Carrierメーカー58CMAの使用説明書/サービス説明書
ページ先へ移動 of 12
58CMA Series 130 Multipoise Oil Furnace Installation, Start-up, and Operating Instructions NOTE: Read the entire instruction manual before starting the installation. This symbol → indicates a change since last issue. TABLE OF CONTENTS SAFETY CONSIDERATIONS .
ANSI/NFPA 31: INSTALLATION OF OIL BURNING EQUIPMENT ANSI/NFPA 211: CHIMNEYS, FIREPLACES, VENTS, AND SOLID FUEL BURNING APPLIANCES ANSI/NFPA 90B: WARM AIR HEATING AND AIR CONDITIONING SYSTEMS ANSI/NFPA 70: NATIONAL ELECTRICAL CODE CSA B139: INSTALLATION CODE FOR OIL BURNING EQUIPMENT CAS C22.
The air handling capacity of this furnace is designed for cooling airflow. Refer to Table 12 for expected airflows at various external duct static pressures. LOCATION Step 1 — General This furnace is not water tight and is not designed for outdoor installation.
Do not block combustion-air openings in the furnace. Any blockage will result in improper combustion which may result in a fire hazard and/or cause bodily harm.
opening must have a free area of at least 1 sq in. per 1000 Btuh of total input rating but not less than 100 sq in. (See Table 4.) ALL AIR FROM OUTSIDE OF STRUCTURE If outside air is supplied to a confined space, then the 2 openings must be equal and located as above.
2. Inspection to ascertain that vent system is clear and free of obstructions. Any blockage must be cleared before installing furnace. 3. Cleaning chimney or vent if previously used for venting a solid fuel burning appliance or fireplace. 4. Confirming that all unused chimney or vent connections are properly sealed.
24-V Wiring Instructions for wiring thermostat (field supplied) are packed in thermostat box. Make thermostat connections as shown in Fig. 3 or 4 at 24-v terminal board on fan timer board. Accessories When installing optional accessories to this appliance, follow manufacturer ’ s Installation Instructions included with accessory.
Fig. 3 — Wiring Diagram (105-12) A03164 X04031 Rev. A 8.
Fig. 4 — Wiring Diagram (120-20) A03165 X04032 Rev. A 9.
c. Use of an oversized nozzle input. d. Pump pressure over values listed in Table 10. 5. The CO 2 and stack temperature instruments enable you to obtain data required to determine thermal efficiency of fur- nace. 6. An oil filter should be installed as close to burner as possible with ALL oil burners and is essential on lower firing rate burners.
MAINTENANCE The ability to properly perform maintenance on this equip- ment requires certain expertise, mechanical skills, tools, and equipment. If you do not possess these, do not attempt to perform any maintenance on this equipment other than those procedures recommended in the User ’ s Manual.
4. Remove cover from control box and disconnect thermostat and power wires from the board. 5. Slide blower forward on rails toward front of unit. 6. Reverse items 1 through 5 to re-install blower. Refer to wiring diagram (Fig. 3 or 4) of these instructions or diagram located on inside of blower door to properly rewire unit.
デバイスCarrier 58CMAの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Carrier 58CMAをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCarrier 58CMAの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Carrier 58CMAの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Carrier 58CMAで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Carrier 58CMAを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCarrier 58CMAの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Carrier 58CMAに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCarrier 58CMAデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。