Section 319–29E–202 Equipment Issue 2 Third Printing, June 1999 Charles Industries, Ltd. 1999 Charles Industries Ltd. CLEI is a trademark of Bell Communications Research, Inc. All rights reserved. Printed in United States of America. The availability of features and technical specifications herein subject to change without notice.
Section 319–29E–202 2 1. GENERAL 1.1 Document Purpose This document provides general, circuit, and testing information for the Charles Industries Span T ermination Sys- tem (STS) 3192–9E Powering T1 Network Interface Unit (NIU), shown in Figure 1.
Section 319-29E-202 3 2. APPLICA TION ENGINEERING The 3192–9E is ideally suited for use in provisioning T1 High Capacity Digital Service (HCDS) from lightwave-fed building Remote T erminals located at customer premise locations. See Figure 2 for a typical application.
Section 319–29E–202 4 The 3192–9E input current is highly dependent on application. Those applications that require the 3192–9E to power a customer ’s CSU will require a greater input current. T able 1 shows input current and heat release versus the equivalent series simplex resistance (at 60mA) present on the CI side of the unit.
Section 319-29E-202 5 + - 7.5 7.5 XMT LBO L OOPDOWN CONTROL MON RPT RCV MON RPT XMT DSX PREEQ SIGNAL REGEN L OS ALM LIGHTWAVE MUL TIPLEXER S3-1 DISABLE NETWORK SIGNAL DETECTOR NET LOS L OOPBACK COD.
Section 319–29E–202 6 S3 12 S4 DISABLE A I S S1 PWR 7.5 7.5 1 2 O N LP SC S2 LO S ALM R C V X M T R P T M O N R P T M O N WESCOM PWRG T1 NIU 3192-9E 91-31929E 0.6V ISS. 2 FA ESF NET LO S LB CI LO S MLB Figure 6. 3192–9E Front Panel Features and Options Location T able 2.
Section 319-29E-202 7 3.1 Signal T ransmission Paths In the idle (Looped down) mode, the signal from the network is coupled to the unit and routed through the trans- mit pad circuit. Switch S4 mounted on the circuit pack is used to adjust the transmit pad which consists of two cascaded 7.
Section 319–29E–202 8 3.5 T ransmit And Receive Signal Detectors The 3192–9E provides Monitoring Signal Detectors on the transmission paths. These detectors provide a mainte- nance aid for installation and troubleshooting.
Section 319-29E-202 9 4. INSPECTION Inspect the equipment thoroughly upon delivery . If the equipment has been damaged in transit, immediately re- port the extent of damage to the transportation company . Wescom equipment is identified by a model and issue number imprinted on the front panel or located elsewhere on the equipment.
Section 319–29E–202 10 6.2 S2 — Front Panel MLB Push Button S2 is a recessed, front-panel push-button switch used to manually activate or deactivate loopback. Momentarily depress the MLB (Manual Loopback) push-button switch to activate or deactivate a loopback condition.
Section 319-29E-202 11 Step Action Action 8. Momentarily operate the 3192–9E front panel MLB pushbutton switch. The 3192–9E front panel LB LED should light indi- cating that the unit is in Loopback and the TBERD-209 should be receiving the looped back QRSS pattern.
Section 319–29E–202 12 8. TECHNICAL ASSIST ANCE 8.1 T echnical Assistance — U.S. If technical assistance is required, contact Charles Industries’ T echnical Services Center at: 847–806–8500 847–806–8556 (F AX) 800–607–8500 techserv@charlesindustries.
Section 319-29E-202 13 2. Include the following information: – Company name and address – Contact name and phone number – Inventory of equipment being shipped – Particulars as to the nature of the failure – Return shipping address 3.
Section 319–29E–202 14 (c) ESF DA T A LINK: The bit-oriented command and response message 0 001001 0 1 1111111 for 16 milli- seconds to loop up. The bit-oriented command and response message 0 010010 0 1 1111111 for 16 milliseconds to loop down. (d) LOOPBACK TIMEOUT : 20 Minutes 10.
デバイスCharles 31929Eの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Charles 31929Eをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCharles 31929Eの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Charles 31929Eの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Charles 31929Eで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Charles 31929Eを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCharles 31929Eの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Charles 31929Eに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCharles 31929Eデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。