W ARNING : Improper installat ion , adjust ment , alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional informat ion consult a qualified inst aller , service agency or t he gas supplier .
2 6 720 607 030 This well engineered, gas water heater has all the fea- tures a water heater should have: It operates on the principle of heating water instantaneously “on demand”. When a hot water faucet is opened, cold water flows through the coils of the heat exchanger in the Aquast ar.
3 6 720 607 030 M I N I M U M I N S T ALLA TI O N C LE ARAN C E S F R OM C O M B U S TI B LE A N D N O N C OM B U STI B LE MA TE R IALS F OR AL COVE O R C L O SET I N S T ALLA TIO N S FR ONT VI EW SI .
4 6 720 607 030 G EN E RAL R ULE S T O FOLL OW FOR SAFE OPE R A TI ON 1. Y ou should follow these instructions when you install your heater . In the United States: The installation must conform with local codes or , in the absence of local codes , the National Fuel Gas Code ANS I Z223.
5 6 720 607 030 Fig. 1 - Water heater drain plug WARNING: Flammable materials, gasoline, pressurized containers, or any other items or articles that are potent ially fire hazards must NO T be placed on or adjacent t o t he heater . The appliance area must be kept free of all combustible materials, gasoline and other flammable vapors and liquids.
6 6 720 607 030 Expansion and contraction of piping due to changing water temperature in the pipes imparts movement to the heater which, if mounted directly to a brittle, friable board, such as plasterboard, can cause failure of mounting.
7 6 720 607 030 V ent pipe connection. WARN I NG: Do not reduce t he vent pipe size. See Fig . 4 for high altitude installat ions The heater must be vented to the outside following all local ordinances and specifications for installing a gas appliance vent or c himney .
8 6 720 607 030 MASON RY CH IM NE Y : Masonr y c himneys shall be built and installed in accordance with NF PS 2 1 1 or local codes. A minimum 5” diameter gas vent pipe (met al double wall T ype B ), or an approved clay flue liner or a listed chimney lining system must be used when venting into a naturally drafting, internal masonry c himney .
9 6 720 607 030 T o check t he draft : Close all doors and windows to the outside. T urn on all appliances that force air out of the building . These include all exhaust/ventilation fans, furnaces, clothes dryers, wood burning stoves, etc. Open all doors between the AquaStar and these other appliances.
10 6 720 607 030 GAS LINE SIZING -It is strongly recommended that the Natural Gas pipe be Black Iron pipe the entire distance from the outside meter to the inlet of t he Aquast ar regulat or . 1 /2” Black Iron pipe up t o 1 0 feet , 3/ 4 ” Black Iron pipe up to 4 0 feet and 1 ” Black Iron pipe up to 1 50 feet distances.
11 6 720 607 030 GAS PIPING, CONNECTIONS and Gas Regulator Before connecting the gas supply, c heck the rating plate on the right side of the front cover to be sure that the heater is rated for the same gas to which it will be connected.
12 6 720 607 030 W A TE R CON NECTIONS Install the heater centrally in the building if possible and make hot water piping runs as short as possible When facing the heater , the cold water inlet will be on the right and the hot water outlet on the left.
13 6 720 607 030 LIGHTING INSTRUCTIONS (as seen on front cover of heater) 1. S T O P! Read the safety information above on this plate. 2. The Gas valve must be turned off by sliding the gas valve button to the far left under the OFF ( ) mark. 3. W ait five (5) minutes to clear out any gas .
14 6 720 607 030 T o clean t he pilot burner and/ or t he pilot orifice : T urn off the gas at the unit. Remove the cover of the heater . T o do so, pull off the temperature adjustment knob and unscrew and remove the plastic collar and unscrew the central screw located at the bottom of the front cover .
15 6 720 607 030 3. Poor thermocouple connection at the electromagnet Note : Electromagnet is part #8 7072 0 1 01 2 l ocated on the right side of the gas valve behind the piezo push-button assembly . Check the tightness of the thermocouple connection nut at the electromagnet: The Electro-magnet connection is a large aluminum 1 7mm hex head nut.
16 6 720 607 030 5. Crossover in household plumbing The AquaStar burner activates when there is sufficient water pressure drop in the AquaStar water valve assembly — i.e. when a hot water faucet is opened. If there is a crossover in the plumbing, the necessary pressure drop in the AquaStar will be insufficient, or totally eliminated.
17 6 720 607 030 H O T WA T E R TE M PE RA TU R E F LUCTU A T E S / U N IT DEA C T IV A T ED 1 . Unbalanced pressure in waterlines The added restriction caused by the Aquastar in the hot water system can result in uneven pressures between the cold and the hot.
18 6 720 607 030.
19 6 720 607 030 Fig. 1 2 - Diagram of AquaStar 1 25 B 1 . Heat exchanger 2. Pilot assembly 3. Burner manifold gas pressure test nipple 4. Main gas burner 5. Pilot gas tubing 6. Gas valve 7 . Pressure tap screw location 8. Gas control slide 9. Piezo igniter 1 0 .
20 6 720 607 030 Fig. 1 3 - I NTER I O R C OMP ON E NTS DIAGRAM AND P ARTS LIST.
21 6 720 607 030 Fig. 1 3 INTERIOR COMPONENTS DIAGRAM AN D P ARTS LIST 1 25B 1 Cover 8 705 421 025 2 Temperatu re adjustment knob 8 702 000 111 3T e m p era tur e ad j ustment co l la r 8 700 403 008 .
22 6 720 607 030 LI M ITE D W AR R ANT Y Aquast ar 06.03 General Aquastar water heaters are warranted by the Manufacturer (B O SC H) through C ontrolled Energy C orp.
23 6 720 607 030 Fig. 1 4 - Flow chart of Aquastar 1 25 B.
Replacement Parts available from North American Distributor CONTROLLED ENERGY CORP . 340 Mad River Park W ait sfield, V ermont 05673 Phone 800-642-31 1 1 Fax (802) 496-6924 ww w .
デバイスBosch 125B LPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bosch 125B LPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBosch 125B LPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bosch 125B LPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bosch 125B LPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bosch 125B LPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBosch 125B LPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bosch 125B LPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBosch 125B LPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。