Connect TechメーカーCTIM-00015の使用説明書/サービス説明書
ページ先へ移動 of 27
BlueStorm Univer sal PCI User Manual Contact Information: Connect Tech Inc. 42 Arrow Road Guelph, Ontario, Canada N1K 1S6 Tel: 519-836-1291 (International) 800-426-8979 (Canada & USA) Fax: 519-836-4878 Email: sales@connecttech.com support@connecttech.
BlueStorm I nstallation Guide, Conne ct Tech Inc. 2 Revision 0.10 Limited Lifetime Warranty Connect Tec h Inc. provides a lifetime warranty for all * Connect Tech Inc. products. Shoul d this product, in Con nect Tech Inc.'s opinion, fail to be in good working order during the warra nty period, Connect Tech Inc.
BlueStorm I nstallation Guide, Conne ct Tech Inc. Revision 0.10 3 Table of Contents Limite d Lifetime Warranty .............................................................................................................................. 2 Copyrig ht Notice.
BlueStorm I nstallation Guide, Conne ct Tech Inc. 4 Revision 0.10 List of Tables Table 1: DB -25 Male Pinouts for B lueStorm/LP (2 Port Co nnector) ........................................................... 13 Table 2: HDB -44 Pinouts for BlueStor m/LP (4 Port Connecto r) .
BlueStorm I nstallation Guide, Conne ct Tech Inc. Revision 0.10 5 Customer Suppo rt Overvie w If you experience dif ficulties after read ing the manual and/or using the product, co ntact the Connect Tec h Inc. reseller from which you purc hased the pro duct.
BlueStorm I nstallation Guide, Conne ct Tech Inc. 6 Revision 0.10 Introduction Connect Tec h Inc. presents BlueStor m /LP/SP/SP Opto and SP RJ-11 . These high-speed multi- port co mmuni catio n adapters are designed for Low Profile (LP) and Standard Profile (SP) PCI compatible computers.
BlueStorm I nstallation Guide, Conne ct Tech Inc. Revision 0.10 7 BlueStorm Insta llation Overvie w There ar e three stages to installing y our B lueStorm card: 1. Hard w are Configuration Interrupts and Me mory selection will be set by the host com puter’s BIOS and o perating system.
BlueStorm I nstallation Guide, Conne ct Tech Inc. 8 Revision 0.10 Multi-drop Slav e Mode In this mode the T xD+/- line driver is enabled only when data is transmitted and RxD+/ - is enabled at all ti m e s. This mode is typically used in multi-dr op 4-wire connection s.
BlueStorm I nstallation Guide, Conne ct Tech Inc. Revision 0.10 9 Figure 1: BlueStorm /LP Jumper Block Locations (2 Po rt Models) Figure 2: BlueStorm /LP Jumper Block Locations (4 Po rt Models) Figure.
BlueStorm I nstallation Guide, Conne ct Tech Inc. 10 Revision 0.10 Figure 4: BlueStorm /SP Jumper Block Locations (8 Port Models) Figure 5: BlueStorm /SP Opto J u m per Block Locations ( 4 Port Models.
BlueStorm I nstallation Guide, Conne ct Tech Inc. Revision 0.10 11 )Figure 6: BlueSto rm/SP RJ-11 (8 Port Model) Note: Refer to Table 8 for port 7 and port 8 pinouts. Jumper Configura tion for BlueStor m Jumper configuratio n options will vary by model.
BlueStorm I nstallation Guide, Conne ct Tech Inc. 12 Revision 0.10 Figure 9 illustrates t he jumper co nfigurations for selecting +5V power or +12 V power.
BlueStorm I nstallation Guide, Conne ct Tech Inc. Revision 0.10 13 the operating s ystem is booted by the curren t driver/software RS-485 mode. T he jumper is used to ensure that a po rt will power-on tri-stated . For example, the RS -485 mode selection i n the Windows control panel will override this jumper setting once a port is opened.
BlueStorm I nstallation Guide, Conne ct Tech Inc. 14 Revision 0.10 19 2 DTR output RXD- input 20 1 DTR output RXD- input 21 NC no connect NC no connect 22 1 RI input CTS+ input 23 2 RI input CTS+ input 24 NC no connect NC no connect 25 2 DCD input RXD+ input Cable CBG002 sends the signals to two DB-9 male connectors.
BlueStorm I nstallation Guide, Conne ct Tech Inc. Revision 0.10 15 38 NC no connect NC no connect 39 3 DSR input CT S- input 40 3 DTR output RXD- input 41 3 RI input CT S+ input 42 4 DSR input CT S- input 43 4 DTR output RXD- input 44 4 RI input CT S+ input Cable CBG003 sends the signals to four DB-9 male connectors.
BlueStorm I nstallation Guide, Conne ct Tech Inc. 16 Revision 0.10 Table 3 : VHDCI-68 Female Pinouts for Bl ueStorm/LP (8 Port Connector) Pin No. Port No.
BlueStorm I nstallation Guide, Conne ct Tech Inc. Revision 0.10 17 Table 3 : VHDCI-68 Female Pinouts for Bl ueStorm/LP (Continued ) Pin No. Port No. RS-232 Signal Signal Direction RS-422/4 85 Signal Signal Direction 47 6 RTS output RTS- output 48 6 DSR input CTS- input 49 6 RXD input T XD+ output 50 6 CTS input RTS+ output 51 5, 6 SG signal gnd.
BlueStorm I nstallation Guide, Conne ct Tech Inc. 18 Revision 0.10 Table 4 : HDB-78 Pinouts for BlueSto rm/SP (8 Port Conne ctor) Pin No. Port No. RS- 232 Signal Signal Direction RS-422/4 8 5 Signal S.
BlueStorm I nstallation Guide, Conne ct Tech Inc. Revision 0.10 19 Table 4 : HDB-78 Pinouts for BlueSto rm/SP (Continued) Pin No. Port No. RS- 232 Signal Signal Direction RS-422/4 8 5 Signal Signal Di.
BlueStorm I nstallation Guide, Conne ct Tech Inc. 20 Revision 0.10 Table 5 : RJ-45 Pinouts for BlueStorm /SP Opto (4 Port Connector) Pin No. RS-232 Signal Direction RS-422/485 Signal Direction 1 N/C no connect RTS (-) o utput 2 N/C input RxD (+) input 3 RTS output RTS (+) output 4 SG signal gnd SR signal ref.
BlueStorm I nstallation Guide, Conne ct Tech Inc. Revision 0.10 21 Table 6 : Pinouts and Control Signals f or DB-9 and DB-2 5 Male Connectors (BlueSto rm/LP and BlueStorm/SP Only) Pin # RS-232 RS-422/.
BlueStorm I nstallation Guide, Conne ct Tech Inc. 22 Revision 0.10 Table 8 : RJ-11 Pinouts for BlueStorm /SP RJ-11 ( Ports 7 and 8 Only) Pin No. RS-232 Direction 1 DCD input 2 DSR input 3 RxD input 4 RTS o utput 5 TxD o utput 6 CTS in put 7 DTR output 8 RI input 9 SG signal gnd .
BlueStorm I nstallation Guide, Conne ct Tech Inc. Revision 0.10 23 Figure 10: BlueSto rm External I/O Box Diagram External I/O Box (part number : IOBG08BLV1) Male DB-9 conne ctors Mounting bracke t VHDCI-68 conne ctor Note: View VHDCI-68 connector pinouts in Table 3 .
BlueStorm I nstallation Guide, Conne ct Tech Inc. 24 Revision 0.10 Figure 11: RS-42 2/485 Wiring Dia grams (BlueStorm/LP and BlueStorm/SP Only) RTS + RTS - CTS + CTS - TxD + TxD - RxD + RxD - RxD + Tx.
BlueStorm I nstallation Guide, Conne ct Tech Inc. Revision 0.10 25 Hardware Instal lation Turn the po w er o ff to your computer a nd open it to expo se the expansion slots (cons ult your system’s docu m e ntation for more infor mation about this proce dure).
BlueStorm I nstallation Guide, Conne ct Tech Inc. 26 Revision 0.10 UARTs BlueStorm/LP (2 por t m od els) ■ 17D152 dual UART with 64 byte TxD/RxD FIFO b uffers BlueStor m/LP (4 port m ode ls) ■ 17D.
BlueStorm I nstallation Guide, Conne ct Tech Inc. Revision 0.10 27 Certification Connect Tec h Inc. declares that the pr oduct(s) covered b y t he contents of this manual have been tested and found co.
デバイスConnect Tech CTIM-00015の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Connect Tech CTIM-00015をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはConnect Tech CTIM-00015の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Connect Tech CTIM-00015の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Connect Tech CTIM-00015で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Connect Tech CTIM-00015を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はConnect Tech CTIM-00015の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Connect Tech CTIM-00015に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちConnect Tech CTIM-00015デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。