Operating and Installation Instructions CHARNWOOD Country 8 MkII and Country 12 MkII Flat Top, Low Canopy & High Canopy Multifuel Roomheaters Bishops Way, Newport, Isle of Wight, PO30 5WS, U.K. Tel: (01983) 537799 Fax: (01983) 537788 E-Mail: charnwood@ajwells.
Contents Operating Instructions Fuels ................................................................... 3 Door Operation ................................................... 3 Multifuel Grate ................................................... 3 Lighting .
Before lighting the stove check with the installer that the work and checks described in the Installation Instructions have been carried out correctly and that the chimney has been swept, is sound and free from any obstructions. FUELS The following fuels may be burnt on this stove.
position by moving the tool up until the handle is in the 1 o'clock position. The grate is put into the wood position by moving the tool down until the handle is in the 5 o'clock position. To riddle the appliance when burning solid fuels the tool should be moved between the 1 o'clock and 3 o'clock positions several times.
that it begins to block the passage of air into the firebox at the side of the grate. When this is the case do not remove all of the ash using the riddling mechanism but keep a layer about half an inch thick as this enables the wood to burn more effectively.
sweep the chimney through the appliance. First remove the side fire plates, front firebars and the throat plate. Then sweep the chimney ensuring that soot is removed from all horizontal surfaces after sweeping.
HEALTH AND SAFETY PRECAUTIONS Please take care when installing the stove that the requirements of the Health and Safety at Work Act 1974 are met. Some types of fire cement are caustic and should not be allowed to come into contact with the skin. In case of contact wash with plenty of water.
The hot water system should be a gravity circuit and must be correctly vented as shown in Fig. 4. The steel boiler together with a double feed indirect hot water storage cylinder to BS:1566 part 1 sho.
chimney may be swept through the appliance. Horizontal lengths of flue must be kept to a minimum and should not be more than 150mm (6 inches) long. The sealing face of the flue collar should be coated with fire cement before fixing to the body of the stove using the two screws provided.
Ø154 Ø154 71 299 110 46 Ø154 71 299 110 71 299 110 Country 8 HC (High Canopy) Country 8 LC (Low Canopy) Country 8 FT (Flat Top) 552 508 381 1012 526 526 526 381 752 552 513 322 513 381 513 513 322 .
Country 12 MkII Dimensions (All dimensions are in mm) 180 210 180 210 180 210 655 1098 320 462 386 518 1158 584 106 45 655 793 320 Ø154 462 386 518 853 584 125 489 45 658 595 320 Ø154 462 386 518 71.
デバイスCharnwood Country 12 Mk2の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Charnwood Country 12 Mk2をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCharnwood Country 12 Mk2の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Charnwood Country 12 Mk2の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Charnwood Country 12 Mk2で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Charnwood Country 12 Mk2を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCharnwood Country 12 Mk2の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Charnwood Country 12 Mk2に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCharnwood Country 12 Mk2デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。