INSTRUCTION MANUAL CS1 15 Barometric Pressure Sensor 3/03 Copyright (c) 2002-2003 Campbell Scientific, Inc..
Warranty and Assistance The CS115 BAROMETR IC PRESS URE SE NSOR is w arranted by CAMPBELL SCIENTIFIC, INC. to be f ree from def ects in m aterials and workmanship und er no rmal use a nd ser vice fo r twelve ( 12 ) months fr om date of shipment unle ss spec ified othe rwise.
i CS115 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to specific sections. 1. Introducti on ......................................................
This is a blank page..
1 CS115 Barometric Pressure Sensor The CS115 Barometric Pressure Sensor us es the resonant silicon technology pressure sensor developed by Druck. The sensor outputs a variable frequency which can be measured using the datalogger' s period averaging instruction or pulse count instruction.
CS115 Barometric Pr essure Sensor 2 2. Specifications 2.1 Performance Measurem ent R ange: 600 mb t o 1100 mb (hPa) Operating Tem perature Range: -40°C to +60°C Hum idity Ran ge: non- condens ing Media Compatibility: non-corrosive gas Total Accuracy 1 : at 20°C ±0.
CS115 Barometric Pr essure Sensor 3 3. Installation 3.1 Venting and Condensati on To p revent condensation, install the se nsor in an en vironm entally protected enclosure, com plete w ith desiccant w hich should be chan ged at regular intervals.
CS115 Barometric Pr essure Sensor 4 As y ou m ount the sen sor onto the back plate of the enclosu re, place the fork lu g under the m ountin g screw to accomplish the proper groun ding of the s ensor as show n i n Fig ure 3-1. 3.3 Jumper Settings The CS115 ha s tw o operating m odes, ‘ contin uous’ and ‘tri ggered’ .
CS115 Barometric Pr essure Sensor 5 4. Wiring The CS115 w iring instru ctions f or the exam ple program s are sh own in Table 4-1. For datal oggers C R500, CR510, C R10(X), CR 23X, and CR5000, analog ch annel is us ed for period averagin g meas uremen t.
CS115 Barometric Pr essure Sensor 6 Once th e CS115 is tu rned on one m inu te before every hour, an d the correct measu rement is m ade, it is then copied into the current variable called "Pressure" . The sensor is then turned off im m ediately follow ing the meas uremen t.
CS115 Barometric Pr essure Sensor 7 5.1 Period Averaging Measurement Examples 5.1.1 Period Averaging Measurement Example fo r CR10(X) EXAMPLE 1. Sam ple Program for CR 10(X) ;{CR 10X} ; *Table 1 Prog .
CS115 Barometric Pr essure Sensor 8 8: Sam ple (P70) 1: 1 Reps 2: 1* Loc [ P_m b ] *Table 2 Prog ram 02: 0.0000 Execution In terval (secon ds) *Table 3 S ubroutin es End Program -Input Loca tio ns- 1 P_m b * Proper entries w ill vary w ith program an d datalogger channel, and input location assign ments.
CS115 Barometric Pr essure Sensor 9 ;T urn off CS1 15 ; 4: Do (P86) 1: 58* Set Port 8* Low 5: If tim e is (P92) 1: 0 Minutes (Secon ds --) in to a 2: 60 Interval (sam e un its as above) 3: 1 0 Set Out.
CS115 Barometric Pr essure Sensor 10 3: Period A verage (SE) (P27) 1: 1 Reps 2: 14 200 kHz Max Freq @ 500 m V Peak to Peak, F req Output 3: 24* SE Chan nel 4: 10 No. of Cy cles 5: 5 Timeou t (unit s = 0.01 seconds) 6: 1* Loc [ P_m b ] 7: 1000 Mult 8: 0.
CS115 Barometric Pr essure Sensor 11 5.1.4 Period Averaging Measurement Example fo r CR5000 in a Fast Executing Program at 10Hz EXAMPLE 4. Sam pl e Program for C R5000 ‘CR5000 ' 'Sample Pr.
CS115 Barometric Pr essure Sensor 12 5.2 Pulse Count Measure ment Exampl e 5.2.1 Pulse Count Measu rement Example for 21X EXAMPLE 5. Sam ple Program for 21X ;{21X} ; *Table 1 Prog ram 01: 1 Execution .
CS115 Barometric Pr essure Sensor 13 *Table 3 S ubroutin es End Program -Input Loca tio ns- 1 P_mb 1 1 1 * Proper entries w ill vary w ith program an d datalogger channel, and input location assign ments.
CS115 Barometric Pr essure Sensor 14 The corrections in volved can be signi ficant: e.g ., at 1000 mb an d 20°C, barometric pressure w ill decrease by 1.1 mb for ev ery 10 meter in crease in altitude. 7. Maintenance and Calibration Since the sen sor is sem i-sealed, m inim um m aintenan ce is required.
Thi s is a b lank p age ..
Campbell Scie ntific Com panies Campbell Scientific, Inc. (CS I) 815 West 1 800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campb ellsci.com Campbell Scientif ic Africa Pty. Ltd. (CSAf) PO B ox 24 50 Somers et West 7129 SOUTH AFRICA www.
デバイスCampbell Hausfeld CS115の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Campbell Hausfeld CS115をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCampbell Hausfeld CS115の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Campbell Hausfeld CS115の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Campbell Hausfeld CS115で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Campbell Hausfeld CS115を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCampbell Hausfeld CS115の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Campbell Hausfeld CS115に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCampbell Hausfeld CS115デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。