CissellメーカーL36URS36Gの使用説明書/サービス説明書
ページ先へ移動 of 37
Page 1 INST ALLA TION/OPERA TION MANUAL 75 Lb. Laundry Dryer MODELS GAS STEAM ELECTRIC L36USS36G L36URD36G L36URS36S L36URS36E L36USD36G L36URS36G L36URD36S L36URD36E MAN354 9/98 D0561 THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER. MANUFACTURING COMPANY CISSELL MANUFACTURING COMPANY HEADQUARTERS PHONE: (502) 587-1292 831 SOUTH FIRST ST.
Page 2 IMPORTANT NOTICES—PLEASE READ For optimum efficiency and safety, we recommend that you read the Manual before operating the equipment. Store this manual in a file or binder and keep for future reference.
Page 3 WARNING: To avoid fire hazard, do not dry articles containing foam rubber or similar texture materials. Do not put into this dryer flammable items such as baby bed mattresses, throw rugs,undergarments (brassieres, etc.) and other items which use rubber as padding or backing.
Page 4 CISSELL DRYER WARRANTY The Cissell Manufacturing Company (Cissell) warrants all new equipment (and the original parts thereof) to be free from defects in material or workmanship for a period of two (2) years from the date of sale thereof to an original purchaser for use, except as hereinafter provided.
Page 5 PAGE Model Numbers & Company Address ............................................................................................. 1 Important Notices .........................................................................................
Page 6 SYMBOLS The following symbols are used in this manual and/or on the machine. The numbers between () refer to the numbers on the machine surveys.
Page 7 SYMBOLS Symbol Description Part/Measurement rotation in two directions rotation dans les deux sens Drehbewigung in zwei Richtungen movimiento rotativo en los dos sentidos End of Cycle caution a.
Page 8 Unpacking/General Installation (All Dryers) Upon arrival of the equipment, any damage in shipment should be reported to the carrier immediately. Upon locating permanent location of a unit, care should be taken in movement and placement of equipment.
Page 9 75 lb. “UR” Dryer Outline Dimensions (Illustration).
Page 10 75 lb. “US” Dryer Outline Dimensions (Illustration) All dimensions given in inches ± 1/4”.
Page 11 Specifications Basket Load Capacity ............................. 75 lbs. (34.0 kg) dryweight Floor Space ............................................. 75 ” (191 cm) H x 38” (96 cm) W x 51” (130 cm) Deep Basket Size .....................
Page 12 Specifications STEAM HEATED MODEL ENERGY SAVER GAS MODEL Operating Steam Pressure ............................ 15 PSIG (low pressure) 100 PSIG (high pressure) Supply Connection to Solenoid ................... 3/4” (1.91 cm) Return Connection .
Page 13 Motor List DOUBLE MOTOR MODELS Motor No. Voltage H z . Phase Basket/Fan H P Amps R P M MTR203 115/200/230 6 0 1 B 1 10.4/5.2 1725 MTR212 200/230/460 6 0 3 B 1 3.8/1.9 1725 MTR206 110/220 5 0 1 B 1 12/6 1425 MTR104 240/415 5 0 3 B 1 3.1/1.8 1425 MTR104 220/380 5 0 3 B 3/4 2.
Page 14 General Information & Grounding Instructions The Cissell Dryer is so designed that when an operator opens the dryer door, the basket and exhaust fan stops. You can expect fast drying from a Cissell Laundry Dryer. Hot, dry air is properly and effectively moved through the basket and exhausted through a lint trap to the atmosphere.
Page 15 Grounding Instructions (Illustration).
Page 16 Piping Recommendations 1. Trap each dryer individually. Always keep the trap clean and in good working condition. 2. When dryer is on the end of a line of equipment, extend header at least 4 feet beyond dryer. Install globe valve, union, check valve and by-pass trap at end of line.
Page 17 Gas Piping Check gas rating plate for type of gas to equip the dryer. Check for altitude elevation of the dryer. Check utility for proper installation of gas supply line and gas pressure. NATURAL GAS ONLY Check the gas pressure inlet supply to dryer, 11” W.
Page 18 Gas Piping Installation (Illustration) The dryer and it’s individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 PSIG.
Page 19 The size of the gas service pipe is dependant upon many variables, such as tees, lengths, etc. Specific pipe size should be obtained from the gas supplier. Refer to the “Gas Pipe Size” chart in this manual for general gas pipe size information.
Page 20 Gas Pipe Size Chart TOTAL BTU/HR (for LP Gas correct total BTU/HR below by multiplying by .6) TOTAL KCAL HOUR GAS PIPE SIZE FOR 1000 BTU (250 KCAL) NATURAL GAS AT 7” (17.8 CM) W.C. PRESSURE In figuring total length of pipe, make allowance for tees and elbows.
Page 21 Steam Piping Installation Instructions 1. Set and anchor dryer in position. Machine should be level to assure proper steam circulation. 2. To prevent condensate draining from headers to dryer, piping should have a minimum 12” above respective header.
Page 22 Steam Piping Installation (Illustration).
Page 23 Dryer Installation With Multiple Exhaust For Exhaust Duct less than 14 feet and 2 elbows equivalent and less than 0.3 inches static pressure. DR YER EXHAUSTS Area of section “A-A” must be equal to the sum of dryer exhaust pipes entering multiple exhaust pipe.
Page 24 Dryer Installation with Multiple Exhaust For Exhaust Duct more than 14 feet and 2 elbows equivalent and more than 0.3 inches static pressure. (See illustration on next page.) 1. Make-up air from outside building may enter enclosure from top or side walls.
Page 25 Dryer Installation With Separate Exhaust (Preferred) For ductwork less than 14 feet and 2 elbows equivalent and less than 0.3 inches static pressure: NEVER exhaust the dryer into a chimney. NEVER install wire mesh screen over the exhaust or make-up air area.
Page 26 Nothing is more important than air flow for the proper operation of a clothes dryer. A dryer is a pump which draws make-up air from the out-of-doors, through the heater, through the clothes and then forces the air through the exhaust duct back to the out-of-doors.
Page 27 Rules for Safe Operation of Dryer 1. Be sure your dryer is installed properly in accordance with the recommended instructions. 2. CAUTION Be safe— shut main electrical power supply and gas supply off externally before attempting service.
Page 28 Operating Instructions - Two Timer Model (Illustration).
Page 29 Operating Instructions - Two Timer Model OPERATING INSTRUCTIONS - TWO TIMER MODEL Step 1. After loading the dryer with water washed clothes, close the loading door. Step 2. Turn the 60 minute drying (heat) timer to the desired time. The drying cycle light will be on.
Page 30 Automatic Computerized Drying Control DESCRIPTION The Automatic Computer Drying Control is used to manage the drying and cooling cycles of one clothes dryer . The operator has the flexibility to select either automatic or timed drying and either automatic or timed cooling.
Page 31 Automatic Computerized Drying Control LED DISPLA Y MESSAGES Display Condition “__0” Normal display between loads. Dryer is waiting for the next load. “012” Normal display during drying/ cooling cycle. Display shows “time used” when in automatic and “time remaining” when in timed mode.
Page 32 Automatic Computerized Drying Control OPERATION OF CONTROL PANEL (See drawing on page 33) 1. ON Turn the control on. If dryer is not used for 30 minutes, the power will turn off. Press “on” for power. 2. OFF/STOP Turns the control off or stops the dryer during a cycle.
Page 33 Automatic Computerized Drying Control OPERATION OF CONTROL PANEL (continued) (See drawing on page 33) 8. DRYING Pressing this button changes the selection of automatic or timed drying, indicated by a light. 9. COOLING Pressing this button changes the selection of automatic or timed cooling, indicated by a light.
Page 34 Automatic Computerized Drying Control Panel (Illustration).
Page 35 Automatic Computerized Drying Control OPTIONS SWITCH SET #1 Switch ON OFF #8 F/C Deg F Deg C #7 SFTY-EN Enabled Disabled #6 6-Add + 6 Min. 0 #5 Repeat S/E Start E nd #4 2 Deg. + 2 Deg. 0 #3 5 Deg. + 5 Deg. 0 #2 10 Deg. + 10 Deg. 0 #1 20 Deg. + 20 Deg.
Page 36 Automatic Computerized Drying Control OPTION SWITCH SET #2 These switches have no function. THERMISTOR CALIBRATION To verify the calibration of the thermistor circuit, proceed as follows: 1. Disconnect the thermistor leads going to the circuit board.
Page 37 Automatic Computerized Drying Control Board (Illustration).
デバイスCissell L36URS36Gの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Cissell L36URS36Gをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCissell L36URS36Gの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Cissell L36URS36Gの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Cissell L36URS36Gで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Cissell L36URS36Gを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCissell L36URS36Gの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Cissell L36URS36Gに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCissell L36URS36Gデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。