Bloomfieldメーカー2016の使用説明書/サービス説明書
ページ先へ移動 of 28
PRINTED IN UNITED STATES OF A MERIC A p/n 73573 Rev. V ECN-12817 M651 05 0208 cps 651 OWNERS MANUAL for E-Max™ DECANTER COFFEE BREWERS MOD EL S 2012 2016 2016EX 2072 2072L 2072FR 2072FRL 2074 2074L .
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged b y skilled personnel before le aving the factory. Upon acceptance of this shipm ent, the transportation company assumes full responsibility for its safe delivery.
TABLE OF CONTENTS SPECIFIC ATIONS Thank You for purc hasing this Bloomfield Industries appliance. Proper installation, professional operation and consistent maintenance of this appliance w ill ensure that it gives you the very best performance and a long, economical service life.
FE AT U R E S AN D O P E R AT I N G CO N T R O L S 2.
WARNING: Electric Shock Hazard All servicing requiring access to non-insu lated components must be performed by qualified service personnel. Do not open any access panels wh ich require the use of tools. Failure to heed this warning can re su lt in electrical shock.
INSTALLATION INSTRUCTIONS RE A D THIS CAREFULL Y BEFORE ST A R TING THE INST A LLA TIO N UNPACKING & INITIAL INSPECTION 1. Unpack the unit. Inspec t all components for completeness and condition. Ensure that all pack ing materials have bee n rem oved from the unit.
INSTALLATION INSTRUCTIONS (continued) NOTE: This equipment must be installed to comply with applicable federal, state an d local plum bing codes an d ordinanc es. WARNING ELECTRIC SHOCK HAZARD: Brewer must be properly grounded to prevent possible shock hazard.
OPERATION IMPORTANT: All E-Max™ brewers are tested and set a t the fa ctory . If programming adjust- ments are necessary, refer to the E -Ma x™ Programming Manual (p/n/73674). To over-ride th e Br ew Wait mode , press and hold the BR EW key for 3 second s when the brewer is in Bre w Wait mode (i.
OPERATION (continued) WA RN IN G: Burn Hazard. This appliance dispenses very hot liquid. Serious bodily injury from scalding can occur from contact with dispensed liquids. C AUTION: B urn Hazard To avoid splashing or overflowing ho t liquids, ALWAYS use an empty decanter b efor e starting the brew cycle.
PROGRAMMING FEATURES AND OPTIONS 1. View Water Temperature in Tank: To view the water tem perature on the scre en, the E-Ma x™ brewer must be ON, and not brewing or in the filling mode. Press and hold the 4th key, and depress the 6th key. The actual wa ter temperature w ill be displayed for 3 seconds.
8. Clock A. Time – Battery Backup. The E-Max™ has a batter y backup system which will maintain the proper time during power failures, or when the brewer is unplugged (even for very prolonged periods of time).
OPERATION (continued) 12. View Filter Statistics: To view filter st atistics, tu rn the bre wer off. Pr ess and hold the 1st ke y (Brew), and depress the 3rd (ON/OFF) key. Total water volume will be displayed (TotalVol.). Press the 3rd k ey to view the Filter Life (F ltrLife:).
CLEANING I NSTRUCTIONS PROCEDURE: Clean Coffee Br e wer PRECAUTIONS: Disconnect bre wer from electric power. Allow brewer to cool. FREQUENCY: Daily TOOLS: Mi ld Detergent, Clean So ft Cloth or Sponge Bristle Brush 1. Dis connect bre wer from electric po w er.
FUNCTION 1. W ater enters at the inlet fitt ing of the fill solenoid (32). The s olenoid admits water via a command from the controller. N OTE: The solenoid has an inter nal strainer. To clean the s trainer: Shu t off water s upply. Unscre w the plasti c cap protruding f rom the rear of the brewer.
SERVICING IN STRUCTIONS — PLUM BING (continued) 13 ITEM DESCRI PTIO N P ART N0. USED ON 1 2 ASS EMB L Y , W A TER T AN K (120 V) 835 00 201 2 , 20 72 20 15 , 2 07 5 6 G ASK ET , T ANK LID 834 9 9 ALL 9 T ANK L ID 83 5 04 ALL 10 RET A INING CLIP , T ANK LID 8350 6 ALL 1 1 HO S E, OV ERF LO W ( 2 pc SI LI CON E 4.
SERVICING INST RUCTIONS - ELECTRIC AL FUNCTION 1. Pressing th e POWER k ey energizes the unit. The POWER LED will glow whenever the unit is ON . 2. Autom atic fill is accomp lished via a FI LL SOLENOID (32) and a WATER LEVEL PROBE (7). The probe senses ground t hrough the water in the tank.
SERVICING INSTR UCTIONS - ELECTRIC AL (continued) 15 ITEM DE S CRI PTIO N P ART N0. USED ON 3 P R O BE, TE MPE R A TUR E 83480 AL L 4 T HE R M O ST A T , HI-L IM I T SA F E TY (120 V ) 83949 2 01 2, 2.
SERVICING INSTRUCTIONS — DE -LIMING WA TER HEATER TA NK 1. Disconn e ct br e wer form the electrica l sup pl y. Turn off t he water suppl y and dis connect water suppl y from the bre wer inlet fitting. 2. Rem ove the top panel or top wa rmer section to gain access to internal components.
TROUBLESHOOTING SUGGESTIONS If the E-Max™ goes into the error diagnostic mode as outlined below , it will likely be necessa ry to reset the brew er in ord er to test individual components.
EXPLODED VIEW & PARTS LIST 18 3-WARMER IN-LINE BREWER MODELS: 2012, 2016.
EXPLODED VIEW & PARTS LIST (continued) 19.
EXPLODED VIEW & PARTS LIST (continued) 20 3-WARMER STEP-UP BREWER MODELS: 2072, 2074.
EXPLODED VIEW & PARTS LIST (continued) 21.
WIRING DIAGRA MS White #1 1 White #1 1 White #10 Red #6 Black #9 Black #9 Brown #1 # 1 # 2 # 3 White White White #1 1 Red #4 Red Blue Blue #5 Orange #3 Oran ge #7 Orange #8 Red #6 Brown #1 Blue #2 Bla.
WIRING DIAGRA MS (continued) 23 Black #16 Orange #3 B l u e # 7 B l a c k # 8 Red #14 1 2 3 4 Red #6 Brown #1 Blue # 2 Black #9 White #12 White #10 White #1 1 T ank Heater 3200 W att 240 V olt White #.
WIRING DIAGRAMS (continued) 24 IN-LINE BREWER 240 VOLT.
NOTES 25.
PRINTED IN UNITED STATES OF AMERICA Bloo mf iel d Indu stri es, Inc . Division of Carrier Co mmercial Refrigeration In US and Can ada T elep hone: 775 -689- 5700 Fa x: 888-4 92-2783 Fa x: 800-3 56-5142 () websi te: www .
デバイスBloomfield 2016の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bloomfield 2016をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBloomfield 2016の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bloomfield 2016の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bloomfield 2016で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bloomfield 2016を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBloomfield 2016の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bloomfield 2016に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBloomfield 2016デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。