ページ先へ移動 of 4
MODEL • 114 ® Page 1 W ARNING W ARNING – T O REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJUR Y T O PERSONS, OBSERVE THE FOLLO WING: 1. All electrical work must be done in accordance with local and/ or National Electrical Code as applicable. For saf ety , this prod- uct must be grounded.
MODEL • 114 ® Page 2 FIELD CONVERSION T O 120 V .A.C. If a 120 V .A.C. circuit is to be used, make wiring changes as f ol- lows: 1. Disconnect white wire from heater element terminal “2” and connect it to terminal “4.” The heater will no w operate at 120 V .
MODEL • 114 ® Page 3 WIRE THE UNIT W ARNING: Disconnect power at service entrance bef ore wir- ing this product. 1. Run electrical power cable to installation location. Provide two feet of slack to allow heater to be pulled out far enough to re- move top cover for cleaning or servicing.
MODEL • 114 ® Page 4 KEY P A RT NO. NUMBER P ART DESCRIPTION 1 99522899 Cover (White) 2 99522400 Cycling Ther mal Overload Limit Switch 3 99521763 Thermal Fuse 4 99521765 Motor 5 99020130 Blower Wh.