V ent-Free Gas Room Heaters Homeowner's Installation and Operating Manual PLEASE READ THIS MANUAL BEFORE INST ALLING AND US - ING APPLIANCE. IMPORT ANT : Read all instruc- tions and warnings carefully be- fore starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty .
2 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 Installation & Operating Instructions Important Curing/Burning Instructions ................................................................................. 3 Fireplace Dimensions .
3 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 Installation & Operating Instructions This gas room heater should be installed by a qualified installer in accordance with local building codes and with current Na- tional Fuel Gas Code.
4 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 36" 34 ³⁄₄ " 32 ³⁄₄ " 5 ³⁄₄ " 3 ¹⁄₄ " 7 ³⁄₄ " 2" 21" 1" .
5 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 Safety Devices Adequate combustion and ventilation air must be pro- vided. The flow of combustion and ventilation air MUST NOT be obstructed.
6 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 Hearth Extension A hearth extension in front of heater is recommended but not required. Planning Planning the installation is an important first step: it will save time and money later in the actual installation.
7 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 GF443 UVC (from GF379) 2/11/97 Parts Identification Fig. 6 Parts identification.
8 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 Always check for gas leaks with a mild soap and water solution. Do not use an open flame for leak testing. The gas control is equipped with a captured screw type pressure test point, therefore it is not necessary to pro- vide a 1/8" test point up stream of the control.
9 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 2. Attach wire to switch and install switch into recep- tacle box. Attach cover plate to switch. 3. Connect wiring to gas valve. (Fig. 10) Alternate Switch Location Remote switch can be installed on either side of the access door .
10 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 Glass Information (UVC Only) Only glass approved by CFM Specialty Home Products should be used on this fireplace. • The use of any non-approved replacement glass will void all product warranties.
1 1 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 7. Place top left log (BE9 or BF1 1) onto locator notches. Ensure log is secure.
12 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above.
13 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 • Gas Supply On • Supply line hooked up • Shutoff valve open NO NO NO NO • Lockout has engaged.
14 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out.
15 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 13 12 10 11 8 6a/b 22 18 17 26 7 9 23 a/b 2 3 4a/b 5 25 20a/b 27 15 28 19 1 1a 1b 1c 1d 1e UVC/UVS36 1a 1b 1c 1d 1e UVC/UVS43 1 1.
16 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 Contact CFM Specialty Home Products for questions concerning prices and policies covering replacement parts. Parts may be ordered through your Majestic Fire- places distributor or dealer .
17 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 Optional Accessories Fan Kit FK24 Fan Assembly Fan specifications: 120 volt, 60 Hz, .
18 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 Decorative Frame T rims A selection of decorative frame trim kits are available for mounting around the outside of the appliance to en- hance its visual effect on the room. Installation instruc- tions for each decorative frame trim are included with the frame trim kit.
19 M ajes tic F ir eplaces ® UV C / UVS V ent-Fr ee H eaters 20000135 BASIC W ARRANTY CFM Specialty Home Products (hereinafter referred to collectively as the Company) warrants that your new V ermont.
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts.com • www.vermontcastings.com CFM Specialty Home Products.
デバイスCFM UVC43の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
CFM UVC43をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCFM UVC43の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。CFM UVC43の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。CFM UVC43で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
CFM UVC43を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCFM UVC43の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、CFM UVC43に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCFM UVC43デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。