BunnメーカーAFPO-3の使用説明書/サービス説明書
ページ先へ移動 of 25
AFPO-2 AFPO-2 SL AFPO-3 AFPO-3 SL F L AV O R IN P U T 1 2 W A T E R IN P U T RE FI LL M A I N PO W E R 2 1 1 2 3 3 3 FLA V O R OU T P U T F LA V O R O U T PU T WA T E R OU T PU T FL A V O R O U T P U .
2 41093 030912 BUNN-O-MA TIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) Airpots, thermal carafes, decanters, GPR servers, iced tea/coffee dispensers, MCP/MCA pod brewers thermal ser vers and Thermofresh servers (mechanical and digital)- 1 year parts and 1 year labor .
3 USER NOTICES All notices on the equipment are written for your protection. All notices are to be kept in good condition. Replace any unreadable or damaged labels. CONTENTS User Notices ................................................................
4 CLEANING RECOMMENDED WEEKL Y CLEANING: This should be done in conjunction with the recommended weekly cleaning of your machine. The Hoppers must be empty before starting. 1. Prepare a 1 gallon cleaning solution consisting of 1 gallon of hot water and a sanitizing cleaner which contains 3-5% chlorine based sanitizer .
5 F LA VO R INPUT 1 2 W AT ER INPU T REFILL MAIN POWE R 2 1 1 2 3 3 3 FLA VO R OUT P UT FLA VO R OUT P UT W AT ER OUTP UT FLAVO R OUTP UT WA T ER OUTP U T WAT ER OUT P UT Mix ratio (water/flavor) Time for FLA VOR OUTPUT (1/2 cup) Time for W A TER OUTPUT (1 cup) 1+1 assume 20 sec.
6 FLA VOR INPUT 1 2 WAT E R INPUT REFILL MAIN POWER 2 1 1 2 3 3 3 FLA VOR OUTPUT FLA VOR OUTPUT WAT E R OUTPUT FLA VOR OUTPUT WAT E R OUTPUT WAT E R OUTPUT OPERA TING CONTROLS A. MAIN POWER ON/OFF The main power ON/OFF switch is located on the right of the front panel just above the power cord.
7 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic T echnical Service Department.
8 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE 6. Main ON/OFF switch 7. Probe box LOW/OFF/HIGH switch - es 8. Circuit board 9. Vacuum switch 10. Vacuum/Supply pump 11. Pump (flavor) start switches 1. No water 2. Needle valve 3. Solenoids 1. Motor overheat REMEDY Refer to Service - Main ON/OFF Switch for testing procedure.
9 FL A V O R INPU T 1 2 WAT ER IN P U T R EF IL L M AI N PO W E R 2 1 1 2 3 3 3 F LA VOR O U T P UT FL A V O R O UT P U T W AT E R O UT P U T FL A VO R OU T P U T WA TER OU T P U T W AT ER O UT P U T SERVICE This section provides procedures for testing and replacing various major components used in this dispenser should service become necessar y .
10 J4 J1 J2 J3 OF F O N OF F O N OF F O N OF F O N SERVICE CIRCUIT BOARD FIG. 2 CIRCUIT BOARD P1520 Location: The circuit board is located inside the autofill box, mounted on the right side of the solenoid mounting bracket under the switch panel. T est Procedure: 1.
11 FLAVOR INPU T 1 2 WATER INP UT REFILL MAI N POW ER 2 1 1 2 3 3 3 FLAV OR OUTPUT FLAV OR OUT PUT W ATER OUTPUT F L A VOR OUT PUT W A T ER OUT PUT WATER OUT PUT SERVICE Location: The fuse holder is located on the lower right front of the autofill box just to the left of the power cord.
12 FLAVOR INPU T 1 2 WATER INP UT REFILL MAI N POW ER 2 1 1 2 3 3 3 FLAV OR OUTPUT FLAV OR OUT PUT W ATER OUTPUT F L A VOR OUT PUT W A T ER OUT PUT WATER OUT PUT P1522 FIG. 7 MAIN ON/OFF SWITCH TERMINALS BLKfromFuseHolder BLKtoSolenoid(Water) Switch #2 AFPO-2 & 3 MAIN ON/OFF SWITCH FIG.
13 BU N N ® Mov ing P a rts . D o no t op e ra t e unit w ith this pa ne l rem oved. Ris k Of Ele ct r ica l Sho ck . D iscon nec t po w er befor e ser vi ci ng u nit. CH ARG E Type R22, Am ou nt _ _ OZ. Design Pr ess ur es: High _ _ L o w _ _ Suctio n Pr es su re _ _ Probe Boxes: 1.
14 FLA VO R IN PU T 1 2 W A T E R IN P UT R EF ILL M AIN PO W E R 2 1 1 2 3 3 3 FLA V O R O UTP UT FLA VO R O U TP UT W A T ER O U TP UT FLA VO R O UTP U T W A T ER O UTP U T W A T ER O UTP U T SERVICE (cont.
15 FLAVOR INPUT 1 2 WATER INP UT RE FI LL MAI N POW ER 2 1 1 2 3 3 3 FLAV OR OUT PUT FLAV OR OUT PUT WATER OUT PUT FLAV OR OUT PUT WATER OUT PUT WATER OUT PUT SERVICE (cont.) REFILL SWITCHES FIG. 14 REFILL SWITCHES Location: The refill switches are located on the upper right front of the autofill box.
16 FLA VO R IN PU T 1 2 W A T E R IN P UT R EF ILL M AIN PO W E R 2 1 1 2 3 3 3 FLA V O R O UTP UT FLA VO R O U TP UT W A T ER O U TP UT FLA VO R O U TPU T W A T ER O UTP UT W A T ER O UTP U T SERVICE (cont.) SOLENOIDS FIG. 16 SOLENOIDS Location: The solenoids are located inside the autofill box.
17 FLA VO R IN PU T 1 2 W A T E R IN P UT R EF ILL M AIN PO W E R 2 1 1 2 3 3 3 FLA V O R O UTP UT FLA VO R O U TP UT W A T ER O U TP UT FLA VO R O UTP U T W A T ER O UTP U T W A T ER O UTP U T SERVICE (cont.
18 FLA VO R IN PU T 1 2 W A T E R IN P UT R EF ILL M AIN PO W E R 2 1 1 2 3 3 3 FLA V O R O UTP UT FLA VO R O U TP UT W A T ER O U TP UT FLA VO R O UTP U T W A T ER O UTP U T W A T ER O UTP U T SERVICE (cont.
19 FLA VO R IN PU T 1 2 W A T E R IN P UT R EF ILL M AIN PO W E R 2 1 1 2 3 3 3 FLA V O R O UTP UT FLA VO R O U TP UT W A T ER O U TP UT FLA VO R O UTP U T W A T ER O UTP U T W A T ER O UTP U T SERVICE (cont.
20 SERVICE (cont.) V ACUUM/SUPPL Y PUMP TUBE INST ALLA TION FIG. 24 TUBING ST ART POSITION P1542 ROLLERS PUMP HEAD TUBING KEY ENTRY PORT EXIT PORT FIG. 25 TUBING LOADED ROTOR ROTOR SHAFT P1541 2. Separate the two halves of the pump and carefully remove the tubing from within.
21 V ACUUM SWITCHES FIG. 26 V ACUUM SWITCHES Location: The vacuum switches are located inside autofill box, mounted on the left side of the solenoid mounting bracket just below the needle valves. T est Procedure: 1 . Disconnect the dispenser from the power source.
22 PIPING DIAGRAM (AFPO-2) The only difference between the AFPO-2/3 and AFPO-2/3 SL is the SL models have a water output line and a flavor output line for each product. This allows the water and flavor to be mixed in the hoppers. Refer to the illustration below when connecting the lines.
23 GRN SOL #1 SOL #2 PUMP #1 PUMP #2 10 AMP MAIN ON/OFF SWITCH REFILL ON/OFF SWITCH #1 REFILL ON/OFF SWITCH #2 J4-1 2 3 4 5 6 7 8 9 J4-10 C I R C U I T B O A R D L1 N BLK BLK BLK B L K B L K B L K SOL.
24 41093 040408.
25 GRN SOL #1 SOL #2 PUMP #1 PUMP #2 10 AMP MAIN ON/OFF SWITCH REFILL ON/OFF SWITCH #1 REFILL ON/OFF SWITCH #2 J4-1 2 3 4 5 6 7 8 9 J4-10 C I R C U I T B O A R D L1 L2 BLK BLK BLK B L K B L K B L K SO.
デバイスBunn AFPO-3の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Bunn AFPO-3をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはBunn AFPO-3の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Bunn AFPO-3の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Bunn AFPO-3で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Bunn AFPO-3を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はBunn AFPO-3の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Bunn AFPO-3に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちBunn AFPO-3デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。