ColdTechメーカーCFD-1Fの使用説明書/サービス説明書
ページ先へ移動 of 12
COMMERCIAL REFRIGERA T OR AND FREEZER OWNER'S MANUAL Models: CFD-1R, CFD-1F , CFD-2R, CFD-2F , CFD-3R, CFD-3F This manual contains important information regarding your new ColdT ech unit. Please read the manual thoroughly prior to equipment set-up, operation and maintenance.
T ABLE OF CONTENTS Page 2...............................................................ColdT ech Limited W arranty Page 3.........................................................................................Installation Page 5.....................
INST ALLA TION IMPORT ANT!!! PLEASE READ BEFORE INST ALLA TION 1) If the unit has recently been transported please let unit stand still for a minimum of 24 hours before plugging it in. 2) Make sure that the unit drops down to desired temperature before loading the unit with product.
SHELF BRACKET INST ALLA TION Make sure to follow diagrams to properly install shelf brackets!!! (picture of interior pilasters, right side) (picture of interior pilasters, left side) 1) Attach.
SAFETY / W ARNING Please pay close attention the the safety notices in this section. Disregarding these notices may lead to serious injury and/or damage to the unit. KEY 1) T o minimize shock and fire hazards, be sure not to overload outlet. Please designate one outlet for your unit.
REGULAR MAINTENANCE CLEANING THE CONDENSER COIL For efficient operation, it is important that the condenser surface be kept free of dust, dirt, and lint. ColdT ech recommends cleaning the condenser coil and fins at least once per month. Clean with a commercial condenser coil cleaner , available from any kitchen equipment retailer .
SEE P A GE 9 -7-.
-8-.
ColdT ech® Refrigerator Settings T emperature set to 37 F Parameter Function Set Range Default E1 Lower Setpoint Limit -40 F ~ set temp 36 F E2 Higher Setpoint Limit set temp ~ 120 F 45 F E3 Hysteresis, temp.
ColdT ech® Freezer Settings T emperature set to -4 F Parameter Function Set Range Default E1 Lower Setpoint Limit -40 F ~ set temp -10 F E2 Higher Setpoint Limit set temp ~ 120 F 20 F E3 Hysteresis, temp variance 1 ~ 18 F 10 F E4 Comp.
SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Compressor not running. Fuse blown or circuit breaker tripped. Replace fuse or reset circuit b r e a k e r . Power cord unplugged. Plug in power cord.
T he New S ymbol of Innov ation™ MEMO RET AIN THIS MANUAL FOR FUTURE REFERENCE Please read the entire manual carefully before installation and operation. If certain recommended procedures are not followed, warranty claims will be denied. Notice: ColdT ech reserves the right to make changes in design and specifications without prior notice.
デバイスColdTech CFD-1Fの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
ColdTech CFD-1Fをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはColdTech CFD-1Fの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。ColdTech CFD-1Fの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。ColdTech CFD-1Fで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
ColdTech CFD-1Fを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はColdTech CFD-1Fの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、ColdTech CFD-1Fに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちColdTech CFD-1Fデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。