NOTE: Read the entire instruction in manual applicable to specific unit before starting the installation. This symbol → indicates a change since the last issue.
I. INSPECT PACKAGE AND CHECK EQUIPMENT Inspect contents of packaged humidifier. File claim with shipping company prior to installation if shipment is damaged or incom- plete. The package should contain: 1. Humidifier and media assembly 2. Humidistat 3.
VI. INSTALL DRAIN LINE 1. Use 1/2- or 5/8-in. vinyl tubing (field supplied) to connect drain on bottom of humidifier housing to an open drain. 2. Use supplied worm clamp to hold drain tubing in position over drain fitting outlet. CAUTION: Unit may leak if drain tubing is misapplied.
II. SELECT LOCATION (SEE FIG. 5.) Humidifier must be installed on supply plenum only. If furnace has air conditioning coil, be sure humidifier does not interfere with coil ends. Remember to provide clearance for maintenance and evaporator pad removal.
INSTALLATION OF HUMBBSFP1016-A-- FAN POWERED HUMIDIFIER Bryant’s HUMBBSFP1016-A-- fan powered humidifier can only be installed on the supply plenum of a forced-air system. This unit requires an external 115-vac (fused) plug-in receptacle near the equipment for proper operation.
IV. MOUNT THE HUMIDIFIER 1. Attach foam tape to back of mounting flange (exclude the off-set edge). 2. Hook off-set edge over opening cut in plenum. 3. Place humidifier in plenum aligning screw holes with flange. 4. Align, level, and tighten all screws for air tight seal.
INSTALLATION OF HUMBBSBP2017-A-- BYPASS HUMIDIFIER Bryant’s HUMBBSBP2017-A-- bypass humidifier can be installed on either the supply or return plenum of a forced air system. This unit requires an external bypass duct between the supply- and return-air ductwork.
5. Attach transfer tube to solenoid valve and insert free end into inlet fitting on top of unit housing. 6. Attach bridge rectifier to solenoid valve. 7. Insert sheet metal screws into lower holes in plenum, pre-drilled using template. 8. Tighten screws until heads protrude approximately 3/16-in.
II. SELECT LOCATION (SEE FIG. 14.) Humidifier may be installed on either supply or return plenum. If furnace has air conditioning coil, be sure humidifier does not interfere with coil ends. Remember to provide clearance for maintenance and evaporator pad removal.
VIII. INSTALL HUMIDISTAT AND COMPLETE WIRING 1. Mount humidistat on inside wall or return-air duct in accordance with section INSTALLATION OF HUMIDIS- TAT on page 10. NOTE: Wiring must comply with national electrical code and any local codes or ordinances that may apply.
II. DUCT MOUNTING (LOW VOLTAGE) 1. Locate humidistat at least 8 in. upstream of humidifier in return-air duct. If mounting near elbow area, keep device 6 in.
V. OPERATION When relative humidity falls to humidistat set point, the humidistat switch makes contact and starts humidifier. In some central unit humidifier systems, furnace fan must be operating before humidi- fier will start. An increase in relative humidity above set point will stop humidifier.
デバイスBryant HUM-56-1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bryant HUM-56-1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBryant HUM-56-1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bryant HUM-56-1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bryant HUM-56-1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bryant HUM-56-1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBryant HUM-56-1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bryant HUM-56-1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBryant HUM-56-1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。