292043-UIM-B-0707 SINGLE PIECE AIR HANDLERS MODELS: F*FP INSTALLATION MANUAL ISO 9001 Certified Quality Management System SAFETY This is a safety alert symbol . When you see this symbol on labels or in manuals, be alert to the potential for personal injury .
292043-UIM-B-0707 2 Unitary Products Group SPECIFIC SAFETY RULES AND PRE CA U TIONS 1. Install this air handler only in a location and position as specified in SECTION I of these instructions. 2. Always install the air handler to operate within the air handler ’s intended maximum outlet air t emperature.
292043-UIM-B-0707 Unitary Products Group 3 6. When an evaporator coil is instal led in an attic or above a finished ceiling, an auxiliary dr ain pan should be provided under the coil as is specified by most local building codes. 7. Proper electrical supply must be available.
292043-UIM-B-0707 4 Unitary Products Group FIGURE 3: Filter Access & Drain Pan Conversion / Coil Baffle FIL TER 4B - SIDE VIEW "S" BRACKET MUST BE USED TO F ASTEN DUCT WORK T O FRONT OF .
292043-UIM-B-0707 Unitary Products Group 5 DUCT CONNECTIONS NOTE: The electric heat accessory s hould be installed before the sup- ply air duct is attached to the suppl y air openings. Refer to the electric heater kit instructions for proper installation.
292043-UIM-B-0707 6 Unitary Products Group • If the suction line is 3/4" diamet er - position the bulb near the top of the copper tube as show n. If the tube is 7/8" diameter - position the bulb near the bottom of the tube. Refer to Figure 7.
292043-UIM-B-0707 Unitary Products Group 7.
292043-UIM-B-0707 8 Unitary Products Group LO W VOL T A GE CONTR OL CONNECTION The 24 volt power supply is provi ded by an int ernally wired low voltage transformer which is standard on all model s. However, if the unit is con - nected to a 208 volt power supply the low voltage transformer must be rewired to the 208 volt tap.
292043-UIM-B-0707 Unitary Products Group 9 TA B L E 3 : Physical and Electrical Data Models F*FP 024 030 036 040 Blower - Diameter x Width 10 x 6 10 x 8 10 x 8 10 x 8 Motor HP 1/4 1/3 1/2 1/3 Nominal RPM 1075 1075 1075 1075 V oltage 208/230 Amps Full Load (208/230) 1.
292043-UIM-B-0707 10 Unitary Products Group * May be 0 (no breaker) or 1 (with breaker). TA B L E 6 : Electrical Data - 1 Ø - 2 08/230-1 -60 1 Models F*FP Heater* Model Max. St atic & Min. CFM T otal Heat 2 KW St aging 3 KW MBH W1 Only W2 Only W1 + W2 St atic T ap 208V 240V 208V 2 40V 208V 240V 2 08V 240V 208V 240V 024 2HK*6500506B 0.
292043-UIM-B-0707 Unitary Products Group 11 * May be 0 (no breaker) or 1 (with breaker). TA B L E 7 : Electrical D a t a - (For Single Source Power Supply) - Copper W ire 1 Ø - 20 8/230-1-60 1 Models F*FP Heater* Model Heater Amps 240V Field W iring Min.
292043-UIM-B-0707 12 Unitary Products Group TA B L E 9 : Electrical Data - 3 Ø - 2 08/230-3 -60 1 Models F*FP Heater 2 Model Max. St atic & Min. CF M T ot al Heat KW St aging 3 KW MBH W1 Only W2 On ly W1 + W2 St atic T ap 208 240 208 240 208 240 208 240 208 240 024 2HK06501025B 0.
292043-UIM-B-0707 Unitary Products Group 13 All F*FP series air handler unit s are UL Listed up to 0.50" w .c. external st atic pressure, including air filter , wet coil, and largest KW size heater . TA B L E 1 1 : Airflow Data for 2 30 V olt - Heat Pump Models 1 1.
292043-UIM-B-0707 14 Unitary Products Group T A BLE 12: Airflow Data 1 for 208 V olt - Heat Pump Models 1. Includes Return Air Filter and Largest Electric Heate r . All F*FP series air handler unit s are UL Listed up to 0.50" w .c. external st atic pressure, including air filter , wet coil, and largest KW size heater .
292043-UIM-B-0707 Unitary Products Group 15 NOTES: 1. “Y” T erm inal on Air Handler Control Bo ard must be connected for full CFM and applications requiring 60 second Blower Off Del ay for SEER enhancement. 2. 1 Optional Dehumidification Humidi stat con tacts open on rise.
Subject to change without notice. Printed in U.S.A. 292043-UIM-B-0707 Copyright © by York International Corp. 2007. All rights reserved. Supersedes: 292043-UIM-A-0507 Unitary 5005 Norman Product Y or.
デバイスColeman F*FPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Coleman F*FPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはColeman F*FPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Coleman F*FPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Coleman F*FPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Coleman F*FPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はColeman F*FPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Coleman F*FPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちColeman F*FPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。