Cob alt Digital In c. 9341 Analog Audio to AES Converter Owner’s Manual 9341-OM Version: 1.0.
Page 2 of 22 9341 Owner’s Manual • • • • (V 1.0) 9341 • • • • A ES A udio Delay Owner’s Manual • Cobalt Part Number: 9341-OM • Documen t Version: 1.
9341 User Manual • • • • (V 1.0) Page 3 of 22 Important Regulatory and Safety Notices Before usin g this produ ct and any associated equipmen t, refer to the “ I mportan t Safety Instructions” listed bel ow s o as to avoi d personn el injury and to prevent produ ct dam age.
Page 4 of 22 9341 Owner’s Manual • • • • (V 1.0) Environmental Information The equipm ent that you purchased required the extraction and use of natural resources for its production. It may contain ha zardous substances t hat could impact health and the env ironment.
9341 User Manual • • • • (V 1.0) Page 5 of 22 Contents Introduction 6 In This Ch apter ................................................................................................................ ...........6 A Word of Thanks..............
Page 6 of 22 9341 Owner’s Manual • • • • (V 1.0) Introduction In Thi s Chapter This chapter includes the follow ing sections: • A Wor d of T hanks • Overview • Functio nal Bl ock D iagra m • Features • Documenta tion T er ms A Word of Thanks Congra tulati ons o n choo sing the o penG ear 9341 Analog Au dio to AES Converter .
9341 User Manual • • • • (V 1.0) Page 7 of 22 Supported A udio Formats Discrete AES A udio Output The 9341 can em it 8 chan nels (4 pairs) of discrete A ES audio on 75 ohm BNC connecti ons. The out put clock rate of each pair is precisely locked, and deriv ed from the inpu t AES, or the f rame ref erence.
Page 8 of 22 9341 Owner’s Manual • • • • (V 1.0) Functional Block Diagram This secti on describes the basi c operation of you r 9341 product. Figure 1. Simplif ied Bloc k Diagram of 9341 Func tions Differen tial analog au dio signals are received on th e input phoen ix conn ectors.
9341 User Manual • • • • (V 1.0) Page 9 of 22 Installation and Setup In Thi s Chapter This chapter includes the follow ing sections: • Static Discharge • Unpackin g • Rear Module Install.
Page 10 of 22 9341 Owner’s Manual • • • • (V 1.0) Rear Module Installa tion (Optional) If y o u are in stalli ng t he card in a 8310- C-BNC or 8310-BN C fram e (one wi th a 100 BNC rear modu le installed across the entire back plan e), skip this section.
9341 User Manual • • • • (V 1.0) Page 11 of 22 Rear Modules A v ailable for 9341 Figu re 3. BNC Des ignat ions f or the Ca rd Rear Modules availabl e for the 9341.
Page 12 of 22 9341 Owner’s Manual • • • • (V 1.0) Board Installation Use the follow ing steps to install the card in the openGear TM 8310 fram e: 1. Refer to the Ow ner’s Manu al of the openGear TM 8310 fram e to ensure that th e fram e is properly installed according to instru ctions.
9341 User Manual • • • • (V 1.0) Page 13 of 22 Card Control and Status Card Status The card indicates the status of the input sig nal w ith the f our blue LEDs labled with the different supporte d form ats (1080, 720, 625, 525), th ese LE Ds correspon d to AES Inputs 1-4.
Page 14 of 22 9341 Owner’s Manual • • • • (V 1.0) Tone Frequency This sets the f requency of the test tone f or each of the f o ur tone gen erators. Each of the four ton e generators TG1 – T G4 can be set to a dif ferent f requency, and are av ailable as audio sources for the embedded or A ES audio output s.
9341 User Manual • • • • (V 1.0) Page 15 of 22 Informati on Submenu Menu Structure Param eter Type Info +POW Positive Watts Consumed -POW Negative Watts Consum ed SWR# Softw are Release Number SWB# Software Build Number Positive Watts Consumed A read only indication of pow er consum ed by th e card from the fram es +12V rail.
Page 16 of 22 9341 Owner’s Manual • • • • (V 1.0) Remote Control In Thi s Chapter This section provides a detailed explanation on usin g rem ote control functions w ith your card. DashBoard Co ntrol System Softw are The DashBoard Control Sy stem enables you to m onitor and control openGear TM f rames and controller cards from a computer.
9341 User Manual • • • • (V 1.0) Page 17 of 22 Menu Item Format Description DARS Locked / Unlock ed Status indicator f or DARS audio in put Refe rence Stan dard ############ Detected standard of selected reference. Settings Saved / Unsaved This sho ws w het her the curr ent sett ings have b een saved to a preset.
Page 18 of 22 9341 Owner’s Manual • • • • (V 1.0) Technical Specifications Num ber of Inputs 8 Balanced A nalog Au dio Connector Phoeni x 3- pin Sampling Rate 48KHz (free run or locked to th.
9341 User Manual • • • • (V 1.0) Page 19 of 22 Service Information In Thi s Chapter This chapter includes the follow ing sections: • Tro ubleshooting Checklist • Warranty an d Repair Policy Troubleshooting Checklist Routine m aintenance to this openGear product is not requ ired.
Page 20 of 22 9341 Owner’s Manual • • • • (V 1.0) Warranty and Repair Polic y The openGear card is warran ted to be free of any defect w ith respect to performan ce, quality, reliability, and w orkmansh ip for a period of FIVE (5) years from the date of shipm ent from our factory .
9341 User Manual • • • • (V 1.0) Page 21 of 22 Ordering Information 9341 and Related Products Your 9341 A nalog Aud io to AES C onverter is a part of the openG ear fam ily of produ cts.
Page 22 of 22 9341 Owner’s Manual • • • • (V 1.0) Contact Us Contact Cobalt Digita l Inc. General Business Office and Technical Support 217.344.1243 PHONE Fax 217.344.1245 General Information In fo@cobaltdigital.com E-MA IL Sales Information Sales@cobaltdig ital.
デバイスCobalt Networks 9341の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Cobalt Networks 9341をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCobalt Networks 9341の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Cobalt Networks 9341の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Cobalt Networks 9341で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Cobalt Networks 9341を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCobalt Networks 9341の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Cobalt Networks 9341に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCobalt Networks 9341デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。