Title Page 7F06-02 FDDI Smar tSwitch ™ Interf ace Module User’ s Guide 903 9031672-02.
.
7F06-02 FDDI SmartSwitch Interface Module User’ s Guide i NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes ha ve been made.
Notice ii 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide DOC NOTICE This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Notice 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide iii CABLETRON SOFTWARE PROGRAM LICENSE 1. LICENSE . You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this License Agreement.
Notice iv 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide DECLARATION OF CONFORMITY Application of Council Directiv e(s): 89/336/EEC 73/23/EEC Manufacturer’ s Name: Cabletron Systems, Inc. Manufacturer’ s Address: 35 Industrial Way PO Box 5005 Rochester, NH 03867 European Representativ e Name: Mr.
7F06-02 FDDI SmartSwitch Interface Module User’ s Guide v CONTENTS CHAPTER 1 INTRODUCTION 1.1 Using This Manual ....................................................................... 1-1 1.2 The 7F06-02 Module ......................................
Contents vi 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide CHAPTER 5 T ECHNICAL SPECIFICATIONS 5.1 Standards ..................................................................................... 5-1 5.2 EMI .................................
7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 1-1 CHAPTER 1 INTR ODUCTION W elcome to Cabletron Systems 7F06-02 FDDI SmartSwitch Interface Module User Guide .
Chapter 1: Introduction 1-2 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 1.2.1 Cable T ype and FPIMs The 7F06-02 module has two front panel connectors that interface to the 7X00 SmartSwitch Module through the chassis backplane. The front panel connections are standard Cabletron FPIMs.
Chapter 1: Introduction 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 1-3 1.2.2 7C03 MMA C Smar tSwitch, the 7C04 W orkgr oup SmartSwitch and the 7C04-R W orkgroup SmartSwitch The 7F06-02 Module is designed to be installed in the 7C03 MMA C SmartSwitch, the 7C04 W orkgroup SmartSwitch or the 7C04-R W orkgroup SmartSwitch.
Chapter 1: Introduction 1-4 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 1.3.3 Connectivity The 7F06-02 Module has one backplane connection and two sets of A/B front panel FPIM connections. The backplane connection pro vides po wer to the 7F06-02 Module and a channel for communication with the 7X00 SmartSwitch Control Module.
Chapter 1: Introduction 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 1-5 1.5 GETTING HELP If you need additional support related to this de vice, or if you hav e an y questions, comments,.
Chapter 1: Introduction 1-6 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide.
7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 2-1 CHAPTER 2 NETW ORK REQUIREMENTS Before installing Cabletron Systems 7F06-02 Module, re view the network requirements outlined in this chapter . All requirements included in this chapter should be met to ensure satisfactory performance of the 7F06-02 Module.
Chapter 2: Network Requirements 2-2 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide The link distance is up to 2 kilometers on the multimode fiber optic cable as specified by ANSI MMF-PMD. 2.1.2 FPIM-02 and FPIM-04 The FPIM-02 has an RJ-45 connector supporting an Unshielded T wisted Pair (UTP) connection.
Chapter 2: Network Requirements 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 2-3 2.1.3 FPIM-05 and FPIM-07 The FPIM-05 and FPIM-07 provide a single-mode fiber connection. The FPIM-05 uses a MIC style connector and the FPIM-07 uses an SC type connector .
Chapter 2: Network Requirements 2-4 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide.
7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 3-1 CHAPTER 3 INSTALLATION/REMO V AL This chapter contains instructions for unpacking and installing the 7F06-2 Module in the: • 7C03 MMA C .
Chapter 3: Installation/Remov al 3-2 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 3.2 INSTALLING FPIMS The 7F06-02 module is shipped without FPIMs. T o install an FPIM, follo w the procedure belo w: 1. Remove the module if it is installed in the 7C03 MMAC SmartSwitch chassis by reversing the procedure in Section 3.
Chapter 3: Installation/Remov al 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 3-3 3.3 INSTALLING/REMOVING THE 7F06-02 MODULE The follo wing procedure details the installation and remov al procedure for the 7F06-02 module.
Chapter 3: Installation/Remo v al 3-4 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 3.3.2 Removing fr om the 7C03 Smar tSwitch The 7F06-02 Module inserted in the 7C03 MMA C SmartSwitch can be remov ed upon proper remo v al of po wer . Follow the steps belo w and refer to Figure 3-3 to remov e the module.
Chapter 3: Installation/Remo v al 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 3-5 3.3.3 Installing in the 7C04 or 7C04-R W orkgroup SmartSwitch The 7F06-02 Module is installed in the 7C04 or 7C04-R W orkgroup SmartSwitch using the follo wing steps and referring to Figures 3-4 and 3-5.
Chapter 3: Installation/Remo v al 3-6 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide Figure 3-4 Installing the 7F06-02 Module in the 7C04 W orkgroup SmartSwitch Figure 3-5 Installing the 7F.
Chapter 3: Installation/Remo v al 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 3-7 3.3.4 Removing the 7F06-02 fr om the 7C04 or 7C04-R W orkgr oup SmartSwitch The 7F06-02 Module, inserted in the 7C04 or the 7C04-R W orkgroup SmartSwitch, can be removed whene v er necessary .
Chapter 3: Installation/Remo v al 3-8 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide Figure 3-7 Removing the 7F06-02 Module fr om the 7C04-R W orkgroup SmartSwitch FANS SN 4 3 2 1 Ejector T.
7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 4-1 CHAPTER 4 T R OUBLESHOOTING 4.1 DIAGNOSTIC AND MONITORING SYSTEM The 7F06-02 Module uses LANVIEW , Cabletron Systems’ b uilt-in visual diagnostic and status monitoring system.
Chapter 4: T roubleshooting 4-2 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 4.2 P OR T RECEIVE LEDS T able 4-1 indicates the state of the receive port. 4.3 P OR T T RANSMIT LEDS T able 4-2 indicates the state of the transmit port. 4.4 A/B LINK LEDS T able 4-3 indicates the state of the A/B Link LEDs.
Chapter 4: T roubleshooting 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 4-3 Green Off Green Green THR U B, MA C on Secondary , Primary Bypasses Board Green Y ellow Green Green THR U B, M.
Chapter 4: T roubleshooting 4-4 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide.
7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 5-1 CHAPTER 5 T EC HNICAL SPECIFICATIONS This chapter includes the technical specifications for 7F06-02 module. Cabletron Systems reserves the right to change these specifications at an y time without notice.
Chapter 5: T echnical Specifications 5-2 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 5.5 SAFETY It is the responsibility of the person who sells the system to which the module will be a part to ensure that the total system meets allo wed limits of conducted and radiated emissions.
デバイスCabletron Systems FDDIの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Cabletron Systems FDDIをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCabletron Systems FDDIの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Cabletron Systems FDDIの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Cabletron Systems FDDIで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Cabletron Systems FDDIを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCabletron Systems FDDIの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Cabletron Systems FDDIに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCabletron Systems FDDIデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。