Carrierメーカー40QA024-060の使用説明書/サービス説明書
ページ先へ移動 of 24
Manufacturer reserves the right to disco ntinue, or change at any time, specifications or de signs without notice and without inc urring obligations. Catalog No .
2 T able 1 — Syst em Matches *Units must be field reconfigured for 1 1 / 2 ton (18,000 Btuh) operation. See Bef ore Installation sec- tion on page 3 for details . NO TE: Numbers in ( ) indicate quantities when ther e is more than one fan coil unit in the system.
3 T able 3A — Physical Data, Unde r Ceiling Cooling Only Units *Field reconfigured to 18,000 Btuh (1 1 / 2 tons). See Before Installa- tion section on this page for details. † The valv e connection size is 7 / 8 inch. The recommended line size is 1 1 / 8 inch.
4 T able 3B — Physical Data , Under Ceiling Heat Pump Units *Field reconfigured to 18,000 Btuh (1 1 / 2 tons). See Before Installa- tion section on page 3 for details. †The valv e connection size is 7 / 8 inch. The recommended line size is 1 1 / 8 inch.
5 Fig. 3 — Base Unit Dimensions UNIT SIZE WEIGHT (lb) A B E F G Cooling Only Heat Pump ft-in. mm ft-in. mm ft-in. mm ft-in. mm ft-in. mm 024 108 110 4- 2 15 / 16 1294 3-10 1169 4- 1 5 / 8 1260 — .
6 5. Run refrigerant piping as directly as possi ble and avoid any unnecessary turns or bends. 6. Condensate piping can b e directed t hrough the insi de wall to an approved drain or straight outside. NOTE: The piping hole for condensate line must slope at a minimum pitch of 1 / 4 in.
7 TO I NST ALL THERMOST A T : If there is at least 3 / 8 in. of space between the back of indoor unit and wall: 1. Route thermostat wires (field-supplied) throu gh slot in right side or rear panel of indoo r unit (Fig. 3). 2. Route wires over refrigerant and drain piping as shown in Fig.
8 f. Refer to the outdoor unit Installation, Start-Up and Service Instructions for add itional information . g. Install a factory-supplied filter drier near the out- door unit. On heat pump systems, a bi-flow filter drier must be used. 3. Insulate and caulk wall ope nings to reduce air in filtra- tion and refrigerant pipe vibrations on structure.
9 Fig. 10 — Mounting Hanging Brac kets Fig. 11 — Hanging F a n Coil Unit *Field-supplied. Fig. 12 — Routing Wires Over Piping NO TE: T eflon Seal must face tow ard the outdoor heat p ump unit.
10 Step 6 — Make Electrical Con nections — Be sure field wiring complies with local building codes and NEC, and unit voltage is within limits shown in T able 5. Contact local power company for correction of improper line voltage. NOTE: Use copper wire only between disconnect switch(es) and unit.
11 Fig. 14 — Component Location (T ypical Ceiling-Suspended System) LEGEND *Standard. †Accessory item. **Field supplied. ††Insulate for heat pump application. NO TE S: 1. All piping must follo w standard refr igerant piping techniques. 2. All wiring must comply with the applicab le local and national codes.
12 Step 7 — Install Thermostat — These systems use a 3-speed thermostat. The thermostat monitors the system opera- tion and controls the operating mode. T o change settings or re- fer to the thermostat Operating Instructions. Mount thermostat to a wall in the occupied space using 2 field-supplied screws.
13 Step 8 — Make Connections Between Indoor and Outdoor Units — The thermostat is wired between the indoor and outdoor units to make the system com plete. CHECK ACCURA TER METERING DEVICE — Th e co r- rect AccuRater (bypass type) refri gerant control is required for system capacity optimization.
14 AUTO COOL HEA T COOL HEA T AUTO FLA T THERMO ST A T (FLA TST A T) CARRIER COOLING ONL Y HEA T & COOL (53DFS250-FS) SLIMLINE THERMOST A T CARRIER HEA T PUMP COOLING ONL Y HEA T & COOL (53DFS250-SL ) 5-1-1 PROGRAMMABLE THERMOST A T CARRI ER COOLING ONL Y HEA T & COOL (53DFST2-NP) Fig.
15 Step 8 — Make Connections Between Indoor and Outdoor Units — The thermostat is wired between the indoor and outdoor units to make the system com plete. CHECK ACCURA TER METERING DEVICE — Th e co r- rect AccuRater (bypass type) refri gerant control is required for system capacity optimization.
16 Fig. 20 — Coolin g System Wiring Diagram.
17 Fig. 21 — He at Pump Wiring Dia gram.
18 ST AR T -UP Make the following checks and complete the Start-Up Checklist on page CL-1 before system start-up. Also refer to the condensing unit Installation, S tart-Up and Service Instruc- tions for system start-up instructions and refrigerant charging methods.
19 SPECIAL OPERA TION, HEA TING — Outdoor cooling units may be matched with heat pump ceiling-suspended fan coil units to provide supplemental electric heat.
20 Clean Indoo r Unit Bottom Panel — If the bottom panel of the unit becomes dirty or smudged, wipe the outside of the panel with a soft dry cloth. Use a mild liquid deter gent and wipe off carefully with a dry cloth.
21 T able 7 — T r oubleshooting *If fuse blo w s or circuit breaker trips again after firs t star t attempt, DO NO T attempt to star t system again. Contact your local dealer f or assistance.
Manufacturer reserves the right to disco ntinue, or change at any time, specificatio ns or designs without notice and without inc urring obligations. Catalog No .
ST A RT -UP CHECKLIST I. PRELIMINAR Y INFORMA TION OUTDOOR UNIT : MODEL NO. ___________________ INDOOR UNIT : MODEL NO. _____________________ SERIAL NO.
Manufacturer reserves the right to disco ntinue, or change at any time, specificatio ns or designs without notice and without inc urring obligations. Catalog No .
デバイスCarrier 40QA024-060の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Carrier 40QA024-060をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCarrier 40QA024-060の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Carrier 40QA024-060の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Carrier 40QA024-060で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Carrier 40QA024-060を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCarrier 40QA024-060の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Carrier 40QA024-060に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCarrier 40QA024-060デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。