61221002L2-5B 1 ADTRAN ® AHDSL2 Asynchronous H2TU-C Line Card for Alcatel Litespan ® Channel Bank Assemblies Using Narrowband Pairs Installation and Maintenance Practice Section 61221002L2-5B Issue 2, August 2003 CLEI Code: SLL5R3DG_ _ CONTENTS 1. General .
2 61221002L2-5B Table 1 lists and defines the H2TU-C Front Panel LED indicators. Each ADTRAN Litespan H2TU-C line card provides a 1.552 kbps data transport over one unconditioned CSA copper pair. These CSA loops can range up to 12 kft of 24-AWG twisted pair wire.
61221002L2-5B 3 2. APPLICATIONS The ADTRAN HDSL2 system provides a cost-effective alternative for deploying T1 service over metallic cable pairs. In contrast with traditional T1 service equipment, ADTRAN HDSL2 can be successfully deployed over one unconditioned, nonloaded, bridged-tapped copper pair CSA loop (see Deployment Guidelines , Section 4).
4 61221002L2-5B CAUTION Prior to installing or removing the Litespan H2TU-C, observe the following warning: If the Litespan H2TU-C is removed from a line card slot, wait at least 15 seconds before reinsertion. If connected to the MTI craft interface terminal, wait until the message “AID:MJ,UEQ.
61221002L2-5B 5 Provisioning Commands Upon initial insertion of the Litespan H2TU-C into the Litespan system, configuration options are downloaded automatically to the line card and take precedence over the ADTRAN default provisioning options.
6 61221002L2-5B 1 L T s d n a m m o C t f a r c e t i L s r e t e m a r a P C - U T 2 H s n o i t p O C - U T 2 H s g n i t t e S e l b a l i a v A g n i d n o p s e r r o C s g n i t t e S t f a r c .
61221002L2-5B 7 Testing Commands The H2TU-C testing commands are used to initiate and terminate loopbacks and disconnect for testing purposes. Table 8 lists and defines the TL1/Litecraft testing commands. NOTE Before entering loopbacks, the user needs to remove the card from service.
8 61221002L2-5B Figure 4. Deployment Guidelines Table 9 lists the ADTRAN Litespan H2TU-C and H2TU-R factors needed to calculate channel bank power using Worksheet PW-1. The Table 9 power factors are derived from the power parameters listed in Table 10 .
61221002L2-5B 9 Loop loss per kft for other wire is summarized in Table 11 . Cable Gauge 26 26 24 24 22 22 19 19 Cable Type PIC Pulp PIC Pulp PIC Pulp PIC Pulp Temperature ( ° F) 68 ° 90 ° 120 ° 3.902 4.051 4.253 4.030 4.179 4.381 2.863 2.957 3.083 3.
10 61221002L2-5B Table 13. Troubleshooting Guide Condition At power up, all front panel indicators are OFF The STAT LED remains RED. The STAT LED is OFF, but the HLOS LED remains RED . The STAT LED is OFF, but the RLOS LED remains RED. Solution 1. Verify that the channel bank or ONU BPS power LEDs are on.
61221002L2-5B 11 Table 14. ADTRAN H2TU-C Specifications Loop Interface Modulation Type ............................................... 16 TC PAM Mode .................................................................. Full duplex, partially overlapped echo canceling Number of Pairs .
12 61221002L2-5B This page is intentionally blank..
61221002L2-5B A-1 HDSL MAINTENANCE MODES This appendix describes operation of the HDSL2 system with regard to detection of in-band and ESF facility data link loopback codes. Upon deactivation of a loopback, the HDSL2 system will synchronize automatically.
A-2 61221002L2-5B Table A-1. In-Band Addressable Loopback Codes n o i t c n u Fe d o Ce s n o p s e R 3 n i 1 1 0 0 1. g n i h t y r e v e n w o d p o o L 6 n i 1 1 0 0 0 0 0 1 e r o f e b d e m r a e b t s u m ; k r o w t e n e h t d r a w o t R - U T 2 H e h t t a k c a b p o o L .
61221002L2-5B A-3 n o i t c n u Fe d o Ce s n o p s e R n w o d p o o L 3 , 1 3 9 3 9 1 0 0 1 1 1 0 0 1 0 0 1 1 1 0 0 k c a b p o o l n i y l t n e r r u c s t i n u l l a , r e m o t s u c r o k r o w t e n e h t m o r f t n e s n e h W a e k i l e v a h e b o t r e d r o n I .
A-4 61221002L2-5B This page is intentionally blank..
61221002L2-5B B-1 Appendix B TL1 H2TU-C T utorial GENERAL This appendix is intended to highlight the necessary menus/commands needed to provision the ADTRAN H2TU-C card. A more detailed explanation of shelf specific items may be found in the Alcatel TL1 Reference Practice, OSP-363-205-502.
B-2 61221002L2-5B MAINTENANCE MENU AND ASSOCIATED SUB-MENUS From the Main Menu, enter “2” to display the Maintenance Menu as shown below. Maintenance Menu 1. ADSL Maintenance Menu 2. ATM Maintenance Menu 3. EC1 Maintenance Menu 4. Equipment Maintenance Menu 5.
61221002L2-5B B-3 HDSL MAINTENANCE MENU From the Maintenance Menu, enter “6” to display the HDSL Maintenance Menu as shown below. HDSL Maintenance Menu 1. ALW-MSG-HDSL 2. INH-MSG-HDSL 3. RMV-HDSL 4. RST-HDSL 5. RTRV-ALM-HDSL ← ← ← ← ← Retrieve existing HDSL alarms for the H2TU-C 6.
B-4 61221002L2-5B T1 MAINTENANCE MENU From the Maintenance Menu, enter “20” to display the T1 Maintenance Menu as shown below. T1 Maintenance Menu 1. ALW-MSG-T1 2. ALW-SW-T1 3. CONN-JACK-T1 4. DISC-JACK-T1 5. INIT-REG-T1 ← ← ← ← ← Clears the T1 PM data for the H2TU-C 6.
61221002L2-5B B-5 PROVISIONING MENU From the Main Menu, enter “3” to display the Provisioning Menu as shown below. Provisioning Menu 1. ADSL Provisioning Menu 2. Cross-Connection Menu ← ← ← ← ← Item of interest for the H2TU-C 3. EC1 Provisioning Menu 4.
B-6 61221002L2-5B CROSS-CONNECTION MENU From the Provisioning Menu, enter “2” to display the Cross-Connection Menu as shown below. Cross-Connection Menu 1. DLT-CRS-STS1 2. DLT-CRS-T0 3. DLT-CRS-T1 ← ← ← ← ← Delete an existing cross-connect 4.
61221002L2-5B B-7 ENT-CRS-T1 Command Input Format The choice to enter cross-connects may be accomplished either by selecting “12” from the Cross-Connection Menu or by entering the command directly as shown in the example below where a cross-connect is initiated between slot 1 and slot 21.
B-8 61221002L2-5B HDSL PROVISIONING MENU From the Provisioning Menu, enter “6” to display the HDSL Provisioning Menu as shown below. HDSL Provisioning Menu 1. DLT-HDSL 2. ED-HDSL ← ← ← ← ← Edit HDSL provisioning parameters for the H2TU-C 3.
61221002L2-5B B-9 <ED-HDSL LPBKACTR[]={0000000000000000 | 0000000000000001}; or <ED-HDSL::RT-1-21:::: LPBKACTR ={0000000000000000 | 0000000000000001}; <ED-HDSL LPBKDEACTCDE[]={000000000000000.
B-10 61221002L2-5B Grade of Service tables allow the user to set performance monitoring threshold levels for various alarms/event conditions. There are 15 GOS tables available for each type of service (in our case T1 and HDSL).
61221002L2-5B B-11 <ED-T1 FMT[]={ESF | SF | UNFR | AUTO}; or <ED-T1::RT-1-21::::FMT={ESF | SF | UNFR | AUTO}; <ED-T1 LINECDE[]= {AMI | B8ZS}; or <ED-T1::RT-1-21::::LINECDE={AMI | B8ZS}; TESTING MENU From the Main Menu, enter “4” to display the Testing Menu as shown below.
B-12 61221002L2-5B NOTE Prior to entering any loopback command, the line card must be removed from service. Remove card from service = RMV-HDSL; H2TU-C Network Loopback Loop up command = OPR-LPBK-HDSL.
61221002L2-5B C-1 This appendix describes the testing functionality available for the ADTRAN H2TU-C card via the MTAU unit. For a complete description of the MTAU unit refer to Alcatel document Common Equipment Unit Descriptions , OSP 363-405-250.
C-2 61221002L2-5B Figure C-2 . MON Mode HDSL2 T ransceiver AHDSL2 T est LIU Tip A-3 HDSL2 Loop Ring1 A-4 T AE, RAE EQPT jacks on the MT A U TBE, RBE Alcatel Network Equip MON Mode Used to test tow ard.
デバイスADTRAN AHDSL2の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
ADTRAN AHDSL2をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはADTRAN AHDSL2の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。ADTRAN AHDSL2の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。ADTRAN AHDSL2で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
ADTRAN AHDSL2を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はADTRAN AHDSL2の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、ADTRAN AHDSL2に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちADTRAN AHDSL2デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。