p/n 74415 Rev. F ECN-12888 M661 05 00615 cps 661 OWNERS MANUAL for SS1 - SERIES SA TELL ITE COFFEE BREWERS wit h ELECTRO-MECH A NICAL CONTROL and INTERNALLY HEATED SATELLITE SERVER MODEL : 9311 Includ.
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged b y skilled personnel before le aving the factory. Upon acceptance of this shipm ent, the transportation company assumes full responsibility for its safe delivery.
TABLE OF CONTENTS Thank You for purcha sing this Bloomfield Industries appliance. Proper installation, professional operation and consistent maintenance of this appliance w ill ensure that it gives you the very best performance and a long, economical service life.
FE AT U R E S AN D OP E R AT I N G CO N T R O L S 2 Fig 1. SS-1 Satellite Brewing System Features & Operating Controls 661 74415 9311 Single Satellite Brewer.
FEATURES AND OPER ATING CONTROLS (continued) Brewer Adjustable Legs Bypass Nozzle Connector Hot W ater Faucet Name plate Control Panel Brew Sw itc h Ready to Brew Indicator Stop Swi t ch Satellite Ind.
This appliance is inten ded for use in commercial e stablishments only. This appliance is inten ded to brew hot beverage, specif ically coffee, for human consumption.
5 INSTALLATION INSTRUCTIONS INSTALL LEGS The brewer is provided with adjustable legs and rubber feet. Be sure the legs are securel y screwed into th e base o f the br ew er, and that the rubber feet are properly installed. LEVEL THE UNIT The adjustable legs allow the brewer to be leveled.
INSTALLATION INSTRUCTIONS (continued) 6 CA UTIO N: Electric Shock Hazard Brewer must be properly grounded to a reliable earth ground to prevent possib le shock hazard. Do not assume a plumbing line will provide such a ground. Electrical shock may cause serious injury.
7 OPERATING INSTRUCTIONS Fig. 4 Control Panel Fig. 5 Brew Basket NOTE: Brewer will not bre w unless a satellite is properly installed. NOTE: The brew can be cancelled at any time by pressing the STOP sw itch . NOTE: DO NOT turn the VOLUME SELECT switch during a brew.
OPERATING INSTRUCTIONS (continued) 8 Fig. 6 W ater Flow D iagram BREW & BY PASS The SS-1 is a modified disp lacement brewer. For 1/2 and 1 gallon brews, there is no bypass. Water admitted into the hot water tank by the BRE W SO LENOID w ill displace a like amount of heated water through the brew head, b rew cham ber and into the satellite.
9 CLEANING INSTRUCTIONS CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brewer PRECAUTIONS: Press POW ER key to OFF. Allow brewer to cool. FREQUENCY: Dail y TOOLS: Mild Detergent, Clean So ft Cloth or Sponge Bristle Brush 1. Press POWER key to OFF. Allow brewer to cool.
10 CLEANING INSTRUCTIONS (continued) PROCEDURE: Clean Satellite PRECAUTIONS: Drain Satellite bef ore Cleaning FREQUENCY: T w ice W eekly TOOLS: Sight Glass Brush, Sanit izer Sof t Clean Cloth, Bucket 1. Remove and drain satellites. 2. Place 1 packet of Sanitizer int o 2-1/2 gallon s of wa rm tap water.
SERVICING INST RUCTIONS 11 CAUTION: SHOCK HAZARD Live electrical circuits are exposed during this procedure. Use care to avoid uninsulated electrical connectors. Adjustments to be performed by qualified technician only. NOTE: 1/8 turn = approx 10ºF (5.
SERVICING IN STRUCTIONS (continued) 12 CA UTION : SHOCK HAZARD Disconnect br ewer from electric power before opening the access panel. Adjustm ents to be perf ormed by qualified te chnic ian only. NOTE: Brewer is pre-adjusted to deliver 1/2, 1 and 1-1/2 gallons of coffee at a wate r pressure of 50 p.
SERVICING INSTRUCTIONS (continued) 13 CA UTION : SHOCK HAZARD Disconnect brewer from electric power before opening the access panel. The QUALITY TIMER flashes the SATELLIT E light at th e end of the set interval to si gnal that the coffee has lost freshness.
CA UTION - CH EMICA L BU RN HA Z A RD Deliming chem icals are caustic. W ear ap pr op riate protec t ive gloves and goggles during this procedure. Never siphon deliming chemicals or solutions by mou th. This operation should only be perfo rm e d by qualifie d an d ex- perienced service personnel.
SERVICING INSTRUCTIONS (continued) 15 10. Reinstall tank lid asse mbly into hot water t ank. Make sure the lid gasket is properly in place, then reinstall th e hold- down clamps. 11. Remove spray disks and gaskets. Rinse both brew heads with clean water.
TROUBLESHOOTING SU GGESTIONS SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY W ill not heat or brew (no lights) Brewer not plugged in or circuit breaker tripped Reconnect b rewer to electric power Reset circuit breaker Fuse blow n Check satelli te for water saturation Replac e f use W ill not brew Satellite is not in proper p osition Reinstall satellite.
17 TROUBLESHOOTING SUGG ESTIONS (continued) SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Insuff icie nt br ew volume (any one volume only) Timer out of adjustment Adjust tim e for eac h brew v olum e Timer damaged Check. Replace if needed Volume select switch damaged Check.
MODEL 9311 EXPLODED VIEW 18 661 74415 9311 Single Satellite Brewer.
MODEL 9311 PARTS LIST 19 661 74415 9311 Single Satellite Brewer.
20 9311 WIRING DIAGRA M 661 74415 9311 Single Satellite Brewer.
21 9340 SATELLITE EXPLODED VIEW & PARTS LIST L1 NEUT . 45 W SCHEMA TI C P/N 73 061 MODEL VOLTS WATT S 9340 120 45 SATELLITE ASSEMBLY 9340 120V ITEM PART NO.
PRINTED IN UNITED STATES OF AMERICA Bloo mfiel d Indu stri es, Inc. Division of Carrier Co mmercial Refrigeration In US and Can ada T el ephone: 775 -689- 5700 Fa x: 888-4 92-2783 Fa x: 800-3 56-5142 () websi te: www .
デバイスBloomfield 9311の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bloomfield 9311をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBloomfield 9311の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bloomfield 9311の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bloomfield 9311で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bloomfield 9311を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBloomfield 9311の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bloomfield 9311に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBloomfield 9311デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。