Bloomfieldメーカー2086の使用説明書/サービス説明書
ページ先へ移動 of 28
PRINTED IN UNITED STATES OF A MERIC A p/n 73574 Rev. S ECN-1281 7 M652 05 0208 cps 652 OWNERS MANUAL for E-Max™ AIRPOT and THERMAL COFFEE BREWERS MOD EL S 2080 2082 2086 2086EX 2088 2088E X Includes: Installation Operation Use & Care Servicing Instructions Model 2082 Airpot Brewer with optional 7759 Airpot E-Max BREWERS are cov ered under U.
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged b y skilled personnel before le aving the factory. Upon acceptance of this shipm ent, the transportation company assumes full responsibility for its safe delivery.
TABLE OF CONTENTS SPECIFICATIONS Thank You for purc hasing this Bloomfield Industries appliance. Proper installation, professional operation and consistent maintenance of this appliance w ill ensure that it gives you the very best performance and a long, economical service life.
FE AT U R E S AN D O P E R AT I N G CO N T R OL S 2.
WARNING: Electric Shock Hazard All servicing requiring access to non-insu lated components must be performed by qualified service personnel. Do not open any access panels wh ich require the use of tools. Failure to heed this warning can re su lt in electrical shock.
INSTALLATION INSTRUCTIONS RE A D THIS CAREFULL Y BEFORE ST A RTING THE INST A LLA TION UNPACKING & INITIAL INSPECTION 1. Unpack the unit. Inspec t all com ponents for completeness and condition. Ensure that all pack ing materials have been rem oved from the unit.
INSTALLATION INSTRUCTIONS (continued) NOTE: This equipment must be installed to comply with applicable federal, state an d local plum bing codes an d ordinanc es. WARNING ELECTRIC SHOCK HAZARD: Brewer must be properly grounded to prevent possible shock hazard.
OPERATION IMPORTANT: All E-Max™ brewers are tested and set a t the facto ry . If programming adjust- ments are necessary, refer to the E -Ma x™ Programming Manual (p/n/73674). To over-ride th e Br ew Wait mode , press and hold the BR EW key for 3 second s when the brewer is in Bre w Wait mode (i.
OPERATION (continued) W ARNING: Burn Hazard. This appliance dispenses very hot liquid. Seriou s bodily injury from scalding can occur f rom co ntact with dispensed liquids. C AUTION: B urn Hazard To avoid splashing or overflowing ho t liquids, ALWAYS use an empty airpot or therm al server before starting th e brew cycle.
PROGRAMMING FEATURES AND OPTIONS 1. View Water Temperature in Tank: To view the water tem perature on the scre en, the E-Ma x™ brewer must be ON, and not brewing or in the filling mode. Press and hold the 4th key, and depress the 6th key. The actual wa ter temperature w ill be displayed for 3 seconds.
8. Clock A. Time – Battery Backup. The E-Max™ has a battery backup s ystem which will maintain the proper time during power failures, or when the bre wer is unplugged (even f or very prolonge d periods of time).
OPERATION (cont inued) 12. View Filter Statistics: To view filter stat istics, turn the brewer off . Press and ho ld the 1st k ey (Brew), and depress the 3rd (ON/OFF) k ey. Total water volume will be displayed (TotalVol.). Press the 3rd key to view the Filter Lif e (F ltrLife:).
CLEANING I NSTRUCTIONS PROCEDURE: Clean Coffee Br e wer PRECAUTIONS: Disconnect bre wer from electric power. Allow brewer to cool. FREQUENCY: Daily TOOLS: Mild Detergent, Clean So ft C loth or Sponge Bristle Brush 1. Dis connect bre wer from electric po w er.
FUNCTION 1. W ater enters at the inlet fitt ing of the fill solenoid (32). The solenoid adm its water via a command from the controller. NOTE: The solenoid has an inter nal strainer. To clean the strain er: Shut of f water supp ly. Unscrew the plastic ca p protruding from the rear of the brewer.
SERVICING IN STRUCTIONS — PLUM BING (continued) ITEM DESCRI PTIO N P ART N0. USED ON 1 2 A SSEMB L Y , WA TE R T ANK (120 V) 83500 201 2, 2072 2015 , 207 5 6 G ASKE T , T ANK LID 83499 AL L 9 T AN K L ID 83504 AL L 10 RET A INING CLIP , T ANK LID 835 06 ALL 1 1 HOSE, OV ERF LOW ( 2 pc SI LI CO N E 4.
SERVICING INST RUCTIONS - ELECTRIC AL FUNCTION 1. Pressing th e POWER k ey energizes the unit. The POWER LED will glow whenever the unit is ON . 2. Automatic fill is accomp lished via a FI LL SOLENOID (32) and a W ATER LEVEL PROBE (7). The probe senses ground through the water in the tank.
SERVICING IN STRUCTIONS - ELECTRIC AL (continued) 15 ITEM DESC R IP TI ON P AR T N0. USED ON 3 PROBE, TEMPERA TUR E 83480 A LL 4 T HERMO S T A T , H I-L IMIT S AF E TY (1 20 V) 839 4 9 2080, 20 82 5 G.
SERVICING INSTRUCTIONS — DE-LIMING HE A TER TANK 1. Disconnect br e wer form the electrica l sup pl y. Turn off the water suppl y and disc onnect water supply f rom the brewer inlet fitting. 2. Rem ove the top panel or top warmer section to gain access to internal components.
TROUBLESHOOTING SUGGESTIONS If the E-Max™ goes into the error diagnostic mode as outlined below , it will likely be necessa ry to reset the brew er in ord er to test individual components.
EXPLODED VIEW & PARTS LIST 18 AIRPOT BREWER MODELS: 2082, 2083, 2088.
EXPLODED VIEW & PARTS LIST (continued) 19 ITEM PART # DESCRI PTION QT 1 8763-1 FAUCE T HOT W ATE R 1 2 83500 83753 84010 TANK ASST 8 QT TANK ASSY 8 QT 240V TANK ASSY 8 QT DUAL VOLTAGE 1 3 83480 TH.
EXPLODED VIEW & PART S LIST (continued) 20 THERMAL BREWER MODELS: 2080, 2085, 2086.
EXPLODED VIEW & PARTS LIST (continued) 21 ITEM PART # DESCRIPTION Q 1 8763-1 FAUCET HOT WATER 1 2 83500 83753 84010 TANK ASST 8 QT TANK ASSY 8 QT 240V TANK ASSY 8 QT DU AL VOLTAGE 1 3 83480 THERMI.
WIRING DIAG RAMS MODEL 2080 & 2082 120 VOLT BREWERS AIRPOT and THERMAL 22 White #8 White #9 White #1 1 Red #3 Black #7 Black #6 Brown #1 Orange/ Black #4 Orange/ Black #5 Red #3 Bro wn #1 Blue #2 Blue #2 Black #6 White #9 White #10 White #8 14 ga .
WIRING DIAGRA MS (continued) MODEL 2086 & 208 8 120/240 VOLT BREWERS AIRPOT and THERMAL 23 Black #12 B l a c k # 4 B l a c k # 5 Red #10 1 2 3 4 Red # 3 Red # 3 Brown #1 Blue #2 Blue #2 Black #6 B.
WIRING DIAGRAMS (continued) 24 MODEL 2086EX & 2088EX 240 VOLT BREWERS AIRPOT and THERMAL.
NOTES 25.
PRINTED IN UNITED STATES OF AMERICA Bloo mf iel d Indu stri es, Inc . Division of Carrier Co mmercial Refrigeration In US and Can ada T elep hone: 775 -689- 5700 Fa x: 888-4 92-2783 Fa x: 800-3 56-5142 () websi te: www .
デバイスBloomfield 2086の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bloomfield 2086をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBloomfield 2086の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bloomfield 2086の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bloomfield 2086で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bloomfield 2086を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBloomfield 2086の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bloomfield 2086に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBloomfield 2086デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。