CFM CorporationメーカーSHR36の使用説明書/サービス説明書
ページ先へ移動 of 24
1384 SHR cov er 5/27/99 djt SHR Series W oodburning Fireplace For Models: SHR36 SHR42A SHR48 SHR52 Underwriter's Laboratories Report No. MH6018 DO NOT DISCARD THIS MANUAL: Retain for future use.
2 SHR Series W oodbur ning Fireplace 20001384 Safety Information PLEASE READ THIS MANUAL BEFORE INST ALLING AND USING FIREPLACE. IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty .
3 SH R Series W oodb urning Fireplaces 20001384 Rough Opening Height 42" (1067mm) 52 " (1327mm) 48 " (1222mm) " " 28 " (724mm) " (189mm) 13 " Dia.
4 SHR Series W oodbur ning Fireplace 20001384 " (724mm) 7 " (197mm ) 48" (1219mm) 58 " (1480mm) 48 " (1232mm) " " " (189mm) 13 " Dia.
5 SH R Series W oodb urning Fireplaces 20001384 FP554A SH Series 1/28/99 djt Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation. FP554A Fig. 5 Fireplace and chase parts identification.
6 SHR Series W oodbur ning Fireplace 20001384 Chimney Requirements - Offset Installations 0 0 0 0 0 3" 1 1" 1 0 0 0 0 8 ¹⁄₄ " 20" 0 1 0 0 0 1 1 ¹⁄₄ " 25 ¹⁄₄ &qu.
7 SH R Series W oodb urning Fireplaces 20001384 Planning Information The T en Foot Rule Major U.S. building codes specify a minimum chimney height above the roof top.
8 SHR Series W oodbur ning Fireplace 20001384 Installation Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30 feet above the hearth. Chimney supports are required if the vertical height exceeds 30 feet with 1 1CF chimneys.
9 SH R Series W oodb urning Fireplaces 20001384 Framing Framing can be constructed before or after the fireplace is set in place, however , most installers build the frame before setting the fireplace. Frame fireplace with 2 x 4 lumber or heavier materials.
10 SHR Series W oodbur ning Fireplace 20001384 FP556SHR Fig. 13 Locate centerline of chimney with plumb line. FP556SHR SHR LOCA TE CENTER LINE 5/11/99 djt Chimney Centerline Actual Centerpoin.
1 1 SH R Series W oodb urning Fireplaces 20001384 The inside dimension of the frame must be the same as the hole size selected from Figure 1 1 in order to provide the required 2 inches of air space between the outside diameter of the chimney and the edges of the framed ceiling hole.
12 SHR Series W oodbur ning Fireplace 20001384 Installing the Chimney System Start by attaching the first chimney section to the collar on top of the fireplace. Install the pipe as pictured in Figure 19. When you get a good lock, you will hear the pipe clearly snap together .
13 SH R Series W oodb urning Fireplaces 20001384 Attic Installation Ceiling Installation Fig. 21 Installing firestop spacer . FP285 IWF285 mbuf 5/25/96 Nails (4) Firestop Spacer Joist J.
14 SHR Series W oodbur ning Fireplace 20001384 Cut and Frame Roof Hole Size of roof hole varies with the type of chimney termi- nation installed. Refer to installation instructions pro- vided with the chimney termination to find correct size roof hole.
15 SH R Series W oodb urning Fireplaces 20001384 FP1166 surround flush with finished wall 12/20/01 djt Stud 2 x 4 Header Ledge Bracket Surround Must be Sealed with Noncombustible Material Noncombus- tible Decorative Facing Finished W all FP1 166 Fig. 26 Fireplace surround flush with finished wall.
16 SHR Series W oodbur ning Fireplace 20001384 FP1167 facing flush with finished wall 12/20/01 djt Finished W all Stud Noncombustible Decorative Fac- ing Must be Sealed with Noncombustible Material Surround 2 x 4 Finished Header Covered W all Ledge Bracket FP1 167 Fig.
17 SH R Series W oodb urning Fireplaces 20001384 Side W all Protection Adjacent combustible side walls that are within dimen- sions shown in Figure 30 of fireplace opening must be protected with W all Shield Model SP40 or a specifically built wall shield described in Figure 29.
18 SHR Series W oodbur ning Fireplace 20001384 FP532SHR Fig. 32 Combustible side wall protection and hearth extension dimensions. Minimum W all Clearances WITH Noncombustible Surround Facing WITHOUT N.
19 SH R Series W oodb urning Fireplaces 20001384 removed from gas line tube to repack space around the pipe. Material should be inserted from outside of the fireplace and packed tightly to totally seal between the pipe and tube.
20 SHR Series W oodbur ning Fireplace 20001384 1384 pts replacement parts 5/27/99 djt 7/14/99 removed clips,added push nut 1 2 3 4 5 6 7 8 a b c 9 10 1 1 d 12 13 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
21 SH R Series W oodb urning Fireplaces 20001384 Description Designed to enclose the fireplace opening with glass doors allowing the fire to remain visible. Available in Polished, Brushed Brass, Black and Pewter Provides outside air for fuel conbustion in the firebox.
22 SHR Series W oodbur ning Fireplace 20001384 Accessory Description Model No. Contemporary Flashing Contemporary Chase T op T ermina- tion Contemporary Round T op T ermina - tion Extended Round T op .
23 SH R Series W oodb urning Fireplaces 20001384 LIMITED W ARRANTY & 30 YEAR PROTECTION PLAN For MAJESTIC FIREPLACES ® PRE-ENGINEERED Fireplace Systems CFM Corporation warrants its MAJESTIC FIREP.
© CFM Corporation 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www .cfmcorp.com CFM Corporation.
デバイスCFM Corporation SHR36の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
CFM Corporation SHR36をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCFM Corporation SHR36の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。CFM Corporation SHR36の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。CFM Corporation SHR36で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
CFM Corporation SHR36を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCFM Corporation SHR36の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、CFM Corporation SHR36に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCFM Corporation SHR36デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。