ADTRANメーカーT200 FNIDの使用説明書/サービス説明書
ページ先へ移動 of 16
1 Section 61245201L1-5, Issue 3 61245201L1-5C FNID and T200 FNID Fractional T1 Network Interface Device Installation and Maintenance CONTENTS 1. GENERAL ............................................................................ 1 2. INSTALLATION ...
2 Section 61245201L1-5, Issue 3 61245201L1-5C With the exception of the physical dimensions of the units, the FNID and T200 FNID units are functionally identical. The FNID terminates local loop DSL signals originating from the Central Office (CO) unit and transforms the DSL signal into fractional T1 signals to be delivered to the customer.
3 Section 61245201L1-5, Issue 3 61245201L1-5C 3. CONNECTIONS All connections of the FNID are made through card edge connectors. Table B gives the card edge pin assignments for the FNID circuit pack.
4 Section 61245201L1-5, Issue 3 61245201L1-5C 5. CONTROL PORT OPERATION The FNID provides a faceplate-mounted DB9 connector that supplies an RS-232 interface for connection to a controlling terminal. The pinout of the DB9 is illustrated in Figure 4. The terminal interface operates at data rates from 2.
5 Section 61245201L1-5, Issue 3 61245201L1-5C From the Main menu the following screens can be accessed. 1. Current System Status 2. Performance History 3.
6 Section 61245201L1-5, Issue 3 61245201L1-5C A measure of signal quality for each HDSL loop is displayed in graphic form on the bottom right and left of the screen.
7 Section 61245201L1-5, Issue 3 61245201L1-5C Figure 5. Introductory Menu Screen ADTRAN 901 Explorer Boulevard Huntsville, Alabama 35806-2807 For Information or Technical Support, Normal Support Hours ( 7am - 7pm CST ) or Emergency Support Hours ( 7x24 ) Voice Toll Free: 800.
8 Section 61245201L1-5, Issue 3 61245201L1-5C Figure 7. Current System Status Screen FT1-DP CURRENT SYSTEM STATUS FNID NETWORK (DSL) ELAPSED TIME 00:08:18 CUSTOMER (DSL) ---------------------- -------.
9 Section 61245201L1-5, Issue 3 61245201L1-5C Figure 9. Loopback Options Screen LOOPBACK OPTIONS FT1-DP FNID _____ _____ | | | | | | | | —-->| | | |<—- | | | | NET | |<===================.
10 Section 61245201L1-5, Issue 3 61245201L1-5C Figure 11. Provisioning Options Screen PROVISIONING ___________________________________________________ ______________________ | | | | PROVISIONS CURRENT SETTINGS | HARDWARE SETTINGS | | ------------------------------------------ | ----------------- | | 1.
11 Section 61245201L1-5, Issue 3 61245201L1-5C Figure 13. DSL Deployment Guidelines 6. DSL DEPLOYMENT GUIDELINES The ADTRAN FT1 DSL system is designed to provide Fractional DS1-based services over loops designed to comply with Carrier Service Area (CSA) guidelines.
12 Section 61245201L1-5, Issue 3 61245201L1-5C 7. TROUBLESHOOTING PROCEDURES Table E is a troubleshooting guide for the FNID. 8. MAINTENANCE The ADTRAN FNID requires no routine maintenance. In case of equipment malfunction, use the faceplate Bantam jack connectors to help locate the source of the problem.
13 Section 61245201L1-5, Issue 3 61245201L1-5C Loop Interface: Modulation Type ................................................. 2B1Q Mode .................................................................... Full Duplex, Echo Cancelling Number of Pairs .
A-1 Section 61245201L1-5, Issue 3 61245201L1-5C Appendix A FT1 Loopbacks 1. GENERAL This Appendix is an overall reference to the loopback capabilities of the ADTRAN Fractional T1 system. Included in this Appendix is a description of the FT1 loopbacks and the methods for activating the FT1 loopbacks.
A-2 Section 61245201L1-5, Issue 3 61245201L1-5C There is one loopback available to the FT1 Repeaters. The FT1 Repeater Network loopback is a digital loopback toward the CO as shown in Figure A-4. The loopbacks are initiated by the DDS latching loopback codes for NEI Position 1 (N1000001) for FT1 #1 or NEI Position 2 (N100001) for FT1 Repeater # 2.
A-3 Section 61245201L1-5, Issue 3 61245201L1-5C 3. LOOPBACK ACTIVATION/DEACTIVATION This section describes loopback activation and deactivation methods for the ADTRAN Fractional T1 system. Loopback activation and deactivation is controlled with the push-button located on the front panel, through craft interface, or latching loopback codes.
デバイスADTRAN T200 FNIDの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
ADTRAN T200 FNIDをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはADTRAN T200 FNIDの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。ADTRAN T200 FNIDの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。ADTRAN T200 FNIDで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
ADTRAN T200 FNIDを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はADTRAN T200 FNIDの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、ADTRAN T200 FNIDに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちADTRAN T200 FNIDデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。