CompaqメーカーDWZZHの使用説明書/サービス説明書
ページ先へ移動 of 34
DWZZH 16-Bit UltraSCSI Hub User’s Guide EK–DWZZH–UG. D01 Compaq Computer Corporation.
Fourth Edition, November 1998 While Compaq Computer Corporation believes the information included in this manual is correct as of the date of publication, it is subject to change without notice.
Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten, in welchen Fällen der Benutzer für entsprechende Gegenmaßnahmen verantwortlich ist. Attention ! Ceci est un produit de Classe A.
.
EK–DWZZH–UG. D01 v Contents Revision Record ……………………………………………………………….. vii About This Guide ………………………………………………………….….. .ix 1 Introducing the DWZZH UltraSCSI Hub 1.
DWZZH 16-Bit UltraSCSI Hub vi EK–DWZZH–UG. D01 Figures (Cont’d) 3–1 Running One SWCC Agent for a Particular Storage Subsystem ............................. 3–3 Tables 1–1 DWZZH Hub Functional Specifications.................................
EK–DWZZH–UG. D01 vii Revision Record The Revisi on Record provides a concise publi cation history of t his guide. It lists t he guide revision levels and release dates, and summarizes the changes. The following revision history lists all revisions of this publication and their effective dates.
DWZZH 16-Bit UltraSCSI Hub viii EK – DWZZH–UG. D01 EK–DWZZH–UG. D01 October 1998 Change Section 2.1, add CAUTION after Section 2.1. Make minor changes to Section 2.3.3; renumber Section 2.3.3 as Section 2.3. Renumber Sections 2.3, 2.4, 2.5, and 2.
EK–DWZZH–UG. D01 ix About This Guide This chapter tells you what this User’s Guide does, identifies the audience, describes the struct ure and contents (chapter- by-chapter) briefly, and tell s you how to get suppor t and services from Compaq.
DWZZH 16–Bit UltraSCSI Hub x EK–DWZZH–UG. D01 Document Structure This guide contains the following chapters: Chapter 1. Introducing the DWZZH UltraSCSI Hub This chapter gives brief functional and physical descriptions of the DWZZH Hub and lists significant product specifications.
About This Guide EK–DWZZH–UG. D01 xi Who to contact in Europe Information and Product Questions , Contact the Compaq Distributor or reseller Installation Support, and Installation: from whom the Storage Solution was purchased. For Warranty Service See the Warranty Card packaged with the product.
.
EK–DWZZH–UG. D01 1–1 1 Introducing the DWZZH UltraSCSI Hub This chapter descr ibes the DWZZH Hub functions and availabl e versions, and list the Hub functional specifications.
DWZZH 16-Bit UltraSCSI Hub 1–2 EK–DWZZH–UG. D01 1.2 Product Descriptions There are two classes of DWZZH Hubs: 3.5" SBB Hubs, and 5.25" SBB Hubs. 1.2.1 DWZZH 3.5" SBB Hubs The DWZZH small UltraSCSI Hub (Figure 1-1) comes in two versions.
Chapter 1. Introducing the DWZZH UltraSCSI Hub EK–DWZZH–UG. D01 1–3 Figure 1–2 DWZZH–21 Front Panel NOTE The si ngle–ended s ymbol wit h the downwar d– point ing di amond in Fi gure 1- 2.
DWZZH 16-Bit UltraSCSI Hub 1–4 EK–DWZZH–UG. D01 1.2.2 DWZZH 5.25" SBB Hubs The DWZZH large UltraSCSI Hub (Figure 1-4) comes in a single version that contains five differential UltraSCSI bus connectors. CAUTION Connect ing a si ngle- ended bus c able t o any differential connector causes the SCSI bus to fail.
Chapter 1. Introducing the DWZZH UltraSCSI Hub EK–DWZZH–UG. D01 1–5 1.3 Product Specifications Table 1-1 lists the functional specifications for the DWZZH Hub. Table 1–1 DWZZH Hub Functional Specifications Feature Specification SCSI ID SCSI Addresses The small UltraSCSI HUB does not use a SCSI ID.
DWZZH 16-Bit UltraSCSI Hub 1–6 EK–DWZZH–UG. D01 Table 1–1 DWZZH Hub Functional Specifications (Cont’d) Feature Specification Cable Fault DIFFSENSE support and port disable on cable fault Gli.
EK–DWZZH–UG. D01 2–1 2 Using the DWZZH UltraSCSI Hub This chapter discusses fair ar bitrat ion of the SCSI bus by t he 5.25" SBB Hub, describes addressing configurations, tells you how to use the large Hub fr ont panel, and gives guidelines for selecting the SCSI cables.
DWZZH 16–Bit UltraSCSI Hub 2–2 EK–DWZZH–UG. D01 removed from the group and at the next arbitration phase, the remaining highest ID will be serviced. This will continue until all of the IDs in the group have been serviced once. All requests from IDs not contained in the register will be “backed off ” using ID 7.
Chapter 2. Using the DWZZH UltraSCSI Hub EK–DWZZH–UG. D01 2–3 Figure 2–1 DWZZH–05 SCSI ID Assignments C o n tro ll e r P o rt S C S I ID 6 -0 Hos t Por t S C S I ID 1 5 Hos t P or t SCS I I D 1 4 Ho s t Po r t SCSI I D 13 Ho st Po r t SCSI I D 12 S HR- 1 0 6 9 2.
DWZZH 16–Bit UltraSCSI Hub 2–4 EK–DWZZH–UG. D01 Figure 2–2 DWZZH–05 SCSI Narrow ID Assignments C o n tro ll e r P o rt S C S I ID 6 -4 Ho st Po r t S C S I ID 3 Ho st P o rt SCS I I D 2 Ho.
Chapter 2. Using the DWZZH UltraSCSI Hub EK–DWZZH–UG. D01 2–5 Figure 2–3 DWZZH–05 SCSI Narrow Addressing Jumper W1 (To enable narrow addressing mode, install a jumper at W1).
DWZZH 16–Bit UltraSCSI Hub 2–6 EK–DWZZH–UG. D01 2.4 Front Panel Figure 2-4 shows the location of the front panel controls and indicators. Figure 2–4 DWZZH–05 Front Panel Busy Power S HR- 1 0 7 0 Fai r D i sabl e NOTE The black part of the s wit ch i n the di agram indicates the position of the switch.
Chapter 2. Using the DWZZH UltraSCSI Hub EK–DWZZH–UG. D01 2–7 2.4.2 Indicators The large Hub has two indicators on the front panel. The green LED indicates that POWER is applied to the Hub, while the yellow LED indicates that the SCSI bus is BUSY.
DWZZH 16–Bit UltraSCSI Hub 2–8 EK–DWZZH–UG. D01 Table 2-1 Combinations of UltraSCSI Hubs and Devices in StorageWorks Shelves Number of Small Hubs (DWZZH–03/–21) Number of Large Hubs (DWZZH.
EK–DWZZH–UG. D01 3–1 3 SWCC and UltraSCSI Hubs This chapter is intended to provide you with import ant inform ation regarding t he use of StorageWor ks Command Console on SCS I buses t hat have an UltraSCSI Hub. While the informat ion provided here is important , it is essential that you have read the SWCC Manual and Release Notes.
DWZZH 16-Bit UltraSCSI HUB 3–2 EK–DWZZH–UG. D01 This type of configuration would prevent systems with different SCSI IDs from accessing disks ‘ belonging to ’ a particular SCSI ID, which promotes data security between servers on a shared SCSI bus; however, it does not prevent SWCC from performing tasks on those disks.
Chapter3. SWCC and UltraSCSI Hubs EK–DWZZH–UG. D01 3-3 Figure 3-1 Running One SWCC Agent for a Particular Storage Subsystem BA 370 Cabine t wi t h HS Z 70 C o nt rollers Host S y st em Host S y st.
.
EK–DWZZH–UG. D01 Glossary–1 Glossary This Glossary includes an alphabetized listing and brief definition of the abbreviations, acronyms, Compaq-specific refer ences, and other technical terms t hat are used in this manual and that may be unfamiliar to the reader.
DWZZH 16–UltraSCSI Hub Glossary–2 EK–DWZZH–UG. D01 host adapter A device that connects the host system I/O bus (for example, a PCI bus) to the storage SCSI bus. A host adapter performs the lower layers of the SCSI protocol and normally operates in the initiator role.
Glossay EK–DWZZH–UG. D01 Glossary–3 SCSI end-bus position The physical location of a controller or a device that contains the SCSI bus termination. SCSI mid-bus position The physical location of a controller or a device that the SCSI bus passes through enroute to the controller or device that contains the SCSI bus termination.
DWZZH 16–UltraSCSI Hub Glossary–4 EK–DWZZH–UG. D01 UltraSCSI An improvement in SCSI technology invented in 1993 by the Compaq Computer Corporation StorageWorks Engineering Group. Subsequently the ANSI SCSI Standards Committee issued standard X3T10 for UltraSCSI.
デバイスCompaq DWZZHの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Compaq DWZZHをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCompaq DWZZHの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Compaq DWZZHの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Compaq DWZZHで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Compaq DWZZHを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCompaq DWZZHの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Compaq DWZZHに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCompaq DWZZHデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。