AdmiralメーカーADM8IB - 10080020の使用説明書/サービス説明書
ページ先へ移動 of 19
Read these instructions before operating the machine Lire ce manuel avant d’utiliser la machine Bitte lesen Sie diese Anleitungen, bevor Sie die Maschine in Gebrauch nehmen MOD EL: COUNTRY ADM8IA - .
TABLE OF CONTENTS ADMIRAL 86038270 05/22/07 1 Data Log/Table of Contents .............. 1 Safety Instructions ............................ 2 Controls ............................................ 3-5 Operations ........................................ 6-11 Troubleshooting .
SAFETY INSTRUCTIONS ADMIRAL 86038270 05/22/07 2 IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precaution must always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE. This machine is for commercial use.
CONTROLS/COMPONENT LOCATIONS ADMIRAL 86038270 05/22/07 3 1. Main Handle. Used to pull and maneuver machine. 2. Handle Adjustment. Used to adjust height of handle. 3. Electrical Cord. 4. Solution Switch. Turns on pump. Continuous position (bottom) activates electro-valve to dispense solution to floor through jets.
CONTROLS/COMPONENT LOCATIONS ADMIRAL 86038270 05/22/07 4 1. Solution Accessory Tool Hookup. Used for various auxiliary cleaning tools. 2. Vacuum Hose Door. Used to connect various auxiliary 1 ½ inch cleaning tool vacuum hoses. 3. Brush Height Adjustment.
CONTROLS/COMPONENT LOCATIONS ADMIRAL 86038270 05/22/07 5 1. Solution Intake Cover. 2. Vacuum Intake Cover. 3. Float Shut-Off. 4. Clean-Out Opening. 5. Pour Spout.
FILLING OPERATIONS ADMIRAL 86038270 05/22/07 6 FILLING THE ADMIRAL NOTE: Use clean bucket of water to fill solution tank Do not put defoamer, solv ents, spotter or prespray chemicals in the solution tank . Do not allow water to spill into vacuum motor inlet.
OPERATIONS ADMIRAL 86038270 05/22/07 7 Remove electrical cord and literature from recovery tank. Fill solution tank (see filling instructions page 6). Adjust brush to proper setting. Note: For good operation the brush must skim the carpet. If circuit breaker trips raise brush to prevent damage to motor or carpet.
OPERATIONS ADMIRAL 86038270 05/22/07 8 Select continuous setting to start solution spray or select intermittent setting to enable use of trigger switches to start solution spray.
CLEANING PROCEDURE ADMIRAL 86038270 05/22/07 9 Release intermittent trigger switches or turn off continuous setting on solution switch approximately 1 foot before ending cleaning pass. Push down on handle to raise vacuum shoe and brush before moving to the next cleaning pass.
CLEANING PROCEDURE ADMIRAL 86038270 05/22/07 1 0 To speed drying, use a Windblower ™ fan. Empty recovery tank by releasing dump hose. Use a hose with cold water to clean out the recovery tank.
ACCESSORY TOOL USAGE ADMIRAL 86038270 05/22/07 11 Turn on vacuum motor switch and set solution switch to intermittent position. Note: Be sure brush switch is in off p osition and brush is in storage position. Squeeze handle on accessory tool to begin cleaning.
TROUBLESHOOTING CHART ADMIRAL 86038270 05/22/07 1 2 PROBLEM CAUSE SOLUTION No Power, Nothing Runs 1. Is the cord plugged in. 2. Circuit breaker tripped in building. 3. Faulty switch. 4. Faulty power cord or pigtail. 1. Plug in cord. 2. Reset breaker 3.
ADMIRAL 86038270 05/22/07 1 3 THIS PAGE LEFT INTENTIONALLY BLANK.
WIRING DIAGRAM ADMIRAL 86038270 05/22/07 1 4 86268290 PRV NO. 88229 86268460 PRV NO. 88333 86268430 PRV NO. 88323 86268370 PRV NO. 88276 FILTER 86003650 PRV NO. 34362 86268430 PRV NO. 88323 86268430 - PRV NO. 88323 86238840 PRV NO. 41356 86238830 PRV NO.
MAINTENANCE ADMIRAL 86038270 05/22/07 15 PERIODIC MAINTENANCE Twice a month, flush a white vinegar solution (One quart vinegar to two gallons of water) or anti-browning solution (mixed as directed) through the extractor. This will prevent build-up of alkaline residue in the system.
MAINTENANCE ADMIRAL 86038270 05/22/07 16 ! WARNING: ONLY QUALIFIED MAI NTENA NCE PERSONNEL ARE T O PERFORM THE FOLLOWING REPAIRS. VACUUM MOTOR REPLACEMENT 1. Turn off all switches and unplug machine. 2. Remove recovery tank. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame.
MAINTENANCE ADMIRAL 86038270 05/22/07 17 ! WARNING: SOLUTION PUMP REPLACEMENT 1. Turn off all switches and unplug the ma chine. 2. Remove recovery tank. 3. Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame.
TECHNICAL SPECIFICATIONS ADMIRAL 86038270 05/22/07 18 POWER TYPE ELECTRICAL: 230-240 V, 7 A, 50 HZ ELECTRIC VACUUM MOTOR: (1) –3 stage, 1 hp, 99 cfm (2.80 cubic meters/min.) Waterlift – 117” (297cm) BRUSH: (1) 15” (38.1 cm.) SOLUTION PUMP: 100 PSI, diaphragm style, internal bypass SOLUTION CAPACITY: 8 gallons (30.
デバイスAdmiral ADM8IB - 10080020の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Admiral ADM8IB - 10080020をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAdmiral ADM8IB - 10080020の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Admiral ADM8IB - 10080020の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Admiral ADM8IB - 10080020で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Admiral ADM8IB - 10080020を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAdmiral ADM8IB - 10080020の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Admiral ADM8IB - 10080020に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAdmiral ADM8IB - 10080020デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。