61181300L1-5C Section 61181300L1-5C, Issue 3 1 Section 61181300L1-5C Issue 3, October 2000 CLEI Code # M3O1CD0C_ _ T otal Access TM QFO-C Installation and Maintenance 1. GENERAL This practice is an installation and maintenance guide for the ADTRAN Total Access QFO-C, P/N 1181300L1, illustrated in Figure 1 .
2 Section 61181300L1-5C, Issue 3 61181300L1-5C • Installs in both the Total Access 3000 (23-inch) and the Total Access (19-inch) chassis. • End-to-end transmission for one to four DS1 circuits •.
61181300L1-5C Section 61181300L1-5C, Issue 3 3 Table 3. Pin-out For Pair 5 and 7 on TA 3000 Table 4. Pin-out For Pair 6 and 8 on TA 3000 r o l o C p u o r G r e d n i Br o l o C e r i Wn i P P M A n i.
4 Section 61181300L1-5C, Issue 3 61181300L1-5C If the system is configured with only QFO-Cs, all four DSX-1 connections are made. The connections are made via four Amphenol connectors to Pair 5 through Pair 8 on the backplane.
61181300L1-5C Section 61181300L1-5C, Issue 3 5 If no protection switching is provided, the Main unit plugs into any odd-numbered slot. The next higher even-numbered slot may contain a blank card or can be left empty. See Figure 2 . Installing the QFO-C 1.
6 Section 61181300L1-5C, Issue 3 61181300L1-5C Release the card retention lever and carefully seat the card into the backplane connector by firmly pressing on the QFO-C front panel. Verify the fiber cables move freely between the cable guides and the shelf.
61181300L1-5C Section 61181300L1-5C, Issue 3 7 Table 7 . QFO-C Card Provisioning The card is provisioned through the craft port on the SCU or by the FCD. Detailed procedures for provisioning the QFO-C start on page 11 with the section labeled Fiber (QFO-C) Main Menu.
8 Section 61181300L1-5C, Issue 3 61181300L1-5C Option Description Service State Enables normal connection to the DSX or multiplexer interface Loops will train up but will not connect to the DSX or mul.
61181300L1-5C Section 61181300L1-5C, Issue 3 9 • ESCAPE – press the switch in the MODE direction and release it between 1.5 seconds and 3 seconds to ascend the menu tree. • ROOT - press the switch in the MODE direction and release it after 3 seconds to return to the first element of the Level 1 card menu.
10 Section 61181300L1-5C, Issue 3 61181300L1-5C Figure 4. QFO-C FCD Menu Tree STAT VIEW PROV SRVC STAT DEX EQ LB TOUT AIS TO DSX LOS AIS TO DSX FLOS DSBL ENBL SAVE NO SAVE YES NO DONE ES SES UAS 15 MIN ERR THLD P1 P2 P3 P4 P1 P0 P2 P3 P4 IN SRVC Level 3 ESCAPE (1.
61181300L1-5C Section 61181300L1-5C, Issue 3 11 Table 9. QFO-C Menu Hierarchy QFO-C Main Menu Configuration Provisioning Service State Port 0/1/2/3/4 All Provisioning DSX Equalization Loop Back Timeou.
12 Section 61181300L1-5C, Issue 3 61181300L1-5C Shelf: Slot: 10 Total Access System 07/15/99 10:37 Unacknowledged Alarms: MINOR QFO-C Main Menu 1. Configuration 2. Provisioning 3. Status 4. Alarms 5. Test 6. Performance Monitoring 7. Protection Switching 8.
61181300L1-5C Section 61181300L1-5C, Issue 3 13 Figure 8. Service State Screen Shelf: Slot: 10 Total Access System 07/15/99 10:42 Unacknowledged Alarms: None Service State 1. Port 0 Out of Service - Unassigned 2. Port 1 Out of Service - Unassigned 3. Port 2 Out of Service - Unassigned 4.
14 Section 61181300L1-5C, Issue 3 61181300L1-5C Figure 10. Provisioning of All Ports Screen Shelf: Slot: 10 Total Access System 07/15/99 10:45 Unacknowledged Alarms: MINOR Provisioning for All Ports 1. DSX Equalization 0 to 133' ABAM 2. Loopback Timeout 120 Min.
61181300L1-5C Section 61181300L1-5C, Issue 3 15 NOTE Port 0 (all ports) “Out of Service” disables the entire module. Port 0 must be “In Service” for any Port 1 to 4 to be active. Changing the DSX Equalization 1. From the Provisioning of All Ports screen, type “1” and press Enter to select DSX Equalization.
16 Section 61181300L1-5C, Issue 3 61181300L1-5C Figure 13. AIS to DSX (Loss of T1) Shelf: Slot: 10 Total Access System 07/15/99 10:43 Unacknowledged Alarms: None AIS to DSX (Loss of T1): Disabled 1. Disabled 2. Enabled Selection: ‘?’ - System Help Screen Figure 14.
61181300L1-5C Section 61181300L1-5C, Issue 3 17 Figure 15. Restore Factory Defaults Screen Shelf: Slot: 10 Total Access System 07/15/99 10:43 Unacknowledged Alarms: None Restore Factory Defaults? 1. No 2. Yes Selection: ‘?’ - System Help Screen Figure 16.
18 Section 61181300L1-5C, Issue 3 61181300L1-5C Shelf: Slot: 10 Total Access System 07/15/99 10:43 Unacknowledged Alarms: None Status of All Ports Near End Far End Fiber Loss No No Laser Bias Alarm No.
61181300L1-5C Section 61181300L1-5C, Issue 3 19 Shelf: Slot: Total Access System 02/18/98 02:24:18 Unacknowledged Alarm: None Alarms Level ––––––––––––––––––––.
20 Section 61181300L1-5C, Issue 3 61181300L1-5C Shelf: Slot: Total Access System 02:24:18 02/18/98 Unacknowledged Alarm: None ES Threshold (15 Min.): 30 1. 30 2. 150 Selection: ? - System Help Screen Figure 22. ES Threshold (15-Minute) Screen Changing Alarm Settings and Thresholds 1.
61181300L1-5C Section 61181300L1-5C, Issue 3 21 Figure 24. UAS Threshold (15-Minute) Screen Shelf: Slot: Total Access System 02/18/98 02:24:18 Unacknowledged Alarms: None UAS Threshold (15 Min.): 15 1. 15 2. 75 Selection: ‘?’ - System Help Screen Figure 23.
22 Section 61181300L1-5C, Issue 3 61181300L1-5C Figure 25. ES Threshold (24-Hour) Shelf: Slot: Total Access System 02:24:18 02/18/98 Unacknowledged Alarm: None ES Threshold (24 Hour): 14400 1. 2880 2. 14400 Selection: ? - System Help Screen Figure 26.
61181300L1-5C Section 61181300L1-5C, Issue 3 23 Figure 28. Test Screen Shelf: Slot: Total Access System 02/18/98 02:24:18 Unacknowledged Alarms: None Test 1. Port 1 Loopback 2. Port 2 Loopback 3. Port 3 Loopback 4. Port 4 Loopback Selection: ‘?’ - System Help Screen Figure 27.
24 Section 61181300L1-5C, Issue 3 61181300L1-5C Figure 29. Port Test Screen Shelf: Slot: Total Access System 02:24:18 02/18/98 Unacknowledged Alarms: None Loopback RT: Disabled 1. Disabled 2. Network 3. Dual Selection: ‘?’ - System Help Screen Figure 30.
61181300L1-5C Section 61181300L1-5C, Issue 3 25 Figure 32. Performance Monitoring Screen Shelf: Slot: Total Access System 02:24:18 02/18/98 Unacknowledged Alarms: None Peformance Monitoring 1. Port 1 (Near End) 2. Port 2 (Near End) 3. Port 3 (Near End) 4.
26 Section 61181300L1-5C, Issue 3 61181300L1-5C Shelf: Slot: Total Access System 02/18/98 02:24:18 Unacknowledged Alarms: None APS Switching 1. ACT Activate Selection: ‘?’ - System Help Screen Figure 34.
61181300L1-5C Section 61181300L1-5C, Issue 3 27 Shelf: Slot: Total Access System 02/18/98 02:24:18 Unacknowledged Alarms: None Circuit ID 1. Port 1 2. Port 2 3. Port 3 4. Port 4 Selection: ‘?’ - System Help Screen Figure 36. Circuit ID Screen 2. Type “2” and press Enter to switch the Working QFO-C to protect ( Figure 35 ).
28 Section 61181300L1-5C, Issue 3 61181300L1-5C 2. Type the number of the corresponding port whose Circuit ID is to be set or changed and press Enter. The Port Current Circuit ID Screen (Figure 37) will display. 3. Type the new Circuit ID and press Enter.
61181300L1-5C Section 61181300L1-5C, Issue 3 29 Table 10. QFO-C Specifications DS1 Input Level .............................................................. 0 to -9 dBm Output Level ........................................................... 0 dB with DSX buildout from 0 to 655 ft.
30 Section 61181300L1-5C, Issue 3 61181300L1-5C.
デバイスADTRAN QFO-Cの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
ADTRAN QFO-Cをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはADTRAN QFO-Cの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。ADTRAN QFO-Cの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。ADTRAN QFO-Cで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
ADTRAN QFO-Cを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はADTRAN QFO-Cの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、ADTRAN QFO-Cに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちADTRAN QFO-Cデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。