Carrierメーカー50AH024-096の使用説明書/サービス説明書
ページ先へ移動 of 20
Manufacturer reserves the right to disco ntinue, or change at any time, specifications or de signs without notice and without inc urring obligations. Catalog No . 04-53500057-0 1 Printed in U. S.A. F orm 50AH-14SI Pg 1 5-10 Replaces: 50AH-12SI Installation, Star t-Up , and Ser vice Instructions CONTENTS SAFETY CONSIDERA T IONS .
2 Evaporator Confi g uration Factory-In s talled Option s 50AH AC 04 8 5 – – – – 2 1 XX 50AH – Horizont a l, Indoor S ingle-P a ck a ge Cooling Unit Packa g in g 1 – Dome s tic 2 – Expor.
3 DET AIL A CLEARANCE HOLE FOR 3 /8" HANGING ROD TYP 8 PL S AIR IN COIL ACCE SS FRONT TOP RIGHT REAR LEFT RETURN AIR S UPPL Y AIR AIR OUT MOT OR ACCE SS ELECT BO X ACCE SS BLOWER ACCE SS EV AP S .
4 64 1/2 6 1/ 8 1 83 /4 1 3 /4 16 1/ 8 1 1/2 3 1 3 /16 1 15/16 44 1/ 8 3 7/ 8 38 1/ 8 6 1/16 24 3 /4 38 1/2 5 15/16 3 1/4 3 1/4 5 7/ 8 1 3 5/ 8 9 5/16 12 3 / 8 6 7/16 2 1/4 5 7/ 8 12 0 lb s . Fig. 3 — Unit Dimensions — 50AH024-060 Units wi th F actory-Instal led Air -Side Economizer a50-8548 NO TES: 1.
5 DET AIL A CLEARANCE HOLE FOR 3 /8" HANGING ROD TYP 8 PL S DET AIL "A" AIR IN MOT OR ACC ELECT BOX ACCE SS COIL ACCE SS COMPRE SS OR ACCE SS FIL TER ACCE SS CONDEN S A TE DRAIN 7/8&quo.
6 1 3 7/16 16 1/16 6 7/16 1 8 3 /4 6 5/ 8 70 1/2 3 1/4 2 1/4 5 7/ 8 22 1/ 8 21 7/16 1 8 15/16 10 7/ 8 3 1/4 5 15/16 1 1/2 72 1/2 1 15/16 61 1/ 8 3 7/ 8 4 3 1/ 8 6 1/16 42 1/2 29 3 /4 12 NO TES: 1. Dimensions are in inches. 2. Economizer weight is 200 l b s.
7 Table 1 — Physical Data LEGEND * Shipping weigh ts include b ase unit plus packag ing. †If componen ts are to b e split, addi tional refrigera nt will b e needed.
8 Table 1 — Ph ysical Data (cont) LEGEND * Shipping weigh ts include b ase unit plus packag ing. †If componen ts are to b e split, addi tional refrigera nt will b e needed.
9 Condensing section must be located in same plane as, or above, evaporator section to main tain the liquid refrigerant seal at the expansion device. This permits expansion device to feed liquid refrigerant to evaporator coil properly . T o split sections (some of the following steps may be eliminated depending on particular application): 1.
10 of the tubing. Use a 1 / 4 -in. hole to mount the valve. Clean and debur the tubing before doing any brazing to ensure that no chips or debris are left in the refrigerant circuit. Remove the Schrader valve cap and core before doing any brazing. 5. After brazing the tubing to the self-sealing coupling halves, evacuate each line to 500 microns.
11 Table 2B — Electrica l Data — Upgrade 1 Evapora tor Motor with Standar d Condenser Motor Table 2C — Electrica l Data — Upgrade 2 Evapora tor Motor with Standar d Condenser Motor LEGEND UNIT.
12 Table 2D — Electrical Data — Upgra de 3 Evaporator Motor with Sta ndard Condenser Motor Table 2E — Electric al Data — Standard Evaporator Moto r with Upgrade 1 Condenser Motor LEGEND UNIT 5.
13 Table 2F — Elect rical Data — Upg rade 1 Eva porator Motor with Upgr ade 1 Condenser Motor Table 2G — Electric al Data — Upgrade 2 Evapo rator Motor with Upgrade 1 Condenser Motor LEGEND UN.
14 Table 2H — Electrical Data — Upg rade 3 Ev aporator Mo tor with Upg rade 1 Con denser Moto r Table 2I — Electrica l Data — Standard Evapo rator Motor with Upgrade 2 Condenser Motor LEGEND U.
15 Table 2J — Electrical Data — Upgrade 1 Eva porator Motor with Upgrade 2 Condense r Motor Table 2K — Electrical Data — Upg rade 2 Evap orator Mot or with Upgr ade 2 Conde nser Motor LEGEND U.
16 Table 2L — Elect rical Data — Upgrad e 3 Evaporator Moto r with Upgrade 2 Cond enser Motor LEGEND Table 3 — Evaporator-Fan Performa nce LEGEND NO TES: 1. Refer to T a b le 1 f or ev aporator f an motor and dr ive inf ormation. 2. Upgrade 1 Static Motor is required for boldface valu es.
17 Table 4 — Co ndenser-Fan Performance LEGEND NO TES: 1. Refer to T a b le 1 f or condenser fan motor and drive inf or mation. 2. Upgrade 1 Static Motor is required for boldface valu es.
18 Blower Belt Adjustment — Inspect blower belt for wear , proper belt tension, and pulley alignment as conditions require or at the beginning of each heating and air conditioning season. Make sure that fan shafts and motor shafts are parallel and level.
.
Manufacturer reserves the right to disco ntinue, or change at any time, specificatio ns or designs without notice and without inc urring obligations. Catalog No .
デバイスCarrier 50AH024-096の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Carrier 50AH024-096をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCarrier 50AH024-096の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Carrier 50AH024-096の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Carrier 50AH024-096で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Carrier 50AH024-096を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCarrier 50AH024-096の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Carrier 50AH024-096に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCarrier 50AH024-096デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。