ChamberlainメーカーLM21XPの使用説明書/サービス説明書
ページ先へ移動 of 16
O O W W N N E E R R ’ ’ S S M M A A N N U U A A L L M M O O D D E E L L L L M M 2 2 1 1 X X P P E E X X T T E E N N D D E E D D P P E E R R F F O O R R M M A A N N C C E E R R E E L L E E A A S S E E D D E E V V I I C C E E The Chamberlain Group, Inc.
When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock.
INTRODUCTION 3 AGENCY REQUIREMENTS Installation and testing to factory specifications shall be performed by factor y authorized personnel for proper operation in accordance with the latest National Fi.
4 INST ALL A TION Classification: Releasing device as defined by Underwriters Laboratories. Installation Requirements: Intended for “Indoor Dry” locations; all wiring must be per formed in accordance with the most current version of NFP A 72 - National Fire Alarm Code and the National Electric Code.
1 2 + 24Vdc from an Approved UL 1481 Regulated Power Supply with Battery Backup – 5 WIRING WIRING INSTRUCTIONS Verify wiring configuration with that recommended by door manufacturer for use of this product with specific door and accessories being utilized.
6 WIRING WIRING DIAGRAM 1 2 3 4 Solenoid (YE) (GY) R6 P2 U4 C2 U2 U3 C4 C1 Field Wiring shall consist of 22-18 A WG wiring. 1. Supervised, power limited circuit, 20 Ohm maximum line impedance. 2. Unsupervised, power limited circuit, 20 Ohm maximum line impedance.
7 CONNECTIONS OF INITIATING DEVICES AND ACCESSORIES A maximum of 4 smoke detectors may be installed with this device. Refer to NFP A 72 and NFP A 80 for instructions concerning proper placement and detection coverage. End-of-line devices must be installed for supervision of electrical power to 4-wire smoke detector .
8 WIRING 5 6 Fire Alarm Control Panel Red Black Common Normally Closed T erminal Strip Relay Module – + FIGURE 7 CONNECTIONS OF INITIATING DEVICES AND ACCESSORIES (cont’d) Relay Module Installation In lieu of smoke detectors, the release device may be put into alarm by the fire alarm control panel.
9 WIRING OPTIONAL CONNECTIONS (cont’d) DIP SWITCH SELECTION The release device will provide a factory default delay of 10 seconds (to minimize nuisance alarms) before releasing the fusible link chain upon alarm or power loss.
10 TESTING TEST PROCEDURES TO BE PERFORMED BY F ACTORY AUTHORIZED PERSONNEL ONL Y! CLEAR FIRE DOOR OPENING AND PROHIBIT TRAFFIC THROUGH DOOR OPENING WHILE TESTING! T esting does not affect normal operation of alarm system when connected to release device/control panel.
N/O Detector T rouble Y ellow (LED 4) If lit, indicates a trouble condition (a short) within the N/O 2-wire (or 4-wire) smoke detector loop (emanating from terminal board positions 3 and 4), resulting from either incorrect wiring or incorrect placement of the end-of-line resistor , and the smoke detector loop is inactive.
Disable Y ellow The Y ellow LED will light when the door reaches the close limit and activates a proximity switch attached to terminal positions 7 and 8 on the release device.
ACCESSORIES REPLACEMENT P ARTS 13 ACCESSORIES AND REPL ACEMENT P ARTS HOW TO ORDER REPAIR PARTS OUR LARGE SERVICE ORGANIZA TION SPANS AMERICA Installation and service information call our TOLL FREE nu.
LM2W-B 24Vdc 2-Wire Photo 2W-B LM2WT -B 24Vdc 2-Wire Photo with Thermal 2WT -B LM4W-B 24Vdc 4-Wire Photo 4W-B LM4WT -B 24Vdc 4-Wire Photo with Thermal & Form C Relay 4WT -B LM1424 24Vdc Ion #1424 .
15 OPERA TOR NOTES.
01-32046B © 2006, The Chamberlain Group, Inc. Issue Date 7/27/2006 All Rights Reserved.
デバイスChamberlain LM21XPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Chamberlain LM21XPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはChamberlain LM21XPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Chamberlain LM21XPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Chamberlain LM21XPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Chamberlain LM21XPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はChamberlain LM21XPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Chamberlain LM21XPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちChamberlain LM21XPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。