7F06-02 FDDI Smar tSWITCH ™ Interf ace Module User’ s Guide 9031672-01.
Notice i NO TICE Cabletron Systems r eserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made.
Notice ii FCC NO TICE This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference r eceived, including interference that may cause undesired operation.
Notice iii VCCI NO TICE This equipment is in the 1st Class Category (information equipment to be used in commercial and/or industrial ar eas) and conforms to the standards set by the V oluntary Control Council for Interference by Information T echnology Equipment (VCCI) aimed at preventing radio interfer ence in commercial and/or industrial areas.
v CONTENTS CHAPTER 1 INTRODUCTION 1.1 USING THIS MANUAL ......................................................................... 1-1 1.2 THE 7F06-02 MODULE ........................................................................... 1-2 1.2.1 Cable T ype and FPIMs .
vi Contents 5.7 PHYSICAL ................................................................................................5-2 5.7.1 Dimensions .....................................................................................5-2 5.7.2 W eight ......
1-1 CHAPTER 1 INTRODUCTION W elcome to Cabletron Systems 7F06-02 FDDI SmartSwitch Interface Module User ’ s Guide . This guide is a simple refer ence for installing and using the 7F06-02 Module. Before installing this module, you should carefully r ead through this manual to gain a full understanding of its capabilities.
1-2 INTRODUCTION 1.2 THE 7F06-02 MODULE The 7F06-02 Module provides two Fiber Optic ports via fr ont panel FPIM modules. 1.2.1 Cable T ype and FPIMs The 7F06-02 module has two front panel connectors that interface to the 7X00 Smart Switch Module through the chassis backplane.
INTRODUCTION 1-3 Figure 1-1. 7F06-02 Module 1.2.2 7C03 MMA C Smar tSwitch, the 7C04 W orkgr oup SmartSwitch and the 7C04-R W orkgroup SmartSwitch The 7F06-02 Module is designed to be installed in the 7C03 MMAC SmartSwitch, the 7C04 W orkgroup SmartSwitch or the 7C04-R W orkgroup SmartSwitch.
1-4 INTRODUCTION T oken Ring to be used with the 7F06-02 Module. These modules provide the capability to shar e data without the use of external bridges or routers. The 7C03 MMAC SmartSwitch is a unique module that can be installed in an MMAC Series chassis.
INTRODUCTION 1-5 1.4 RELA TED MANU ALS The manuals listed below should be used to supplement the procedur es and other technical data provided in this manual.
2-1 CHAPTER 2 NETWORK REQ UIREMENTS Before installing Cabletr on Systems 7F06-02 Module, review the network requir ements outlined in this chapter . All requir ements included in this chapter should be met to ensure satisfactory performance of the 7F06-02 Module.
2-2 NETWORK REQ UIREMENTS Transmitter power parameters are listed in Table 2-2. The link distance is up to 2 kilometers on the multimode fiber- optic cable as specified by ANSI MMF-PMD. T able 2-2. T ransmitter P ower P arameters Parameter T ypical V alue W orst Case W orst Case Budget T ypical Budget 50/125 µ m fiber -13.
NETWORK REQ UIREMENTS 2-3 2.1.2 FPIM-02 and FPIM-04 The FPIM-02 has an RJ-45 connector supporting an Unshielded T wisted Pair (UTP) connection. The FPIM-04 has an RJ-45 connector supporting a Shielded T wisted Pair (STP) connection. The pinouts for both are listed in T able 2-3.
2-4 NETWORK REQ UIREMENTS 2.1.3 FPIM-05 and FPIM-07 The FPIM-05 and FPIM-07 provide a Single-mode fiber connection. The FPIM-05 uses a MIC style connector and the FPIM-07 uses an SC type connector . The specifications for both devices ar e listed in T able 2-4.
3-1 CHAPTER 3 INST ALLA TION/REMO V AL This chapter contains instructions for unpacking and installing the 7F06-2 Module in the: • 7C03 MMAC SmartSwitch • 7C04 W orkgroup SmartSwitch • 7C04-R W orkgroup SmartSwitch. Also included in the chapter are instr uctions the front panel FPIMs.
3-2 INST ALLA TION/REMO V AL Figure 3-1. Installing an FPIM 3.3 INST ALLING/REMO VING THE 7F06-02 MODULE The following procedur e detail the installing and removal pr ocedure for the 7F06-02 module.
INST ALLA TION/REMO V AL 3-3 Notes: The left most slot in the 7C03 MMAC SmartSwitch is reserved for the 7X00 SmartSwitch Module. Before installing the 7F06-02 module, attach the wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package.
3-4 INST ALLA TION/REMO V AL Note: Before removing the 7F06-02 module, attach the wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package. 1. Use a slotted screwdriver to loosen the two scr ews that secure the module to the chassis.
INST ALLA TION/REMO V AL 3-5 3.3.3 Installing in the 7C04 or 7C04-R W orkgroup SmartSwitch The 7F06-02 Module is installed in the 7C04 or 7C04-R W orkgroup SmartSwitch using the following steps and referring to the appropriate figur e. Notes: The top slot in the 7C04 Workgroup SmartSwitch is reserved for the 7X00 SmartSwitch Module.
3-6 INST ALLA TION/REMO V AL Figure 3-4. Installing the 7F06-02 Module in the 7C04 W orkgroup SmartSwitch Figure 3-5. Installing the 7F06-02 Module in the 7C04-R W orkgroup SmartSwitch SN 1 2 3 4 P S .
INST ALLA TION/REMO V AL 3-7 3.3.4 Removing fr om the 7C04 or 7C04-R W orkgr oup SmartSwitch The 7F06-02 Module, inserted in the 7C04 or the 7C04-R W orkgroup SmartSwitch, can be r emoved whenever necessary . Follow the steps below and refer to the appr opriate figure to remove the module.
3-8 INST ALLA TION/REMO V AL Figure 3-7. Removing the 7F06-02 Module fr om the 7C04-R W orkgroup SmartSwitch FANS SN 4 3 2 1 Ejector T abs Screws.
4-1 CHAPTER 4 TROUBLESHOO TING The 7F06-02 Module uses LANVIEW , Cabletron Systems built-in visual diagnostic and status monitoring system. W ith LANVIEW LEDs the status of each transmit and receive port on the 7F06-02 Module can be determined, at a glance.
4-2 TROUBLESHOO TING T able 4-1 indicates the state of the receive port. T able 4-2 indicates the state of the transmit port. T able 4-1. Port Receive LEDs LED Color State Y ellow (Flashing) Data activity (flashing to steady on indicates rate) Off No activity , port can be disabled or enabled T able 4-2.
TROUBLESHOO TING 4-3 T able 4-3 indicates the state of the A/B Link LEDs. T able 4-3. Link LEDs A p S B State Green N/A N/A Green Ports Enabled & Active Green Green Off Green THRU A, MAC on Primar.
5-1 CHAPTER 5 TECHNICAL SPECIFICA TIONS This chapter includes the technical specifications for Cabletron Systems 7F06-02 module. Cabletron Systems r eserves the right to change these specifications at any time without notice. 5.1 ST AND ARDS IEEE 802.
5-2 TECHNICAL SPECIFICA TIONS 5.5 SAFETY It is the responsibility of the person who sells the system to which the module will be a part to ensure that the total system meets allowed limits of conducted and radiated emissions. This equipment meets the safety requir ements of: • UL 1950 • CSA C22.
デバイスCabletron Systems 7F06-02の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Cabletron Systems 7F06-02をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCabletron Systems 7F06-02の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Cabletron Systems 7F06-02の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Cabletron Systems 7F06-02で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Cabletron Systems 7F06-02を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCabletron Systems 7F06-02の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Cabletron Systems 7F06-02に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCabletron Systems 7F06-02デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。