PROFESSIONAL INSTALL ATION IS HIGHLY RECO MMENDED Manufactured by National Steelcrafters of Oregon, Inc. DBA Breckwell Hea r th Products Eugene, Oregon Grand Prairie, Texas • Warning: If your appliance is not properly installed a house fire may result.
Thank you for purchasing the Breckw ell Pellet Burning Stove. You are now prepared to burn wood in the most efficient, convenient way possible. To achieve the safest, most efficient and most enjoyable performance from your stove, you must do three things: 1) Install it properly; 2) Operate i t correctly; and 3) Maintain it regularly.
• Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer. • Keep foreign objects out of the hopper. • Never use gasoline, gasoline - t ype lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in this stove.
INTRODUCTION ----------------------------------------------------------------------------------- ---------- 2 SAFET Y PRECAUTIONS ----------------------------------------------------------------------.
FREESTANDING Width: 29 1/8” Height: 3 0 1/8” Depth: 22 5/8” Weight: 300 lbs. Flue size: 3” or 4” Hopper Capacity: Up to 70 lbs. (This can vary widely depending on pellet size, length, and diameter) EPA status: exempt Burn rate: 1 lb. to 5.5 lbs.
COMBUSTION AIR SUPPLY For a mobile home installation the stove must be connected to an outside source of combustion air. A 2” inside diameter metallic pipe, either flexible or ri gid, may be attached to the inlet at the stove’s rear (refer to figures 5 & 6).
Equivalent Vent Length (EVL) The longer the run of pipe in your installation (both with insert and freestanding ), the more restriction there is in the system. Ther efore, larger diameter pipe should be used. • Use 4” pipe if you have more than 15 feet of Equivalent Vent Length.
A. VERTICALLY WITH NEW CHIMNEY SYSTEM (Refer to Figure 9) NOTE: Follow L - Vent chimney manufacturer’s instructions. OPTION: To achie ve a center vertical installation a 45º elbow and a clean - out tee can be used to offset the pipe from the exhaust outlet to the rear center of the stove.
C. VERTICALLY INTO EXISTING MASONRY FIREPLACE NOTE: Follow L - Vent chimney manufacturer’s instructions. 1. Have the masonry chimney inspected by a qualified chimney sweep or installer to determine its structural condition. 2. You will need a pipe length equal to the chimney height from the hearth.
INSERT INSTALLATIONS Insert installations must be vented with 3” or 4” pipe. Pipe may be single wall stainless steel flexible pipe. Vent may terminate within chimney beyond a blanking plate or extend to the chimney top. See “ COMBUSTION AIR SUPPLY ” for outside air access information.
B. WHEN VENT PIPE EXTENDS TO CHIMNEY TOP ( Refer to Figure 15) 1. You will need a pipe length equal to the chimney height (from hearth) plus 6 inches. If outside combustion air is to be used, you will need a pipe length (see “ COMBUSTION AIR SUPPLY ” ) equal to the chimney height plus 12 inches.
D. AS A BUILT - IN FIREPLACE Figures 16 and 17 describe a P2000 installation vented into either a special chase built outside an outer wall or a fa lse inside wall.
E. INSTALLATION IN TO A FACTORY BUILT (METAL) FIREPLACE (refer to figure 18) When installing into a factory built fireplace, the firebox must accept the insert without modification other than removing bolted or screwed togethe r pieces such as smoke shelf/deflectors, ash lips, screen or door tracks and damper assemblies.
PROPER FUEL THIS S TOVE IS APPROVED FOR BURNING PELLETIZED WOOD FUEL ONLY! Factory - approved pellets are those ¼” or 5/16” in diameter and not over 1” long. Longer or thicker pellets sometimes bridge the auger flights, which prevents proper pellet feed.
a. ON/OFF SWITCH • When pushed the stove will automatically ignite. No other firestarter is necessary. The igniter will stay on for at least 10 and up to 15 minutes, depending on when Proof of Fire is reached. The fire should start in about 5 to 7 minutes.
IF STOVE RUNS OUT OF PELLETS The fire goes out and the auger motor and blowers will run unti l the stove cools. This will take 30 to 45 minutes. After the stove components stop running the “On/Off” and the BAR GRAPH lights stay on for 10 minutes.
OPERATING THE STOVE USING A THER MOSTAT A thermostat may help you maintain a constant house temperature automatically. A millivolt thermostat is required. A fixed wall mount or Breckwell’s hand held model can be used. The control panel can be set up two ways to operate your stove in ther mostat mode.
OPERATING SAFETY PRECAUTIONS PLEASE READ THIS! a. If you notice a smoldering fire (burnpot full but no visible f lame) AND a heavy smoke buildup in firebox, immediately TURN OFF the stove, but DO NOT unplug it. Do not open the door, change the damper setting or tamper with any controls on the stove.
FAILURE TO CLEAN AND MAINTAIN THIS UNIT AS INDICATED CAN RESULT IN POOR PERFORMANCE AND SAFETY HAZARDS . NEVER CLEAN WHEN HOT. NOTE: Inspect burn pot periodically to see that holes have not become plugged, if so, clean thoroughly. ASH REMOVAL Ashes should be placed in a metal container with a tight - fitting lid.
VACUUM USE If a vacuum is used to clean your unit, we sug gest using a vacuum designed for ashes. (We recommend LoveLess Ash Vac, 1 - 800 - 568 - 3949 Ext. #27) Some regular vacuums and shop vacs leak ash into the room. Your vacuum or shop vac may have a special filter or bag available to eliminate this leakage.
CHIMNEY CLEANING a. Creosote Formation – When any wood is burned slowly, it pro duces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue or a newly started fire or from a slow - burning fire.
MAINTENANCE 22 FIGURE 28 P2000I.
When your stove acts out of the ordinary, the first reaction is to call for help. This guide may save time and money by enabling you to solve simple problems yourself. Problems can be caused by to only five factors: 1) poor fuel; 2) poor operation or maintenance; 3) poor installation; 4) component failure; 5) factory defect.
STOVE SHUTS OFF AND THE # 3 LIGHT FLASHES Possible Causes: Possible Remedies: (Unplug stove first when possible) 1. The hopper is out of pellets. Refill the hopper.
STOVE FEEDS PELLETS, BUT WILL NOT IGNITE Possible Causes: Possible Remedies: 1. Air damper open too far f or ignition. Push the air damper in closer to the side of the stove for startup. In some situations it may be necessary to have the damper completely closed for ignition to take place.
STOVE WILL NOT FEED PELLETS, BUT FUEL FEED LIGHT COMES ON AS DESIGNED Possible Causes : Possible Remedies: 1. F2 fuse on control board blew Remove the control board. On the back there are two fuses. The one closer to the edge is the F2 fuse. If it appears to be bad, replace it with a 5 Amp 250 Volt fuse.
• GLASS “SOOT’S” UP AT A VERY FAST RATE • FLAME IS LAZY, DARK, AND HAS BLACK TIPS • AFTER STOVE HAS BEEN ON FOR A WHILE, THE BURNPOT OVERFILLS Possible Causes: Possible Remedies: 1. Stove or vent pipe is dirty, which r estricts airflow through the burnpot.
HIGH LIMIT SWITCH KEEPS TRIPPING Possible Causes: Possible Remedies: 1. The convection blower is overheating and tripping the internal temperature shutoff. Try lubricating the co nvection blower. Put 1 - 2 drops of SAE 20 oil in each of the two oiling ports.
ELECTRICAL DIAGRAM FIGURE 30 29.
Conta ct an Authorized Breckwell Pellet Stove Dealer to obtain any of these parts. Never use substitute materials. Use of non - approved parts can result in poor performance and safety hazards.
デバイスBreckwell P2000の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Breckwell P2000をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBreckwell P2000の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Breckwell P2000の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Breckwell P2000で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Breckwell P2000を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBreckwell P2000の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Breckwell P2000に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBreckwell P2000デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。