8540-3 Faucet Outlet Tube Assembly All 9 8540-4 Formed Inlet Tube Assembly All 11 8572-2.
EXPLODED VIEW & PART S LIST (continued) CABINET COMPONEN TS ITEM P ART NO. D ESCRIPTION U SED ON 21 63201 Spacer .171 ID x .375 LG 1082XL 22 87192 Positioning Bracket 1082XL 33 8543-42 Spray Head .
WIRING DIAGRAM 26 KEY PA D P1 1 1 CONTRO L BOARD P2 5 POWER BOARD NEUTRAL IN VA LV E B HEA TE R B VA LV E A LIN E IN HEA TE R A 1 4 BLACK B L A C K 1 4 g a W H I T E 1 4 g a BLACK WHI TE 3 2 BLACK WHI TE INLET V AL VE .5 GPM CHAS SIS GROUND TEMPERAT URE PROBE HI LIMIT HEA TI NG ELEMENT E.
WIRING DIAGRA M ( continued) 27 MOD EL VOL TS W A TTS AMPS 10 86 1 15/ 230 3 500 1 5 10 88 1 15/ 230 3 500 1 5 642 75872 Owners Manual E.B .C. Airpot /Thermal.
PRINTED IN UNITED STATES OF AMERICA Bloo mf iel d Indu str i es, Inc . Division of Carrier Co mmercial Refrigeration In US and Can ada T elep hone: 775 -6 89-5700 Fa x: 888-4 92-2783 Fa x: 800-3 56-5142 () websi te: www .
デバイスBloomfield 1088の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bloomfield 1088をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBloomfield 1088の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bloomfield 1088の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bloomfield 1088で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bloomfield 1088を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBloomfield 1088の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bloomfield 1088に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBloomfield 1088デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。