1/2 HP SUBMERSIBLE PUMP (TRASH W A TER TYPE) ASSEMBL Y AND OPERA TING INSTR UCTIONS 3491 Mission Oaks Blvd., Camarillo , CA 93011 Visit our W eb site at: http://www .harborfreight.com Copyright © 2005 by Harbor F reight T ools ® . All rights reser ved.
PR ODUCT SPECIFICA TIONS SA VE THIS MANU AL Y ou will need this manual f or the saf ety warnings and precautions, assembly , operating, inspection, maintenance and cleaning procedures, parts list and assembly diagram. K eep y our inv oice with this manual.
3. Keep bystanders, children, and visitors away while operating the Sump Pump. Distractions can cause you to lose control. ELECTRICAL SAFETY 1. Grounded tools must be plugged into a GFCI (Ground Fault Circuit Interrupter) outlet properly installed and grounded in accordance with all codes and ordinances.
3. A v oid accidental starting. Be sure the circuit suppl ying electrical power is off before plugging in. Plugging in a Sump Pump with the electrical circuit on invites accidents. 4. Do not overreach. Keep proper footing and balance at all times. Proper footing and balance enables better control of the Sump Pump in unexpected situations.
SER VICE 1. Sump Pump service must be performed only by qualified repair personnel. Service or maintenance performed by unqualified personnel could result in a risk of injur y . 2. When servicing the Sump Pump, use only identical replacement parts. Follo w instructions in the “Inspection, Maintenance , And Cleaning” section of this manual.
SKU 92481 For technical questions, please call 1-800-444-3353. P A GE 6 V ~ A no xxxx/min. No Load Revolutions per Minute (RPM) Amperes V olts Alternating Current Underwriters Laboratories, Inc. Canadian Standards Association Double Insulated SYMBOLOGY FIGURE B FIGURE A 3-PRONG PLUG 120 V OL T , GROUNDED, ELECTRICAL OUTLET SPECIFIC SAFETY RULES 1.
SKU 92481 For technical questions, please call 1-800-444-3353. P A GE 7 wear nonskid rubber boots when water is on the floor and you must unplug the Sump Pump . Ne v er allo w the Motor to get wet. Make sure the electrical pow er source is a separately fused, grounded, 3-wire type GFCI outlet of 15 AMP capacity .
SKU 92481 For technical questions, please call 1-800-444-3353. P A GE 8 10. In cold weather , when the Sump Pump is not in use , protect the interior of the Pump from freezing by draining the liquid and pumping a permanent type automobile antifreeze containing a rust inhibitor through the system.
SKU 92481 For technical questions, please call 1-800-444-3353. P AGE 9 6. Set the Sump Pump in place, using the accessory Rope (41). Do not raise or lower the Sump Pump by its Power Cord or by its Discharge Hose.
SKU 92481 For technical questions, please call 1-800-444-3353. P A GE 10 9 . The Sump Pump will now star t and run continuously until electrical power to the Pump is shut off . 10. When shutting off power to the Sump Pump, always shut off the electrical power to the GFCI outlet fir st.
SKU 92481 For technical questions, please call 1-800-444-3353. P A GE 11 4. Pump Motor runs, but deliver s small amount of water . A. V er tical lift is approaching Sump Pump’ s maximum lift capability . Maximum lift capability is 36 feet. Reduce height of vertical lift.
SKU 92481 For technical questions, please call 1-800-444-3353. P AGE 12 with water is recommended. Be sure to flush the system with a neutralizing liquid prior to reuse of the unit. 7. Every two year s: Change the oil in the Sump Pump . The Pump holds approximately 4-3/4 ounces of oil.
P ARTS LIST SKU 92481 For technical questions, please call 1-800-444-3353. P A GE 13 NOTE: Some parts are listed and shown f or illustration purposes only , and are not available individually as replacement parts. Part # Description Qt y . Part # Description Qt y .
ASSEMBL Y DIA GRAM SKU 92481 For technical questions, please call 1-800-444-3353. P AGE 14 NOTE: Some parts are listed and shown f or illustration purposes only , and are not available individually as replacement parts.
デバイスChicago Electric 92481の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Chicago Electric 92481をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはChicago Electric 92481の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Chicago Electric 92481の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Chicago Electric 92481で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Chicago Electric 92481を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はChicago Electric 92481の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Chicago Electric 92481に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちChicago Electric 92481デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。