ADTRANメーカー612の使用説明書/サービス説明書
ページ先へ移動 of 264
61200624L1- 1B June 2004 T OTAL ACCESS 600 SERIES System Manual T otal Access 600R T otal Access 604 T otal Access 608 T otal Access 612 T otal Access 616 T otal Access 624.
Trademarks Total Access 600 Series System Manual 2 © 2004 ADTRAN, Inc. 61200624L1-1B T rademarks Any brand names and produ ct names included in this manual ar e trademarks, registered trad emarks, or trade names of their respective holders. T otal Access ® is a registered trad emark of ADTRAN, Inc.
Total Access 600 Series System Manual Revision History 61200624L1-1B © 2004 ADTRAN, Inc. 3 Revision History Conventions Document Revision Date Description of Changes A October 2002 Initial Release B May 2004 Updated to include menu changes for firmware release.
Safety Instructions Total A ccess 600 Series System Manual 4 © 2004 ADTRAN, Inc. 61200624L1-1B Safety Instructions When using your telephone equi pment, please follow these basic safety precautions to reduce the risk of fire, electrical shock, or personal injury: 1.
Total Access 600 Series System Manual FCC-Required Information 61200624L1-1B © 2004 ADTRAN, Inc. 5 FCC-Required Information FCC regulations require that the following informat ion be provided in this manual: 1. This equipment complies with Part 68 of FCC rules and requirements adopted by ACT A.
FCC-Required Informat ion Total Access 600 Series Sy stem Manual 6 © 2004 ADTRAN, Inc. 61200624L1-1B Federal Communications Co mmission Radio Frequency Inte rference Statement This equipment has been tested and found to comply with the limits for a Class A digit al device, pursuant to Part 15 of the FCC Rules.
Total Access 600 Series System Manual Affidavit Requirements for Connection to Digita l Services 61200624L1-1B © 2004 ADTRAN, Inc. 7 Affidavit Requirements for C onnection to Digital Services • An .
Affidavit Requir ements for Connection to Digital Services To tal Access 600 Series Sy stem Manual 8 © 2004 ADTRAN, Inc. 61200624L1-1B A FFIDAVIT FOR C ONNECTION OF C US TOMER P REMISES E QUIPMENT TO 1.
Total Access 600 Series System Manual Industry Canada Compliance Information 61200624L1-1B © 2004 ADTRAN, Inc. 9 Industry Canada Compliance Information Before installing this equipment, users should ensure that it is permissible to be connected to the f acilities of the local telecommunications co mpany .
Product Warranty Total Access 600 Series System Manual 10 © 2004 ADTRAN, Inc. 61200624L1-1B Product W arranty ADTRAN will repair and return this p roduct within the warranty period if it does not meet its publis hed specifications or fails whil e in service.
Total Access 600 Series System Manual Customer Se rvice, Product Support In formation, and Training 61200624L1-1B © 2004 ADTRAN, Inc. 11 Post-Sale Support Y our resel ler should serve as the first point of contact for support.
Customer Service, Product Support Informa tion, and Training Total Access 600 Series System Manual 12 © 2004 ADTRAN, Inc. 61200624L1-1B.
Total Access 600 Series System Manual Table of Contents 61200624L1-1B © 2004 ADTRAN, Inc. 13 T able of Contents Section 1 System Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 This section provides an overview of the Total Access 600 Series system.
Table of Contents Total Access 600 Series System Manual 14 © 2004 ADTRAN, Inc. 61200624L1-1B.
61200624L1-1B © 2004 ADTRAN, Inc. 15 SYSTEM DESCRIPTION This section provides an over view of the T otal Access 600 Series system. C ONTENTS System Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Section 1 System Descriptio n Total Access 600 Serie s System Manual 16 © 2004 ADTRAN, Inc. 61200624L1-1B 1. SYSTEM OVERVIEW The T otal Access 600 Series contains Integrated Access Devices (IAD) designed for cost-effective deployment of voice and data services at the cust omer premises.
Total Access 600 Series System Manua l Section 1 System Description 61200624L1-1B © 2004 ADTRAN, Inc. 17 2. FEATURES AND BENEFITS The following list gives T otal Access 600 Series featur es and benefits.
Section 1 System Descriptio n Total Access 600 Serie s System Manual 18 © 2004 ADTRAN, Inc. 61200624L1-1B Frame Relay Support • Copper Mountain CE fragmentation su pport • Annex A, Annex D, and LMI suppor t (T1) • FRF.
Total Access 600 Series System Manua l Section 1 System Description 61200624L1-1B © 2004 ADTRAN, Inc. 19 Performance Monitoring • Reports: Information stored for last 24 hours in 15 minut e increments • Performance sta tistics pe r TR54016, T1.403, RFC14 06 • Alarm reporting per TR54016, T1.
Section 1 System Descriptio n Total Access 600 Serie s System Manual 20 © 2004 ADTRAN, Inc. 61200624L1-1B ADSL • P/N 42 00644L1 Total Access 604 ADSL • P/N 4200644L1#A CB Total Access 604 ADSL wi.
61200624L1-1B © 2004 ADTRAN, Inc. 21 ENGINEERING GUIDELINES This section provides equi pment dimensions, power re quir ements, front panel design, re ar panel design, LEDs, and at-a-glance specifications. C ONTENTS Equipment Dimensions . . . . . . . .
Section 2 Engineering Guideli nes Total Access 600 Series System Manual 22 © 2004 ADTRAN, Inc. 61200624L1-1B Table 10. V.35 Winchester Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Table 11.
Total Access 600 Series System Manual Section 2 Engineering Guidelines 61200624L1-1B © 2004 ADTRAN, Inc. 23 1. EQUIPMENT DIMENSIONS T otal Access 600R, T otal Access 604/608 The T otal Access 600R and T otal Access 604/608systems measure 1 1.25” W , 7.
Section 2 Engineering Guideli nes Total Access 600 Series System Manual 24 © 2004 ADTRAN, Inc. 61200624L1-1B Front Panel LEDs The front panel p rovides five st atus LEDs to mon itor operation and activity . T able 3 provides LED descriptions for T otal Access 600R systems.
Total Access 600 Series System Manual Section 2 Engineering Guidelines 61200624L1-1B © 2004 ADTRAN, Inc. 25 Front Panel LEDs The front panel provides eight status LEDs to m onit or operation and activity . The LED functionality varies based on product and softwa re load (TDM versus A TM).
Section 2 Engineering Guideli nes Total Access 600 Series System Manual 26 © 2004 ADTRAN, Inc. 61200624L1-1B Table 4. To tal Access 6XX ATM Fr ont Panel LE Ds For these LEDs... This col or light... Indicates that... TX/RX Off there is no data traf fic on the LAN.
Total Access 600 Series System Manual Section 2 Engineering Guidelines 61200624L1-1B © 2004 ADTRAN, Inc. 27 T otal Access 612/616/624 The front panels of the T otal Access 612/616/624 sy stems are identical. Figure 3 shows the T otal Access 612 front panel as a representative of all models.
Section 2 Engineering Guideli nes Total Access 600 Series System Manual 28 © 2004 ADTRAN, Inc. 61200624L1-1B 4. REVIEWIN G THE RE AR PANEL DESIGN The T otal Access 600R provides a NTWK connection (vi.
Total Access 600 Series System Manual Section 2 Engineering Guidelines 61200624L1-1B © 2004 ADTRAN, Inc. 29 Figure 5. Total Access 604/608 Rear Panel Figure 6. Total Access 604/608 Rear Panel with Optional Life Line POTS Figure 7. Total Access 604/608 Rear Panel wit h Optional DSX-1 Interface Figure 8.
Section 2 Engineering Guideli nes Total Access 600 Series System Manual 30 © 2004 ADTRAN, Inc. 61200624L1-1B Figure 10. Total Access 612/6 16/624 Rear Panel with Optional DSX-1 Interface VOICE Connec.
Total Access 600 Series System Manual Section 2 Engineering Guidelines 61200624L1-1B © 2004 ADTRAN, Inc. 31 CRAFT Port The CRAFT port (EIA-232) on the rear panel connec ts to a computer or modem an d provides the followin g functions: • Accepts EIA-232 input from a PC or a mode m for controlling the Total Access 600 Series.
Section 2 Engineering Guideli nes Total Access 600 Series System Manual 32 © 2004 ADTRAN, Inc. 61200624L1-1B Note: All other pins are unused. Table 8.
Total Access 600 Series System Manual Section 2 Engineering Guidelines 61200624L1-1B © 2004 ADTRAN, Inc. 33 10/100BaseT Connection The 10/100BASET port (RJ-48C) p rovides a 10/100Bas eT Ethernet LAN connection fo r IP Routing , TFTP , SNMP , and T elnet connections.
Section 2 Engineering Guideli nes Total Access 600 Series System Manual 34 © 2004 ADTRAN, Inc. 61200624L1-1B Life Line Analog Connection The LIFE LINE analog connection provides assured voice for port 1. If the unit loses power or goes into alarm, the network voice service is inhibited and the on-board relay op ens.
Total Access 600 Series System Manual Section 2 Engineering Guidelines 61200624L1-1B © 2004 ADTRAN, Inc. 35 5. AT-A-GLANCE SPECIFICATIONS T able 13 lists the unit specifications. Table 13. Specifications Application Feature Specification T1 Network Interface Physical I nterface RJ-48C Line Rate 1.
Section 2 Engineering Guideli nes Total Access 600 Series System Manual 36 © 2004 ADTRAN, Inc. 61200624L1-1B Analog Ports Number of FXS Ports 4 po rts for T otal Ac cess 604 8 ports for T otal Access.
61200624L1-1B © 2004 ADTRAN, Inc. 35 NETWORK T URNUP PROCEDURE This section provides shipmen t contents list, groundi ng instructions, mounting op tions, and specifics of supplying power to the unit. C ONTENTS Tools Required . . . . . . . . . . . . .
Network Tu rnup Procedu re Total Access 600 Series Sy stem Manual 36 © 2004 ADTRAN, Inc. 61200624L1-1B 1. INTRODUCTION This section discusses T otal Access 600 Series installation.
Total Access 600 Series System Manual Section 3 Network Turnup Procedure 61200624L1-1B © 2004 ADTRAN, Inc. 37 Contents of ADTRAN Shipments Y our ADTRAN shipment includes the following items: • The .
Network Tu rnup Procedu re Total Access 600 Series Sy stem Manual 38 © 2004 ADTRAN, Inc. 61200624L1-1B 5. MOUNTING OPTIONS All units may be wallmounted or installed in a table-top application. In addition, the T otal Access 612/616/624 units are available for 19- or 23-inch rackmount installa tions.
Total Access 600 Series System Manual Section 3 Network Turnup Procedure 61200624L1-1B © 2004 ADTRAN, Inc. 39 Figure 1. Wallmount Orie ntation Figure 2. Wallmounting the Unit Note : The T otal Access 600 Series units come equipped with wall mount brac kets preinstalled.
Network Tu rnup Procedu re Total Access 600 Series Sy stem Manual 40 © 2004 ADTRAN, Inc. 61200624L1-1B Rackmounting the T o tal Access 612/616/624 T ools Needed The T otal Access 612/616/624 mount an.
61200624L1-1B © 2004 ADTRAN, Inc. 41 USER INTERFACE GUIDE This section of ADTRAN’s T otal Access 600 Series System Manual is designed for use by network administrators and others who will configure and provision the sy stem. It contai ns information about navigating the VT100 user inte rface, configur ation informat ion, and menu desc riptions.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 42 © 2004 ADTRAN, Inc. 61200624L1-1B F IGURES Figure 1. Top-Level Terminal Menu Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Figure 2.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 43 1. NAVIGATING THE T ERMINAL MENU T o access the terminal menus and management features of the T otal Access 6XX, connect the unit to a VT100 terminal (or VT100 terminal emulator) via the CRAFT interface on the rear pane l.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 44 © 2004 ADTRAN, Inc. 61200624L1-1B Figure 2. Alternate Menu View Window Pane Navigatio n Use the following chart to assis t you in moving between and within the two window panes.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 45 Additional T e rminal Menu Window Features • Mod e – displays the network interface mode .
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 46 © 2004 ADTRAN, Inc. 61200624L1-1B Session Manage ment Keystrokes Configuration Keystrokes Move to th e bottom of a screen Z Ascend one menu level Backspace Jump to terminal mode CTRL+T Jump to NA T menu CTRL+N T o do this.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 47 Getting Help The bottom line of the term inal menu window contains context- sensitive help information.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 48 © 2004 ADTRAN, Inc. 61200624L1-1B Security Levels T o edit main menu system items, you must have a p assword and the appropriate security level. T able 1 describes the security levels.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 49 S YSTEM I NFO The S YSTEM I NFO menu provides basic information about th e unit as well as data fields for editing information. Figure 3 displays th e submenus th at are available when you select this menu item.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 50 © 2004 ADTRAN, Inc. 61200624L1-1B S YSTEM I NF O > P ART N UMB ER (Read only) Displays the ADTRAN-sp ecific part number for the unit. S YSTEM I NF O > C ONTROLLER S ERIAL N UMBER (Read only) Displays the ADTRAN-spec ific part number for the chassis hardware.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 51 S YSTEM C ONFIG Set up the unit’ s operational configuration from the S YSTEM C ONFIG menu. Figure 4 shows the items included in this menu. Figure 4.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 52 © 2004 ADTRAN, Inc. 61200624L1-1B S YSTEM C ONFIG > M ANAGEMENT > CRAFT P ORT > I DLE T IME This option defines the amount of time in minutes user may stay connected without any activity on the CRAFT port before the user is automatically logged out of the system.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 53 S YSTEM C ONFIG > M ANAGEMENT > T ELNET A CC ESS > A CCES S Sets A CCESS to O N or O FF to allow or block telnet access to the unit. The factory default value for this parameter is O N .
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 54 © 2004 ADTRAN, Inc. 61200624L1-1B S YSTEM C ONFIG > M ANAGEMENT > T ELNET A CC ESS > A CTIV E S ESSIONS Provides a list of all T elnet sessions currently active on the system.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 55 S YSTEM C ONFIG > M ANAGEMENT > T ELNET A CC ESS > IP A CCESS L IST Set up the list of allowed T elnet connections by specif ying the IP address of the sy stems used to control the unit.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 56 © 2004 ADTRAN, Inc. 61200624L1-1B S YSTEM C ONFIG > M ANAGEMENT > SNMP M ANAG EMENT > T RAPS Sets up the trap manager name and IP from this menu.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 57 S YSTEM C ONFIG > M ANAGEMENT > FDL M ANAG EMENT > M ODE This enables the FDL (only in ESF mo de) to be used for management.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 58 © 2004 ADTRAN, Inc. 61200624L1-1B S YSTEM C ONFIG > S YSLOG > S YSLOG IP IP address of the syslog daemon to which log message should be sent. The values must be dotted decimal notation.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 59 SYSLOG using T erminal Mode Another option for configuring sy slog is using the terminal mode com mand log dump <logname> . The logname must be all CAPS must ma tch the listings below .
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 60 © 2004 ADTRAN, Inc. 61200624L1-1B S YSTEM C ONFIG > S YSLOG > ARP L EVEL Minimum required level for sending ARP log mess ages. Address Resolution Protocol log messages provide status information for all ARP requests sent and received by the unit.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 61 S YSTEM C ONFIG > S YSLOG > TOLLBRG L EVEL Minimum required level for sending lo g messages about communication with the T ollbridge V oice Gateway .
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 62 © 2004 ADTRAN, Inc. 61200624L1-1B S YSTEM C ONFIG > S YSLOG > POTS L EVEL Minimum required level for sending lo g m essages about POTS line cards and services.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 63 S YSTEM C ONFIG > S YSLOG > VOA TM L EVEL Minimum required level for sending V oice-over-A TM log messages.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 64 © 2004 ADTRAN, Inc. 61200624L1-1B S YSTEM C ONFIG > N ETWORK T IME > A DJUST FOR D AYLIGHT S AVING Since some areas of.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 65 S YSTEM U TILITY > U PGRADE F IRMWARE Select the firmware upgrade method and perform upgrade from this menu.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 66 © 2004 ADTRAN, Inc. 61200624L1-1B T o support these transfers, ADTRAN delivers a TFTP program with the unit called TFTP Server . Y ou can configure any PC run ning Microsoft W indows with this software, and store a configuration file.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 67 S YSTEM U TILITY > S YS TEM U TILIZATION V iew the CPU utilization stats from this menu.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 68 © 2004 ADTRAN, Inc. 61200624L1-1B S YSTEM U TILITY > S YS TEM U TILIZATION > P ERFOR MANCE > C LEAR S TATS This activator will clear all the sy stem utilization performance stats.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 69 S YSTEM U TILITY > T RACEROUTE > T RACE T AR GET Specifies the IP address of the remo te system to trace the routes to.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 70 © 2004 ADTRAN, Inc. 61200624L1-1B Options: repeat <repeat count> Number of pings to send (default 5) size (datagram si.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 71 I NTERFACES Use the I NTERFACES menu to view and config ure paramete rs for the various system interfaces ( T1 , SHDSL , SDSL , ADSL , Ethernet ( ETH ), V.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 72 © 2004 ADTRAN, Inc. 61200624L1-1B I NTERFACES (T1) > C ONFIG > L INE C ODE This sets the line code for the T1 in terface. The setting must match the line code of the circuit to which the interface is connected.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 73 I NTERFACES (T1) > S TATUS > P ERFORMANCE > C URRENT AND T OTALS > SES SES (Severely Errored Second) - For ESF mode, an SES is a second with 320 or more PCVs, or one or more OOF defects, or a detected AIS defect.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 74 © 2004 ADTRAN, Inc. 61200624L1-1B I NTERFACES (T1) > S TATUS > A LA RMS > C URRENT A LARMS Displays the current alarms on the T1 inte rface. An asterisk in a field indicates that an alarm is active.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 75 I NTERFACES (N ETWORK SHDSL) V iew the network SHDSL interface status and config ure SHDSL parameters from this menu. These me nus are only applicable to SHDSL T otal Access 600 Series systems.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 76 © 2004 ADTRAN, Inc. 61200624L1-1B I NTERFACES (SHDSL) > S TATUS > G. HS E VENT Internal ADTRAN use only . I NTERFACES (SHDSL) > S TATUS > G. HS S TATE Internal ADTRAN use only .
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 77 I NTERFACES (SDSL) > S TATUS Displays the SDSL interface status information. I NTERFACES (SDSL) > S TATUS > SDSL R ATE Displays the current ne gotiated SDSL data rate.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 78 © 2004 ADTRAN, Inc. 61200624L1-1B I NTERFACES (DSX) V iew the integrated DSX interface status an d configure T1 parameters from this menu. I NTERFACES (DSX) > C ONFIG Configure the various DSX parameters an d enable/disable loopbacks from this menu.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 79 I NTERFACES (DSX) > S TATUS > P ERFORM ANCE > C URRE NT AND T OTALS > I NTERVAL Identifies the interval ( C URRENT or T OTAL ) for the listed performance statistics.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 80 © 2004 ADTRAN, Inc. 61200624L1-1B I NTERFACES (DSX) > S TATUS > P ERFORM ANCE > C LEAR A LL D ATA Clears all statistics collected in the C URRENT AND T OTALS and the E XTENDED 24 hour statistics tables.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 81 I NTERFACES (DSX) > T EST > R EM LB Sends a loopback command across the network to a remote unit over the FDL, which causes the remote unit initiate a local L INE or P AYLOAD loopback (whichever is specified).
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 82 © 2004 ADTRAN, Inc. 61200624L1-1B I NTERFACES (V35) V iew the V .35 interface status and config ure the V .35 paramete rs from this menu. I NTERFACES (V35) > C ON FIG Configure the DTE leads from this menu.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 83 I NTERFACES (FXS) > C ONFIG > P ORT Indicates the port of the FXS module. I NTERFACES (FXS) > C ONFIG > M ODE Choices are given below .
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 84 © 2004 ADTRAN, Inc. 61200624L1-1B I NTERFACES (FXS) > C ONFIG > S VC M ODE Indicates whether the module is I N S ERVICE or O UT OF S VC . This does not indicate whether the port has been mapped.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 85 I NTERFACES (FXS) > C ONFIG > T ANDEM > D IAL T ON E Used to enable or disabl e the on-board dial ton e genera tion. Dial T one is supplied for 5 sec; then it drops.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 86 © 2004 ADTRAN, Inc. 61200624L1-1B I NTERFACES (FXS) > S TATUS > RA S IG This parameter displays the status of the Receive A signal bit. The high /low status is indicated by a 0 or 1.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 87 I NTERFACES (FXO) > C ONFIG Configure the FXO mo de, line impe dance, and T andem para meters from this menu. I NTERFACES (FXO) > C ONFIG > P ORT Indicates the port of the FXO module.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 88 © 2004 ADTRAN, Inc. 61200624L1-1B I NTERFACES (FXO) > S TATUS > P ORT Displays the port number . I NTERFACES (FXO) > S TATUS > T A S IG This parameter displays the status of the Transmit A signal bit.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 89 L2 P ROTOCOL (TDM F IRMWARE ) Use the L2 protocol menu to select the L2 pro tocol, config ure the protocol specific parameters and view the status as shown in Figure 7.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 90 © 2004 ADTRAN, Inc. 61200624L1-1B L2 P ROTOCOL (TDM F IRMWARE ) – T1 I NTERFACE Configure the L2 Protocol parameters and view the status of the Network T1 interface using items from this menu.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 91 L2 P ROTOCOL (TDM F IRMWARE ) – T1 I NTERFACE > PPP Configure the L2 P ROTOCOL parameters and view the status of the T1 interface using PPP pro tocol from this menu.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 92 © 2004 ADTRAN, Inc. 61200624L1-1B L2 P ROTOCOL (TDM–T1–PPP) > C ONFIG > PPP > M AX T IMER ( SEC ) This value is the numbers of secon ds to wait between unans wered co nfiguration-requests.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 93 L2 P ROTOCOL (TDM–T1–PPP) > S TATUS > R X P KTS Number of packets receiv ed on the T1 i nterface. L2 P ROTOCOL (TDM–T1–PPP) > S TATUS > T X B YT ES Number of bytes transmitt ed on the T1 interface.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 94 © 2004 ADTRAN, Inc. 61200624L1-1B L2 P ROTOCOL (TDM–T1–FRE) > C ON FIG > M AINTENAN CE P ROTO COL The Frame Relay maintenance protocol is used on th e W AN port.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 95 L2 P ROTOCOL (TDM–T1–FRE) > C ON FIG > DLCI M APPI NG I NTERF ACE Shows the user the physical and logical port asso ciated with each DLCI.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 96 © 2004 ADTRAN, Inc. 61200624L1-1B L2 P ROTOCOL (TDM–T1–FRE) > S TATUS > P ORT > C URRENT U TIL (b/s) Current utilization of the T1 interface ba ndwidth presented in bits per second.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 97 L2 P ROTOCOL (TDM–T1–FRE) > S TATUS > PVC( S ) > S TATE The state of the virtual.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 98 © 2004 ADTRAN, Inc. 61200624L1-1B L2 P ROTOCOL (TDM F IRMWARE ) – T1 I NTERFACE > HDLC P ROTOCOL V iew the status of the T1 interface with the L2 P ROTOCOL set to HD LC .
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 99 L2 P ROTOCOL (TDM F IRMWARE ) – T1 I NTERFACE > A UTO P ROTOCOL V iew the status of the T1 interface with the L2 P ROTOCOL set to A UTO (using Auto-config feature).
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 100 © 2004 ADTRAN, Inc. 61200624L1-1B L2 P ROTOCOL (A TM F IRMWARE ) Use the L2 P ROTOCOL menu to select the L2 P ROTOCO L , configure the protocol specific parameters, and view the status as shown in Figure 7.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 101 L2 P ROTOCOL (A TM F IRMWARE ) – N ETWORK (NET) I NTERFACE Configure the L2 P ROTOCOL parameters for these menus are identic al regardless of network interface.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 102 © 2004 ADTRAN, Inc. 61200624L1-1B L2 P ROTOCOL (A TM–NET–A TM) > C ONFIG > A TM C ONFIG > D ATA S CRAMBLING D ATA S CRAMBLING can be E NABLED or D ISABLED for cell traffic.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 103 L2 P ROTOCOL (A TM–NET–A TM) > C ONFIG > P VC C ONFIG > VCI This is the A TM V i rtual Channel Identifier that serves as an address for the virtual channel cell transmissions between two devices.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 104 © 2004 ADTRAN, Inc. 61200624L1-1B T X M ETHOD Specifies the method the T otal Acces s 600 Series uses to obtain PPP authentication from the peer . There are four possible selections: N ONE The connection will not allow the PPP peer to authenticate it.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 105 L2 P ROTOCOL (A TM–NET–A TM) > C ONFIG > P VC C ONFIG > S ETUP (V35) Use these menus to configure the V3 5 parameters for this logical connection from the T1 interface to the V .
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 106 © 2004 ADTRAN, Inc. 61200624L1-1B C ONNECTION (V35) > S ETUP > S ETUP Use these menus to configure the Protocol mapp ing, DE map, and FECN map for th e V .35 PVC connections .
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 107 L2 P ROTOCOL (A TM–NET–A TM) > C ONFIG > P VC C ONFIG > S ETUP (V OICE ) Use th.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 108 © 2004 ADTRAN, Inc. 61200624L1-1B L2 P ROTOCOL (A TM–NET–A TM) > S TA TUS Displays all available A TM statistics (both overall and PVC-specific). L2 P ROTOCO L (A TM–NET–A TM) > S TA TUS > A TM S TATUS Displays overall A TM link performance statistic s.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 109 L2 P ROTOCOL (A TM–NET–A TM) > S TA TUS > PVC S TATUS V iew the A TM PVC statistics from this menu. L2 P ROTOCOL (A TM–NET–A TM) > S TA TUS > PVC S TATUS > N UM Displays the index number in the PVC Status menu.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 110 © 2004 ADTRAN, Inc. 61200624L1-1B L2 P ROTOCOL (T1 A TM–T1–A TM) > S TA TUS > P VC S TATUS > P ROTO COL S TATUS Use these menus to view the AAL2 S TATS , P OTS S TATS , and to C LEAR S TATS for the PVC Protocol.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 111 L2 P ROTOCOL (A TM F IRMWARE ) – N ETWORK I NTERFACE > C U M TN FRE Configure the L2 P ROTOCOL parameters and view the status o f the network interface using Copper Mountain Frame Relay protocol from this menu.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 112 © 2004 ADTRAN, Inc. 61200624L1-1B L2 P ROTOCOL (A TM–NET–C U MTN) > C ONFIG > N UM Displays the index number in the DLCI config table.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 113 L2 P ROTOCOL (A TM–NET–C U MTN) > S TATUS > DLC I S TATE This is a read-only field that displays the live DLCI state.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 114 © 2004 ADTRAN, Inc. 61200624L1-1B L2 P ROTOCOL (A TM – V35)> S TATUS > P ORT Displays statistics for all the PVCs configured on this port.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 115 L2 P ROTOCOL (A TM F IRMWARE ) – DSX I NTERFACE Configure the L2 P ROTOCOL parameters and view the status of the integrated DSX interface using items from this menu.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 116 © 2004 ADTRAN, Inc. 61200624L1-1B L2 P ROTOCOL (A LL F IRMWARE ) – ETH I NTERFACE > 802.3 P ROTOCOL Configure the L2 PROTOCOL parameters and view the status of the Ethernet interface from this menu.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 117 L2 P ROTOCOL (ALL–ETH–802.3) > S TATUS > R X E RRORS Number of packets receiv ed in error and dropped. L2 P ROTOCOL (ALL–ETH–802.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 118 © 2004 ADTRAN, Inc. 61200624L1-1B B RIDGE > C ONFIG > I NTERFACES (N ETWORK ) Configure the network interface brid ging parameters from this menu. B RIDGE > C ONFIG > I NTERFACES (NET) > S UB -I NT ERFACE The network sub-interfa ce is PPP [0.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 119 B RIDGE > S TATUS > B RI DGE T ABLE > L OCATION Location indicates if it is LAN or W AN.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 120 © 2004 ADTRAN, Inc. 61200624L1-1B R OUTER > C ONFIG > I NTERFACES (ETH) > S UB -I NTERFACE This is a read-only field which displays the physical and logical por t of the interface using the following nomenclature: [A.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 121 TX AND RX ( DEF ) RIP advertisements are periodically tran smitted and are listened to on this port. TX O NLY RIP advertisements are periodically transm itted but are not listene d to on this port.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 122 © 2004 ADTRAN, Inc. 61200624L1-1B R OUTER > C ONFIG > I NTERFACES (N ETWOR K ) Configure the layer 3 options for the network interface from this menu.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 123 IP N ETMASK This is the network mask used for this interface. This field is not visible when A DDRESS M ODE is set to DHCP C LIENT . F AR -E ND IP A DDRESS This is the address of the NEXT hop router on this interface.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 124 © 2004 ADTRAN, Inc. 61200624L1-1B P UBLIC A DDRESS M ODE Choose NAPT A DDR (default) or S PECIFIED to choose which address to use for this translation. Choosing S PECIFIED allows the user to define a dif ferent public IP address to use for this translation.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 125 P UBLIC P ORT This menu ap pears when th e P UBLIC P ORT M ODE is set to S PECIFIED . Use this option to specify the public port nu mber to translate.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 126 © 2004 ADTRAN, Inc. 61200624L1-1B T RANSLAT E B ODY If set to Y ES , the application pay load in the packet is scanned for occurrences of the private/public IP address i n binary or ASCII form.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 127 I N C OUNT Number of inbo und packet s using this translation. O UT C OUNT Number of outbou nd packet s using this translation. NAPT A DDRESS (Read only) Displays the NAP T address for the router .
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 128 © 2004 ADTRAN, Inc. 61200624L1-1B R OUTER > C ONFIG > R OUTES Configures the default gateway an d static routes from this menu.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 129 R OUTER > C ONFIG > DHCP S ERVER > DHCP S ERVER Use this menu to enable the DHCP server ( O N or O FF ).
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 130 © 2004 ADTRAN, Inc. 61200624L1-1B N ETWORK M ASK Defines the network mask associated with the ne twork address for the configured address pool (for example, 255.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 131 R OUTER > C ONFIG > DHCP S ERVER > E XC LUSION R ANGES Defines any IP address (or range of addresses ) that should not be used the T otal Access 600 Series DHCP server when making IP assignme nts to hosts on the network.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 132 © 2004 ADTRAN, Inc. 61200624L1-1B R OUTER > S TATU S V iew the IP R OUTES , IP S TATS , ARP C ACHE , DHCP S ERVER , and DHCP C LIENT statistics from this me nu. R OUTER > S TATU S > IP R OUTES This lists the contents of the unit’ s IP route table.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 133 R OUTER > S TATU S > IP R OUTES > F LAGS Important tags associated with this route entry R OUTER > S TATU S > IP R OUTES > H OPS Number of routers that must go through to get to destinati on.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 134 © 2004 ADTRAN, Inc. 61200624L1-1B IP D ATAGRAMS R ECEIVED The total number of input data grams received from interfaces, including those re ceived in error .
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 135 R OUTELESS D ISCARDS The number of IP datagrams discard ed because no route could be found to transmit them to their destination.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 136 © 2004 ADTRAN, Inc. 61200624L1-1B R OUTER > S TATU S > IP S TATS > ICMP ICMP MESSAGES RECEIVED The total number of ICMP messag es the unit received. Note that this counter includes all those counted by ICMP S PECIFIC E RRORS .
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 137 ICMP A DDRESS M ASK R EPLY M SGS R CVD The number of ICMP Address Mask Reply messages received. ICMP M ESSAGES S ENT The total number of ICMP messages this unit attempted to send.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 138 © 2004 ADTRAN, Inc. 61200624L1-1B R OUTER > S TATU S > IP S TATS > UDP V iew the UDP statistics from this menu. R OUTER > S TATU S > IP S TATS > UDP T ABLE V iew the UDP table statistics from this menu.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 139 R OUTER > S TATU S > IP S TATS > TCP V iew the TCP statistics from this menu. R ETRANSMISSION T IMEOUT A LGORITHM The algorithm used to de termine the timeout value used for retransmitting unackn owledged octets.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 140 © 2004 ADTRAN, Inc. 61200624L1-1B R OUTER > S TATU S > IP S TATS > TCP C ONNS V iew the TCP Conns Statistics from this menu. This table shows the dif ferent states of each TCP connection.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 141 R OUTER > S TATU S > ARP C ACHE > IP A DDRESS IP address used for resolving MAC address. R OUTER > S TATU S > ARP C ACHE > MAC A DDRESS Ethernet address resolved (0=no resolution).
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 142 © 2004 ADTRAN, Inc. 61200624L1-1B S ECURITY > F IL TERS > F ILTER D EFINES The unit can filter packets based on certain parameters within the pack et.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 143 S ECURITY > F IL TERS > F ILTER D EFINES > P ATTERN F ILTER D EFINES The pattern filter is applied to bridge packets only . Th at is any p acket which is forwarded by th e bridge functionality of the unit.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 144 © 2004 ADTRAN, Inc. 61200624L1-1B N AME Identifies the filter entry . Default is no entry in name field. F ILTER T YPE Specifies a N ORMAL or D EBUG filter . When a N ORMAL filer is applied to an interface, traffic is blocked or forwarded according to the filter .
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 145 S ECURITY > F IL TERS > I NTERFACES The unit can bl ock packets in and out o f an interface by us e of the filters.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 146 © 2004 ADTRAN, Inc. 61200624L1-1B S ECURITY > F IL TERS > I NTERFACES > S ET - UP Enable packet blocking or fo rwarding and appl y pre-defined filter exc eptions from this menu.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 147 N EXT O PER The next operation to use to combine with the next filter in the list (default is E ND ). END the last filter to combination. AND logically AND this filter with the next filter in the list.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 148 © 2004 ADTRAN, Inc. 61200624L1-1B S ECURITY > R AD IUS S ERVER The parameters for the R ADIUS S ERVER are configured in this menu.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 149 S ECURITY > R AD IUS S ERVER > R ETRY C OUNT (1-10) This is the number of times the unit should send a request packet tho the R ADIUS S ERV ER without a response before giving up.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 150 © 2004 ADTRAN, Inc. 61200624L1-1B DS0 M APS > A CTIV E M AP Activates one of the two dedicated maps ( M AP 1 or M AP 2 ), or the D UAL T1 M AP (only available in units with the optional DSX-1 interface).
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 151 DS0 M APS > E DIT /V IEW M AP 1 > RBS V oice applications require si gnaling information to identi fy the state of the channel.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 152 © 2004 ADTRAN, Inc. 61200624L1-1B 4. APPENDICES (T1 TDM APPLICATIONS) Appendix A. Configuri ng the Unit for Routing Initial Setup It is best to configure T otal Acces s 6XX TDM applic a tions by following the order of the top-level menus.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 153 2. Configuring the Layer 2 Protocol For more details on the co nfiguration parameters disc u.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 154 © 2004 ADTRAN, Inc. 61200624L1-1B 7 Set DLCI to the DLCI number . This D LCI s hould match what is programmed in the network Frame Relay switch.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 155 3. Setting the Router Options For more details on the co nfiguration parameters disc ussed i.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 156 © 2004 ADTRAN, Inc. 61200624L1-1B 4. Mapping the DS0s For more details on the co nfiguration parameters disc ussed in this .
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 157 DS0 Mapping Instructio ns Step Action 1 From the main menu, select DS0 M APS . 2 V erify that the A CTIVE M AP is set to either M AP 1 or M AP 2 .
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 158 © 2004 ADTRAN, Inc. 61200624L1-1B Appendix B. Configuring the Unit for Bridging Initial Setup It is best to configure T otal Acces s 6XX TDM applic a tions by following the order of the top-level menus.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 159 2. Configuring the Layer 2 Protocol For more details on the co nfiguration parameters disc u.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 160 © 2004 ADTRAN, Inc. 61200624L1-1B 7 Set DLCI to the DLCI number . This D LCI s hould match what is programmed in the network Frame Relay switch.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 161 3. V erifying the Bridge Options For more details on the co nfiguration parameters disc ussed in this section, re fer to the following pages: Bridge menus beginnin g on page 1 17 4.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 162 © 2004 ADTRAN, Inc. 61200624L1-1B 2 V erify that th e A CTIVE M AP is set to either M AP 1 or M AP 2 . This is the map that is actively running on the unit. The unit has the ability to store two maps.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 163 Appendix C. Configur ing the Unit for V oice Applications Initial Setup It is best to configure T otal Acces s 6XX TDM applic a tions by following the order of the top-level menus.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 164 © 2004 ADTRAN, Inc. 61200624L1-1B FXS Interface Set up Instructio ns Step Action 1 From the main menu, select I NTERFACES . 2 Highlight the C ONFIG menu for the FXS inte rface and press <E NTER > .
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 165 2. Mapping the DS0s For more details on the co nfiguration parameters disc ussed in this sec.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 166 © 2004 ADTRAN, Inc. 61200624L1-1B Appendix D. Configuring the Unit for DSX-1 Applications The T otal Access 600 Series systems are available with an integrated DSX-1 interface for both voice and data applications.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 167 2. Mapping the DS0s For more details on the co nfiguration parameters disc ussed in this sec.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 168 © 2004 ADTRAN, Inc. 61200624L1-1B DS0 Mapping Instructio ns Step Action 1 From the main menu, select DS0 M APS . 2 V erify that th e A CTIVE M AP is set to either M AP 1 or M AP 2 .
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 169 5. APPENDICES (T1 A TM APPLICATIONS) Appendix A. V oice Gateway Quick Start Procedure (V oice T urn Up) A typical V oA TM application (see Figure 7) uses a T otal Access 6X X connected to an A TM ne twork.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 170 © 2004 ADTRAN, Inc. 61200624L1-1B The following example provides step by step instru ctions for configuring the T otal Access 6XX T1 A TM system ( I NTERFACES and L2 P ROTOCOL ) for a standard voice application.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 171 FXS Interface Set up Instructio ns Step Action 1 From the main menu, select I NTERFACES . 2 Highlight th e C ONFIG menu for the FXS interface and press <E NTER > .
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 172 © 2004 ADTRAN, Inc. 61200624L1-1B 2. Configuring the Layer 2 Protocol For more details on the co nfiguration parameters dis.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 173 8 Select S ETUP , and from the S ETUP menu, enter the Ga teway type under C ALL C ONTROL and enter the VPI and VCI value s for communicating with that Gateway .
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 174 © 2004 ADTRAN, Inc. 61200624L1-1B Appendix B. RFC1483 Quick Start (IP Routing) The T otal Access 6XX allows for complete integrat ion of voice and data delivery from one compact platform (see Figure 10).
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 175 T1 Interface Setup Instructions Step Action 1 From the main menu, select I NTERFACES . 2 Highlight the C ONFIG menu for the T1 inter face and press <E NTER > .
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 176 © 2004 ADTRAN, Inc. 61200624L1-1B . 2. Configuring th e Layer 2 Protocol For more details on the co nfiguration parameters .
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 177 3. Setting the Router Options For more details on the co nfiguration parameters disc ussed i.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 178 © 2004 ADTRAN, Inc. 61200624L1-1B 3 Select I NTERFACES and press <E NTER > . Use the right arrow key to h ighlight the S ETUP field for the T1 interf ace and pres s <E NTER > .
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 179 Appendix C. RFC1483 Quick St art (IP Routing with NA T) T o illustrate the use of NA T , consider the example from Appendix B. RFC1483 Quick Start (IP Routing) on page 174.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 180 © 2004 ADTRAN, Inc. 61200624L1-1B Appendix D. RFC 1483 Quick Start (Bridging) Initial Setup It is best to configure T otal Acces s 6XX A TM applic a tions by following the order of the top-level menus.
Total Access 600 Series System Manual Section 4 User Interface Guide 61200624L1-1B © 2004 ADTRAN, Inc. 181 . 2. Configuring th e Layer 2 Protocol For more details on the co nfiguration parameters dis.
Section 4 Use r Interface G uide Total Access 600 Series Sy stem Manual 182 © 2004 ADTRAN, Inc. 61200624L1-1B 3. V erifying the Bridge Options For more details on the co nfiguration parameters disc ussed in this section, re fer to the following pages: Bridge menus beginnin g on page 1 17 9 Set mode to R OUTE IP .
61200624L1-1B © 2004 ADTRAN, Inc. 183 DETAIL LEVEL PROCEDURES DLP-1 C onnecting a VT100 Terminal or PC to the CRAFT Port . . . . . . . . . . . . . . . . . . . . . . . . . . . 185 DLP-2 Logging in to the System . . . . . . . . . . . . . . . . . . . . .
Section 5 Detail Level Procedures Total Access 600 Series System Manual 184 © 2004 ADTRAN, Inc. 61200624L1-1B.
61200624L1-1B © 2004 ADTRAN, Inc. 185 DLP-1 Connecting a VT100 T erminal or PC to the CRAFT Port Introduction T otal Access 6XX shelf management an d provisioning are facilitated by a series of intuitive menus that are accessible on a computer screen.
Section 5 DLP-1 Total Access 600 Series System Manual 186 © 2004 ADTRAN, Inc. 61200624L1-1B 1. Connecting a VT10 0 terminal to T o tal Access 6XX : 2. Connect a PC emulating a VT -100 terminal to T otal Access 6XX. Most personal computers (PCs) or laptops can ru n communications software that emulates a VT100 terminal.
61200624L1-1B © 2004 ADTRAN, Inc. 187 DLP-2 Logging in to the System Introduction Once connected to the T otal Access 6XX, you must logi n to the system to gain access to the management and provisioning functions. This DLP assumes you ar e connected to the T otal Access 6XX and provides specific steps for logg ing into the system.
Section 5 DLP-2 Total Access 600 Series System Manual 188 © 2004 ADTRAN, Inc. 61200624L1-1B 1. After connecting to the system, press any key to display the Login screen shown here. The blinking cursor at the Login field indicate s that a password must be entered.
61200624L1-1B © 2004 ADTRAN, Inc. 189 DLP-3 Setting IP Parameters Introduction If the T otal Access 6XX is connected to an IP networ k for T elnet, TFTP , or SNMP management, there are several IP parameters which must be set for the unit to communicate with the ne twork.
Section 5 DLP-3 Total Access 600 Series System Manual 190 © 2004 ADTRAN, Inc. 61200624L1-1B 1. Connect the T otal Access 6XX un it to your VT100 system (details found in DLP-1, Connecting a VT100 T erminal or PC to the CRAFT Port ). 2. Log in to the system.
61200624L1-1B © 2004 ADTRAN, Inc. 191 DLP-4 V erifying Communica tions Over an IP LAN Introduction When the Ethe rnet port is conn ecte d to a local area network (LAN), test steps must be performed on the T otal Access 6XX to ensure that the unit is communi cating properly over the network.
Section 5 DLP-4 Total Access 600 Series System Manual 192 © 2004 ADTRAN, Inc. 61200624L1-1B 1. V erify the T otal Access 6XX IP address. If you do not already have the IP Address for th e T otal Acce.
Total Access 60 0 Series Syste m Manual Section 5 DLP-4 61200624L1-1B © 2004 ADTRAN, Inc. 193 From the same computer used in the previous step, T elnet to th e T otal Access 6XX and verify that the T elnet session is properly opened (se e DLP-5, Connecting to the Unit Using T elnet ).
Section 5 DLP-4 Total Access 600 Series System Manual 194 © 2004 ADTRAN, Inc. 61200624L1-1B.
61200624L1-1B © 2004 ADTRAN, Inc. 195 DLP-5 Connecting to the Unit Using T elnet Introduction If the T otal Access 6XX is part of a management cluste r connected to the local network, you may use a PC connected to the network to T elnet into the unit.
Section 5 DLP-5 Total Access 600 Series System Manual 196 © 2004 ADTRAN, Inc. 61200624L1-1B 1. Connect the computer to the T otal Acces s 6XX CRAFT interface (details in D LP-1, Connecting a VT100 T erminal or PC to the CRAFT Port ). 2. Log in to the unit.
Total Access 60 0 Series Syste m Manual Section 5 DLP-5 61200624L1-1B © 2004 ADTRAN, Inc. 197 1 1. Press <CTRL+ L> to log off the T otal Access 6XX terminal menu system. 12. From a remote com puter sy stem conne cted to the LAN, T elnet to the T ota l Access 6XX.
Section 5 DLP-5 Total Access 600 Series System Manual 198 © 2004 ADTRAN, Inc. 61200624L1-1B 14. Enter the password assigne d in step 6. After entering the correct password, the T otal A ccess 6XX main menu is displayed (see belo w): 15.
61200624L1-1B © 2004 ADTRAN, Inc. 199 DLP-6 Adding/Removing Users and Changing Password Security Levels Introduction All menu items in the T otal Access 6XX are protect ed by passwords of varying security levels.
Section 5 DLP-6 Total Access 600 Series System Manual 200 © 2004 ADTRAN, Inc. 61200624L1-1B 1. Connect to the T otal Access 6XX using either the 10/100BASET or CRAFT inte rface.
Total Access 60 0 Series Syste m Manual Section 5 DLP-6 61200624L1-1B © 2004 ADTRAN, Inc. 201 8. Determine the password le vel for the co rrespondin g label. The T otal A ccess 6XX cont ains seven diff erent password levels. The following chart gi ves a brief description of ea ch level.
Section 5 DLP-6 Total Access 600 Series System Manual 202 © 2004 ADTRAN, Inc. 61200624L1-1B.
61200624L1-1B © 2004 ADTRAN, Inc. 203 DLP-7 Updating the Firmware using TFTP Introduction The T otal Access 6XX supports firmware updates using TFTP or XMODEM. (Use the 10/100BASET Ethernet port and TFTP from a network server , or use XMODEM and the rear CRAFT interfaces.
Section 5 DLP-7 Total Access 600 Series System Manual 204 © 2004 ADTRAN, Inc. 61200624L1-1B 1. Connect to the T otal Access 6XX using the 10/100BASET interfac e. If you are not already connected to the unit’ s ETHERNET port using T elnet client software, use the procedure in DLP-5, Connecting to the Unit Usi ng T elnet , to connect to the unit.
Total Access 60 0 Series Syste m Manual Section 5 DLP-7 61200624L1-1B © 2004 ADTRAN, Inc. 205 9. Select S TART T R ANSFER to start the update. Enter Y to confirm th e upgrade . Prior to the start of the upgrade, the transfer status will displ ay I DLE .
Section 5 DLP-7 Total Access 600 Series System Manual 206 © 2004 ADTRAN, Inc. 61200624L1-1B.
61200624L1-1B © 2004 ADTRAN, Inc. 207 DLP-8 Updating the Fi rmware using XMODEM Introduction The T otal Access 6XX supports firmware updates using TFTP or XMODEM. (Use the 10/100BASET Ethernet port and TFTP from a network server , or use XMODEM and the rear CRAFT interface.
Section 5 DLP-8 Total Access 600 Series System Manual 208 © 2004 ADTRAN, Inc. 61200624L1-1B Updating Firmware via the Console Menus 1. Connect to the T otal Access 6XX using CRAFT (RJ-48) interface. Selecting a hi gher baud rate connection makes the file transfer pr ocess faster .
61200624L1-1B © 2004 ADTRAN, Inc. 209 DLP-9 Saving the Current Configuration Using TFTP Introduction The T otal Access 6XX supports c onfiguration transfers from the unit (via the 10/100BASET Ethernet port) to a TFTP server located on the ne twork.
Section 5 DLP-9 Total Access 600 Series System Manual 210 © 2004 ADTRAN, Inc. 61200624L1-1B 1. Connect to the T otal Access 6XX using the 10/100BASET interfac e.
61200624L1-1B © 2004 ADTRAN, Inc. 211 DLP-10 Loading a Con f iguration Using TFTP Introduction The T otal Access 6XX supports config uration uploads from a unit (via the 10/100BA SET Ethernet port) to a TFTP server located on the network.
Section 5 DLP-10 Total Access 600 Series System Manual 212 © 2004 ADTRAN, Inc. 61200624L1-1B 1. Connect to the T otal Access 6XX using the 10/100BASET interface.
61200624L1-1B © 2004 ADTRAN, Inc. 213 DLP-1 1 Saving and T ransferring a Current Configuration Using XMODEM Introduction The T otal Access 6XX supports configur ation transfers from the unit via the CRAFT interface using a VT100 terminal or terminal emulator (with XMODE M).
Section 5 DLP-11 Total Access 600 Series System Manual 214 © 2004 ADTRAN, Inc. 61200624L1-1B 1. Connect to the T otal Access 6XX using the CRAFT (RJ-48) port on the back of the T otal Access 6X X.
61200624L1-1B © 2004 ADTRAN, Inc. 215 DLP-12 Loading a Config uration Using XMODEM Introduction The T otal Access 6XX supports configuration uploads from a unit via the CRAFT interface using a VT100 terminal or terminal emulator (with XMODEM ).
Section 5 DLP-12 Total Access 600 Series System Manual 216 © 2004 ADTRAN, Inc. 61200624L1-1B 1. Connect to the T otal Access 6XX using the CRAFT (RJ-48) interface.
61200624L1-1B © 2004 ADTRAN, Inc. 217 DLP-13 Saving and Loading T ext Configuration using T erminal Command Line Introduction The T otal Access 6XX has the ability to download a text file which contains the config uration of the entire unit. This configuration may then be altered in a text editor and uploaded to any T otal Access 6XX .
Section 5 DLP-13 Total Access 600 Series System Manual 218 © 2004 ADTRAN, Inc. 61200624L1-1B Saving the T otal Access 6XX configuration 1. Establish a connection to the T otal Access 6 XX with th e VT100 te rminal software using the CRAFT port or T elnet via the 10/100BASET Ethe rnet interface.
Total Access 600 Series System Manual Section 5 DLP-13 61200624L1-1B © 2004 ADTRAN, Inc. 219 5. Enable "capt ure" or "loggin g" in the te rminal so ftware, s aving it to a file on your computer . 6. Press the SP ACE BAR to continue.
Section 5 DLP-13 Total Access 600 Series System Manual 220 © 2004 ADTRAN, Inc. 61200624L1-1B.
61200624L1-1B © 2004 ADTRAN, Inc. 221 DLP-14 A.03 to A.04 Firmware Upgrade Introduction The T otal Access line of Integrated Access Devic es includes both the A T M and TDM versions of the T otal Access 6XX. Until now , the T ota l Access TDM units have been runn ing firmware version A.
Section 5 DLP-14 Total Access 600 Series System Manual 222 © 2004 ADTRAN, Inc. 61200624L1-1B T ools and Materials Required • VT100 compatible terminal or comput er with terminal emulati on software.
61200624L1-1B © 2004 ADTRAN, Inc. 223 DLP-15 Using the ADTRAN Utility Syslog Introduction The T otal Access 6XX Syslog Utility records various message types at se ttable threshold levels to an external Syslog server (software supplied with the T otal Access 6XX system ADTRAN Utilities).
Section 5 DLP-15 Total Access 600 Series System Manual 224 © 2004 ADTRAN, Inc. 61200624L1-1B 1. Log in to the system with maximum rights (see DL P-2, Logging in to the System ). Once you have logged into the T otal Access 6XX, go to S YSTEM C ONFIG /S YSLOG .
Total Access 600 Series System Manual Section 5 DLP-15 61200624L1-1B © 2004 ADTRAN, Inc. 225 . •T h e M ONITOR feature allows all Syslog messages to be prefiltered by S YSTEM N AME , S OURCE , S LOT , and P ORT before displaying these messages to the user and logging the message to the pre-designated monitor log file.
Section 5 DLP-15 Total Access 600 Series System Manual 226 © 2004 ADTRAN, Inc. 61200624L1-1B • Under the L OG F ILES menu option, the user may erase log files, define Red events, set priorities, and clear Red events. The E RASE L OG F ILES option erases the spec ified text log file.
64203376L1-1A © 2004 ADTRAN, Inc. 227 DLP-16 Executing T erminal Mode Commands Introduction Once connected to the unit via either a VT100 termi nal or PC configured as a VT100 terminal or via T elnet.
Section 5 DLP-16 Total Access 850 System Manual 228 © 2004 ADTRAN, Inc. 64203376L1-1A 1. Connect to the unit usin g either the 10/100BA SET or CRAFT interfaces.
Total Access 850 System Manual Section 5 DLP-16 64203376L1-1A © 2004 ADTRAN, Inc. 229 j. Perform a traceroute or extended traceroute. Syntax is: traceroute host name/address [hops xx] [timeout xx] [r.
Section 5 DLP-16 Total Access 850 System Manual 230 © 2004 ADTRAN, Inc. 64203376L1-1A.
61200624L1-1B © 2004 ADTRAN, Inc. 231 DLP-17 Configuring Dual T1 Maps Introduction T otal Access 6XX T1 TDM systems with the optional DSX-1 interface have a D UAL T1 M AP feature that allows two network T1 connections for the termination of data an d voice applications.
Section 5 DLP-17 Total Access 600 Series System Manual 232 © 2004 ADTRAN, Inc. 61200624L1-1B 1. Connect the T otal Access 6XX un it to your VT100 system (details found in DLP-1, Connecting a VT100 T erminal or PC to the CRAFT Port ). 2. Log in to the system with maximu m rights (details ar e in DLP-2, Logging in to the System ).
Total Access 600 Series System Manual Section 5 DLP-17 61200624L1-1B © 2004 ADTRAN, Inc. 233 5. Edit the Primar y T1 Map by pressing <Enter> on E DIT /V IEW T1 M AP [+] .The following screen appears. Figure 2. Primary T1 Map The T1 Map can b e mapped to the internal r outer or other available interfaces.
Section 5 DLP-17 Total Access 600 Series System Manual 234 © 2004 ADTRAN, Inc. 61200624L1-1B 6. Edit the Se condary T1 Map (DSX Ma p) by pressing <Enter> on E DIT /V IEW DSX M AP [+] . The following screen appears. Figure 3. DSX M ap 7. Left arrow back to DS0 M APS and log off by pressing <CTRL+L> .
61200624L1-1B © 2004 ADTRAN, Inc. 235 DLP-18 Unit Installation Us ing the Auto-Config Feature Introduction A UTO -C ONFIG allows the service provider to gain initial acces s to a newly installed IAD while in its factory default state.
Section 5 DLP-18 Total Access 600 Series System Manual 236 © 2004 ADTRAN, Inc. 61200624L1-1B 1. V eri fy the unit is at factory de fault. 2. Connect the network inte rface cable to the NTWK port on the rear of th e unit.
Total Access 600 Series System Manual Section 5 DLP-18 61200624L1-1B © 2004 ADTRAN, Inc. 237 5. Once the L2 protocol detection is c omplete, the service pr ovider can t elnet into the unit using th e IP address assign ed by the router/DH CP server . 6.
Section 5 DLP-18 Total Access 600 Series System Manual 238 © 2004 ADTRAN, Inc. 61200624L1-1B.
61200624L1-1B © 2004 ADTRAN, Inc. 239 DLP-19 TDM to A TM Upgrade Introduction The Echo Canceller Module p rovides G.165/G.168 echo cancellation for voice ov er A TM applications and is available with Adaptive Dif ferential Pulse Code Modulation (ADPCM).
Section 5 DLP-19 Total Access 600 Series System Manual 240 © 2004 ADTRAN, Inc. 61200624L1-1B The upgrade package may be purchased from ADTR AN. This package include s the EC/ADPCM (P/N 1200613L1) and the ADTRAN installation and test . If this package is ordered, the customer must send the T otal Access TDM 612/616/624 unit back to ADTR AN.
Total Access 600 Series System Manual Section 5 DLP-19 61200624L1-1B © 2004 ADTRAN, Inc. 241 9. Factory default the T otal Access 612/616/624 by one of the following methods: • Select S YSTEM U TILITY > T ERMINAL M ODE . At the > pro mpt, type factory_reset .
Section 5 DLP-19 Total Access 600 Series System Manual 242 © 2004 ADTRAN, Inc. 61200624L1-1B.
61200624L1-1B © 2004 ADTRAN, Inc. 243 ADTRAN UTILITIES This section provides instructio ns for configuring and using the ADTRAN Utilities so ftware programs including T elnet, VT10 0, Syslog, and TFT P . ADTRAN delivers several PC software utilities with the T otal Access 600 Series.
Section 6 ADTRAN Utilities Total Access 600 Series System Manual 244 © 2004 ADTRAN, Inc. 61200624L1-1B 1. T ELNET UTILITY Access the T elnet program remotely through the Ethern et port.
Total Access 600 Series System Manual Section 6 ADTRAN Utilities 61200624L1-1B © 2004 ADTRAN, Inc. 245 Session Menu Click on S ESSION to open the T elnet session. Connect Opens dialog box for setting H OST N AME and P ORT parameters for a T elnet session.
Section 6 ADTRAN Utilities Total Access 600 Series System Manual 246 © 2004 ADTRAN, Inc. 61200624L1-1B Disconnect T erminates the T elnet session. T o re-establish the session, select C ONNECT from S ESSION M ENU or press E NTER three times. This action restores the previous connection.
Total Access 600 Series System Manual Section 6 ADTRAN Utilities 61200624L1-1B © 2004 ADTRAN, Inc. 247 Help Menu Provides online help for using the ADTRAN Utilities. Contents Opens the online help. IP Status Displays the local port address an d the status of the connection.
Section 6 ADTRAN Utilities Total Access 600 Series System Manual 248 © 2004 ADTRAN, Inc. 61200624L1-1B Session Menu Opens VT100 terminal emulation session. Connect Opens a specified serial port for a VT100 session. Disconnect Closes a specified serial port at the end of a VT100 session.
Total Access 600 Series System Manual Section 6 ADTRAN Utilities 61200624L1-1B © 2004 ADTRAN, Inc. 249 Capture Menu Identical to the T elnet C APTURE M ENU (see Captur e Menu on page 246). Help Menu Provides online help and inform ation about the version number .
Section 6 ADTRAN Utilities Total Access 600 Series System Manual 250 © 2004 ADTRAN, Inc. 61200624L1-1B Figure 4. TFTP Server Interface Only one configuration transfer session (upload or download) may be active at a time.
Total Access 600 Series System Manual Section 6 ADTRAN Utilities 61200624L1-1B © 2004 ADTRAN, Inc. 251 Help Provides online help a nd version information. Contents Opens online help. About Displays version and owner information. 4. STATUS FIELD This field displays general informatio n about port and transfer status.
Section 6 ADTRAN Utilities Total Access 600 Series System Manual 252 © 2004 ADTRAN, Inc. 61200624L1-1B.
61200624L1-1B © 2004 ADTRAN, Inc. 253 MIBS This section is divided into two parts: (1) SNMP in formation for TDM units and (2) SNMP informa tion for A TM units. Each section details th e Management Information Ba ses (MIBs) supported, MIB Co mpilation Order , T raps Supported, and MIB V ariables supported.
Section 7 MIBs Total Access 600 Series System Manual 254 © 2004 ADTRAN, Inc. 61200624L1-1B 1. MIBS SUPPORTED BY TDM UNITS All TDM MIBs ar e SNMPv2. Standard RFC MIBs: RFC1573.mi2 IANAifT ype-MIB RFC1907.mi2 SNMPv2-MIB RFC201 1.mi2 IP-MIB RFC2096.mi2 IP-FORW A RD-MIB RFC21 15.
Total Access 600 Series System Manual Section 7 MIBs 61200624L1-1B © 2004 ADTRAN, Inc. 255 2. MIB COMPILATION ORDER FOR TDM UNITS 3. T RAPS SUPPORTED BY TDM UNIT S IANAifT ype-MIB PerfHist-TC-MIB SNM.
Section 7 MIBs Total Access 600 Series System Manual 256 © 2004 ADTRAN, Inc. 61200624L1-1B 4. MIB V ARIABLES SUPP ORTED BY TDM UNITS SNMPv2 states the su pported MIB variables by the follo wing method: The unit will have a MIB called T A 6XX.mi2 that w ill describe the SNMP variab les supported.
Total Access 600 Series System Manual Section 7 MIBs 61200624L1-1B © 2004 ADTRAN, Inc. 257 tcp: tcpRtoAlgorithm RO tcpRtoMin RO tcpRtoMax RO tcpMaxConns RO tcpActiveOpens RO tcpPassiveOpens RO tcpAtt.
Section 7 MIBs Total Access 600 Series System Manual 258 © 2004 ADTRAN, Inc. 61200624L1-1B egp: egpInMsgs RO egpInErrs RO egpOutM sgs RO egpOutErro rs RO egpNeighS tate RO egpNeigh Addr RO egpNeighA .
Total Access 600 Series System Manual Section 7 MIBs 61200624L1-1B © 2004 ADTRAN, Inc. 259 dsx1CurrentEntry dsx1Curren tIndex RO dsx1CurrentESs RO dsx1CurrentSESs RO dsx1CurrentSEFs RO dsx1CurrentUAS.
Section 7 MIBs Total Access 600 Series System Manual 260 © 2004 ADTRAN, Inc. 61200624L1-1B dsx1Frac Index RO dsx1Frac Number RO dsx1FractIfIndex RO snmp: snmpInPkts RO snmpOutPkts RO snmpInBadV ersio.
Total Access 600 Series System Manual Section 7 MIBs 61200624L1-1B © 2004 ADTRAN, Inc. 261 atmInterfac eEntry atmInterfa ceMaxVpcs RO atmInterfa ceMaxVccs RO atmInterfa ceConfVpcs RO atmInterfa ceCon.
Section 7 MIBs Total Access 600 Series System Manual 262 © 2004 ADTRAN, Inc. 61200624L1-1B atmVclT ransmitT raf ficDescrIndex RO atmVccAal T ype RO atmVccAal5CpcsT ransmitSduSize RO atmVccAal5CpcsRec.
デバイスADTRAN 612の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
ADTRAN 612をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはADTRAN 612の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。ADTRAN 612の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。ADTRAN 612で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
ADTRAN 612を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はADTRAN 612の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、ADTRAN 612に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちADTRAN 612デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。