SKU 94275 For technical questions, please call 1-800-444-3353. P A GE 1 INST ALLA TION AND OPERA TING INSTRUCTIONS Due to continuing improv ements, actual product ma y diff er slightly from the product described herein. 3491 Mission Oaks Blvd., Camarillo , CA 93011 Visit our W eb site at: http://www .
SKU 94275 For technical questions, please call 1-800-444-3353. P A GE 2 PR ODUCT SPECIFICA TIONS SA VE THIS MANU AL Y ou will need this manual f or the safety warnings and precautions, assembly , ope ra tin g, i ns pec ti on, ma in ten an ce and c leani ng pr oc ed ure s, parts lis t and asse mb ly diag ram.
SKU 94275 For technical questions, please call 1-800-444-3353. P A GE 3 ELECTRICAL SAFETY 4. Grounded tools m ust be plugged into an outlet properl y installed and grounded in accor dance with all codes and ordinances. Never remo ve the grounding pr ong or modify the plug in any wa y .
SKU 94275 For technical questions, please call 1-800-444-3353. P A GE 4 12. A void accidental starting. Be sure the P ower Switch is off bef ore plugging in. Plugging in power tools with the P o wer Switch on, invites accidents . 13. Remove adjusting ke ys or wrenches before turning the po wer tool on.
SKU 94275 For technical questions, please call 1-800-444-3353. P A GE 5 SPECIFIC SAFETY R ULES This Dust Reclaimer Kit is designed f or use only with Model 94274. 1. Use the right product f or the job. 2. Do not attempt to f orce small tools and equipment to do the work of larger tools and equipment.
SKU 94275 For technical questions, please call 1-800-444-3353. P A GE 6 11. Alwa ys unplug the Dust Reclaimer fr om its electrical outlet bef ore performing an y maintenance or changing accessories. 12. Do not use the Dust Reclaimer with an y openings blocked.
SKU 94275 For technical questions, please call 1-800-444-3353. P A GE 7 GR OUNDING W ARNING! GROUNDED T OOLS: T OOLS WITH THREE PRONG PLUGS T ools marked with “Grounding Required” ha v e a three wire cord and three prong 1. grounding plug. The plug must be connected to a proper ly grounded outlet.
SKU 94275 For technical questions, please call 1-800-444-3353. P A GE 8 EXTENSION CORDS DOUBLE INSULA TED TOOLS: T OOLS WITH TWO PR ONG PLUGS T ools marked “Double Insulated” do not require grounding.
SKU 94275 For technical questions, please call 1-800-444-3353. P A GE 9 RECOMMENDED MINIMUM WIRE GA UGE FOR EXTENSION CORDS* (120 OR 240 V OL T) NAMEPLA TE AMPERES (at full load) EXTENSION CORD LENGTH 25 Feet 50 Feet 75 Feet 100 Feet 150 Feet 0 – 2.
SKU 94275 For technical questions, please call 1-800-444-3353. P A GE 10 How T o Install The Dust Reclaimer T o A W all Open the right side doorof the blast cabinet. Remo ve the f our screws on the e x- 1. haust board. T ake out the e xhaust board (see Figure 1).
SKU 94275 For technical questions, please call 1-800-444-3353. P A GE 11 Use the patter n in Figure 3 as a ref erence, or hold the assemb led Dust Reclaimer 4. against the wall where y ou intend to mount it, and mar k the drill hole positions through the mounting holes.
SKU 94275 For technical questions, please call 1-800-444-3353. P A GE 12 Attach the dust reclaimer to the wall using Flat W ashers (35), Spring W ashers 7. (36) and He x Nuts (46). See Figure 5 below . Figure 5 Figure 4 T ap the W all Anchors (33) into the wall using a hammer .
SKU 94275 For technical questions, please call 1-800-444-3353. P A GE 13 Attach the blast cabinet to the Dust Reclaimer as sho wn in Figure 7, then fir mly 9. tighten up the Hose Clamps (15). Figure 7 48 After attaching the Dust Reclaimer to the wall, it should look lik e it does in Figure 8.
SKU 94275 For technical questions, please call 1-800-444-3353. P A GE 14 How T o Install The Dust Reclaimer T o A Blast Cabinet (SKU # 94274) Open the right side doorof the blast cabinet. Remo ve the f our screws on the e x- 1. haust board. T ake out the Exhaust Board (see to Figure 8).
SKU 94275 For technical questions, please call 1-800-444-3353. P A GE 15 Assemble the tw o Suppor t Brac k ets (32) to the Dust Reclaimer Housing (22A) 4. using par ts 28, 29, 30, and 31. Do not tighten up the Nuts (31) completely at this point. See Figure 10 belo w .
SKU 94275 For technical questions, please call 1-800-444-3353. P A GE 16 Some v ersions of SKU 94274 Blast Cabinet do not ha v e the eight pre-drilled 6. mounting holes drilled into the back of the Blast Cabinet (holes are needed to mount the Dust Reclaimer Kit).
SKU 94275 For technical questions, please call 1-800-444-3353. P A GE 17 INSPECTION, MAINTENANCE, AND CLEANING 1. W ARNING! Make sure the P ower Cord Plug (12) of the Dust Reclaimer is unplugged from its electrical outlet before perf or ming any inspection, maintenance, or cleaning procedures .
SKU 94275 For technical questions, please call 1-800-444-3353. P A GE 18 TR OUBLESHOO TING Problem P ossible Solution Dust Reclaimer does not tur n on. Make sure the P ower Switch (25) on is in 1. its “ON” position. Make sure the P ower Cord Plug of the 2.
SKU 94275 For technical questions, please call 1-800-444-3353. P A GE 19 NO TE: Some par ts are listed and shown f or illustration pur poses only , and are not av ailable individually as replacement par ts .
SKU 94275 For technical questions, please call 1-800-444-3353. P A GE 20 P ARTS LIST T HE MANUF ACTURER AND/OR DISTRIBUT OR HAS PRO VIDED THE P AR TS LIST AND ASSEMBL Y DIAGRAM IN THIS MANUAL AS A REFERENCE T OOL ONL Y .
SKU 94275 For technical questions, please call 1-800-444-3353. P A GE 21 90 Day W arranty Harbor Freight T ools Co. makes every ef fort to assure that its products meet high quality and durability sta.
デバイスCentral Pneumatic 94275の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Central Pneumatic 94275をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCentral Pneumatic 94275の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Central Pneumatic 94275の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Central Pneumatic 94275で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Central Pneumatic 94275を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCentral Pneumatic 94275の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Central Pneumatic 94275に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCentral Pneumatic 94275デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。