• AC Powered Ionization Smoke Alarm with Battery Back-Up and Silence Featur e Cat. 4120SB Input: 120V AC, 60Hz, 0.5A AC Powered Ionization Smoke Alarm with Battery Back-up Cat.
INSIDE THIS MANUAL Where T o Install Smoke Alarms . . . . . . . . . 1 Where Not T o Install Smoke Alarms . . . . . . 3 Important! Read Before Y ou Install This Smoke Alarm . . . . . . . . . . . . . . . . . . . 5 Understanding the Indicator Lights and Alarm Horn Patter ns .
1 Where T o Install Smoke Alarms Installing Smoke Alarms in Single-Family And Multi-Family Residences The National Fire Pr otection Association (NFP A), recommends one smoke alarm on every fl oor , in every sleeping ar ea, and in every bedroom. In new construction, the smoke alarms must be AC power ed and interconnected.
2 More specifically , install smoke alarms: • On every level of your home, including finished attics and basements. • Inside every bedroom, especially if people sleep with the door partly or completely closed. • In the hall near every sleeping area.
3 reliable early warning protection for those areas separated by a door from the areas protected by the r equired smoke alarms. For this reason, it is recommended that the householder consider the use of additional smoke alarms for those areas for increased protection.
4 Avoiding Dead Air Spaces “Dead air” spaces may prevent smoke from reaching the smoke alarm. T o avoid dead air spaces, follow the installation recommendations below . On ceilings, install smoke alarms as close to the center of the ceiling as possible.
5 Important! Read Before Y ou Install This Smoke Alarm Read “Where T o Install Smoke Alarms” and “Where Not T o Install Smoke Alarms” befor e beginning. This unit monitors the air , and when smoke r eaches its sensing chamber , it alarms. It can give you mor e time to escape before fir e spreads.
6 CAUTION ! Connect this unit ONL Y to other compatible units. See “How T o Install and Inter connect This Smoke Alarm” for details. Do not connect it to any other type of alarm or auxiliary device. Connecting anything else to this unit may damage it or pr event it fr om operating properly .
7 Important Installation Parts The Mounting Bracket : T o remove the mounting bracket from the smoke alarm base, hold the smoke alarm base firmly and twist the mounting bracket off. The mounting bracket installs onto the junction box. It has a variety of screw slots to fit most boxes.
8 T o Lock The Battery Compartment IMPORT ANT! Do not lock the battery compartment until you have activated the battery and tested the battery back-up. 1. Activate the battery back-up by removing the “Pull to Activate Battery Back-Up” tab. 2. Push and hold test button until the alarm sounds: 3 beeps, pause, 3 beeps, pause.
9 4. T o relock the battery compartment, close the battery door and reinsert locking pin in lock. 5. Reconnect the power connector to the back of the smoke alarm, reattach the smoke alarm to the mounting bracket, and restor e the power . IMPORT ANT! When replacing the battery , always test the smoke alarm before relocking the battery compartment.
10 How T o Install This Smoke Alarm This unit is designed to be mounted on any standard wiring junction box up to a 4-inch diagonal size, on either the ceiling or wall. Read “Where to Install” and “Where Not T o Install” smoke alarms before you begin installation.
11 Installing a Single (Stand-Alone) Smoke Alarm T ools you will need: Standar d/Flathead screwdriver DANGER ! ELECTRICAL SHOCK HAZARD. T ur n off power to the area where you will install this unit at the circuit breaker or fuse box before beginning installation.
12 Interconnecting Multiple Smoke Alarms Interconnected units can pr ovide earlier warning of fire than stand-alone units, especially if a fir e starts in a remote ar ea of the dwelling.
13 Interconnecting Multiple Smoke Alarms T o install and interconnect multiple alarms: 1. Remove mounting bracket from the base. Position screw slots on mounting bracket over screws in the junction box. Tighten screws. 2. Strip off about 1/2” (12 mm) of the plastic coating on the orange wire on the power connector .
14 IMPORT ANT! Cat. 4120SB Only: During installation, if you accidentally press the Silence button, the alarm will “chirp” once a minute for up to 15 minutes and the T est featur e will be temporarily disabled. This is normal. The “chirping” will stop once the alarm returns to normal operation.
15 IMPORT ANT! Most carbon zinc batteries have an average service life of 1 year; most alkaline batteries have an average service life of 1-2 years; most Lithium batteries have an average service life of 6-10 years. Actual service life depends on the smoke alarm and the environment in which it is installed.
16 Cat. 4120SB Only— Using The Silence Feature The silence feature on this unit can temporarily quiet an unwanted alarm for several minutes. CAUTION ! The silence feature does not disable the unit—it makes it temporarily less sensitive to smoke.
17 Protecting Y our Family From Fire Putting up smoke alarms is just one step in protecting your family fr om fires. Y ou must also reduce the chance a fir e will start in your dwelling, and have a plan for escaping safely if one does.
18 What T o Do In Case Of Fire • Don’t panic; stay calm. Follow your escape plan. Y our safe escape may depend on thinking clearly and remembering what you have prac- ticed. • Get out of the dwelling as quickly as possible. Don’t stop to get dr essed or collect anything.
19 T roubleshooting DANGER ! ELECTRICAL SHOCK HAZARD. Always TURN OFF POWER before checking connections or disconnecting any smoke alarm! If you still have questions after reading this manual, please call Consumer Af fairs, Monday-Friday , 7:30 am-5pm (Central Time): 1-800-323-9005.
20 Special Compliance Considerations W ARNING! W ARNING! W ARNING ! This unit alone is not a suitable substitute for complete fi re detection systems in places housing many people—like apartment bu.
21 Limitations Of Smoke Alarms Smoke alarms have played a key role in r educing deaths resulting fr om home fires worldwide. However , like any warning device, smoke alarms can only work if they are pr operly located, installed, and maintained, and if smoke reaches them.
22 10-Y EAR LIMITED W ARRANTY Coverage: BRK Brands, Inc. warrants its enclosed smoke alarm to be free from defects in materials and workmanship under normal use for a period of ten years from the date of purchase. During the first year after the date of purchase, BRK Brands, Inc.
デバイスBRK electronic M06-2016-007の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
BRK electronic M06-2016-007をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBRK electronic M06-2016-007の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。BRK electronic M06-2016-007の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。BRK electronic M06-2016-007で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
BRK electronic M06-2016-007を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBRK electronic M06-2016-007の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、BRK electronic M06-2016-007に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBRK electronic M06-2016-007デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。