Blue Heat/ Net Sync User Manual Ethernet- to -Serial Synchronous Communications Connect Tech Inc. 42 Arrow Road Guelph, Ontario N1K 1S6 Tel: 519-836-1291 Toll: 800-426-8979 (North America only) Fax: 519-836-4878 Email: sales@connecttech.com support@connecttech.
Connect Tech Blue Heat/Net Sync User Manu al 2 R e v is i on 0 . 03 Limited Lifetime Warranty Connect Tech Inc. p rovides a Lifetime W arranty for all Connect T ech Inc. products. Should this product, in Connec t Tech Inc.'s opinion, fail to be in good working order during the warranty period, Connect T ech Inc.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 3 Customer Supp ort Overv iew If you experience difficulties a fter reading the manual a nd/or using the product, co ntact the Connect Tech reseller from which you pu rchased the prod uct. In most cases the reseller can help you with product installatio n and difficulties.
Connect Tech Blue Heat/Net Sync User Manu al 4 R e v i s i on 0 . 03 Certification Stat ements Preliminary: Testing is still pending. Class A Computing Dev ice Connect Tech Inc.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 5 Table of Conten ts Limited Lifetime Warranty ................................................................................................................... 2 Copyright Notice ..........
Connect Tech Blue Heat/Net Sync User Manu al 6 R e v i s i on 0 . 03 info .............................................................................................. 27 net ...........................................................................
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 7 DHCP Setup .................................................................................................. 69 Using SCM ...................................................................
Connect Tech Blue Heat/Net Sync User Manu al 8 R e v i s i on 0 . 03 List of Tables Table 1: Blu eHeat/Net Sync Power Connections an d Current Specification s .............................. 16 Table 2: Con nector Properties ...........................
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 9 Introduction Connect Tech‟s Bl ue Heat/Net Sync allo ws remote access to synchronous/as ynchronous ser ial devices via an Ethernet LAN or the Internet.
Connect Tech Blue Heat/Net Sync User Manu al 10 Re vi si on 0. 03 Understand ing Virtual COM P orts In a typical serial port setup, t he app lication communicates directly with the connected serial port hardware.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 11 Hardware Instal l ation Connectin g the Blue Heat/Net Sync to Y our Network: Before you begin, take a minute to ensure that your package i.
Connect Tech Blue Heat/Net Sync User Manu al 12 Re vi si on 0. 03 Serial Port LEDs The serial po rts LEDs indicate serial activity for each port. • A flashing LED i ndicates that the port in q uestion is receiving or transmitting data. Connectin g Serial Devices V.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 13 RS - 422/ V.11 Con nections The following are basic con nections that can be acco mplished when the I/O levels are in V.11 (RS - 422) mode. V.11 mode signaling can be enabled w ith EIA -530 , RS-449 or X.
Connect Tech Blue Heat/Net Sync User Manu al 14 Re vi si on 0. 03 Loopb ack Connectors Loopback connectors are u seful for performin g diagnostics. T he following figure illustrates the recommended p inouts for creating loop back connectors for Blue Heat/Net Sync .
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 15 Connectin g Power The Blue Heat/Net S ync uses either a sta ndard DC po w er jack or a Phoenix locking screw terminal connector for power input. The Blue Heat/Net Sync can be safely connected o r disconnected at an y time.
Connect Tech Blue Heat/Net Sync User Manu al 16 Re vi si on 0. 03 Table 1: BlueH eat/Net Sync Power Connections and Cur rent Specifications BlueHeat/Net Description Connector plug type Connector Polar.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 17 Activating the Spe cial Operations Mod e and Default Settings Blue Heat/Net Sync includes a push butto n on the rear o f the unit beside the DC po wer connector.
Connect Tech Blue Heat/Net Sync User Manu al 18 Re vi si on 0. 03 Table 3 : Available Special Operations Special Operation Number of presses (a nd binary representation) Usage Force port scanning to first two ports ( Scanning run s until current scannin g delay setting times out.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 19 In the above example, a rapidly flashing CPU LED during the boot up process signifies the B lue Heat/Net Sync has e xperienced an er ror. Port LEDs 1 through 4 si gnify whic h error has occurred.
Connect Tech Blue Heat/Net Sync User Manu al 20 Re vi si on 0. 03 5. Cannot ob tain an operating s ystem image (uClinux) to r un. This will occur wh en any of the enabled boot sources ( flash or BOOTP/TFT P or TFTP) fail to o btain a valid compressed operating system i mage to run.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 21 15. Mismatched CDS versio n number uClinux checks the CDS vers ion number against its expected CD S version number.
Connect Tech Blue Heat/Net Sync User Manu al 22 Re vi si on 0. 03 Set the IP Add ress U sing the Web Configuration Manager NOTE : If you use the W indows Configuration Manager and use Auto Discov er to locate your Blue Heat/Net Sync on the network , y ou c an right-click and launch the W eb Configuration Manager fr om there.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 23 Blue Heat/Net Sy nc Configu ration The Blue Heat/Net S ync comprises se veral software co m ponents, each o f which manages various functions o f the Blue Heat/Net S ync. The following is a brea kdown of these components.
Connect Tech Blue Heat/Net Sync User Manu al 24 Re vi si on 0. 03 program on a PC). Configuration Data Space (CDS) This is the area, in non -volatile ( flash) memory, which stores the con figuration parameters.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 25 SCM (Serial Co nfiguration Manager) Description The Serial Configuration Ma nager is one of the app lications you can use to access the Configuration Data Sp ace (CDS) setti ngs of the Blue Heat/Net Sync.
Connect Tech Blue Heat/Net Sync User Manu al 26 Re vi si on 0. 03 save Sa ve setting c hanges to non-vo latile flash storage update Download a new oper ating system via TFTP and flash, (uClinux) and loader/SCM image.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 27 password= This sets the password phrase, which is used to gain access to the SCM and WCM modes of configuri ng the Blue H eat/Net.
Connect Tech Blue Heat/Net Sync User Manu al 28 Re vi si on 0. 03 [my_ip= | mip =] [s erver_ip= | sip=] [gateway_ip= | gip=] [subnetm ask= | snm=] [broadcast_ip = | bcip=] [dns_ip=] [domain=] [host nam e=1 host=] [tcp=] [mac=] [dhcp=] Description: Establis hes the network settings.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 29 mac= This displays the M AC address of the unit. (T he default is 00 :0C:8B:SS:SS:SS , where SS:SS:SS is the he x value of the serial nu mber of the unit). Note: T he MAC address ca nnot be changed, it can o nly be displayed.
Connect Tech Blue Heat/Net Sync User Manu al 30 Re vi si on 0. 03 se rver_ip= | sip= Specify the Server IP address from which the file is to be d ownloaded. file= Specify the file na m e to do wnload. If the – jf fs option is chosen, the n the file= option is mandator y.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 31 WCM (Web C onfiguration Man ager) Signing In to th e Web Configuratio n Manager You will need to kno w the IP address of your Blue Heat/Net Sync unit before you use the Web Configuration Manager.
Connect Tech Blue Heat/Net Sync User Manu al 32 Re vi si on 0. 03 Figure 14 : Blue Hea t/Net Sync Settings.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 33 Configure Advanced Seria l Settings The Web Configuration Manager also allo ws y ou to co nfigure more advanced serial po rt properties.
Connect Tech Blue Heat/Net Sync User Manu al 34 Re vi si on 0. 03 • Server IP Address : T his option sets the server IP addr ess. This is used as the Server address to use when bo otp mode or TFTP mode is enabled . The default Server IP address is 0.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 35 Figure 15 : Config uring Blue Heat/Net Sync Settings Configure Fir m ware This section enables you to download new firmware to the B lue Heat/Net Sync unit. Se lect a download source and a specific firmware file path, if app licable, and then submit the do wnload request.
Connect Tech Blue Heat/Net Sync User Manu al 36 Re vi si on 0. 03 NOTE: T his function is not currentl y operational. Figure 17 : Resto re Default Settings Saving To Flash When you make confi guration changes, the chan ges are stored temporarily in me m ory.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 37 Figure 18 : Sav ing To Flash If you haven't made any co nfiguration changes, the Save To F lash button will re m ain gre y.
Connect Tech Blue Heat/Net Sync User Manu al 38 Re vi si on 0. 03 Monitor Network Traffic This page allo ws you to view all network activity on your Blue Heat/Net.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 39 Use this link to find infor mation such as device serial n umber, runtime software versions and firmware versions.
Connect Tech Blue Heat/Net Sync User Manu al 40 Re vi si on 0. 03 Software Insta llation for Win do w s The Blue Heat/Net S ync is designed for eas y installation an d set up. This section deals with i nstalling and usin g the Blue Heat/Net Sync software to co mmunicate with your Blue Heat/Ne t Sync .
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 41 Figure 25 : Blue Heat/Net Sync Software Installation Screen.
Connect Tech Blue Heat/Net Sync User Manu al 42 Re vi si on 0. 03 The Blue Heat/Net Configuration Manager Setup Wizar d will begin. Click Next to start.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 43 The installer will install t he Configuration Manager i nto C: Program FilesCTIBlue Heat N et . If you‟d prefer an alternate locat ion, specify in the space pro vided, or click Br owse to locate the new folder.
Connect Tech Blue Heat/Net Sync User Manu al 44 Re vi si on 0. 03 Running the Configu ration Manager If you chose the optio n to launch the Bl ue Heat/Net Sync Co nfiguration Manager after installation, the main Configuration Manager window should now be open on your s creen.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 45 Configure Default B lue Heat/Net Sync You can choose this o ption when you r Blue Heat/ Net Sync still has a fac tory default IP addr ess of 192.
Connect Tech Blue Heat/Net Sync User Manu al 46 Re vi si on 0. 03 Auto Discover Blue Heat/Net Sync The auto discover will broadcast a message to all the Blue Hea t/Net Sync devices on your network. Upon receiving the b roadcast packet, the Blue Heat /Net Sync device will r espond.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 47 Firmware Up grades If you need to re -install your current fir mware, it is located in the firmware directory of the CD you received with your B lue Heat/Net Sync. Newer firmware versio ns are available from Connect T ech‟s website , http://www.
Connect Tech Blue Heat/Net Sync User Manu al 48 Re vi si on 0. 03 Software Dev elopment Hardware Info r mation The information provided in this section will offer d ata pertaining to the hard ware components present within the Blue Heat/Net S ync unit.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 49 Interrupt s INT * Usage /INT1, /INT2 IUSC logically or-ed interrupts. IUSC Interr upts can be muxed to any of the t w o INT s. One use is to mux all po rts configured for Async mode to o ne IRQ and all ports configured for Sync mode to another interrupt.
Connect Tech Blue Heat/Net Sync User Manu al 50 Re vi si on 0. 03 Memory Map of IUS C and PLD Functio ns ColdFire (5272) Bu s: A ColdFire CS# signal is u sed to select the entire region, setup with th.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 51 A[5..1] Addresses IUSC registers (see Me mory Map Table below). A[0] Not used explicitl y, A0 (along with BS0# and BS1# ) select byte size portions of IUSC registers. PLD Resource Acce ss : A[12] Must be one (1 ).
Connect Tech Blue Heat/Net Sync User Manu al 52 Re vi si on 0. 03 Address Offset (in hex) Area (ite m ) Accessed Register Accessed Notes Writes go to the T ransmitter FIFO Reads come fro m th e Receiv.
Connect Tech Blue Heat/Net Sync User Manual Revision 0. 03 53 Address Offset (in hex) Area (ite m ) Accessed Register Accessed Notes 1A0 1A9 --- --- Reserved, do not access 1AA IUSC-0 Dreg RBCR 1AC IU.
Connect Tech Blue Heat/Net Sync User Manual 54 Revis PLD Registers: Offset Reg Na m e R/W Valid Bit Bit Descriptions Reset Values (Hex) 1000 RTCU Real Time Clock Upper R/W D15.
Connect Tech Blue Heat/Net Sync User Manual Revision 0.01 55 1008 100C 1010 1014 LIF C 1,2,3,4 Line I nt erface Control 1008= Port 1 100C = Port 2 1010 = Port 3 1014 = Port 4 R/W D15.
Connect Tech Blue Heat/Net Sync User Manu al 56 R e v i s i o n 0 . 03 1018 PLD_CNT RL Control Bits R/W D15..0 Control Bits: Rea d/Write only as a 16 Bit word. 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 I M[3] I M[2] I M[1] I M[0] TRG[3] TRG[2] TRG[1] TRG[0] X X IABT SMIE SR[3] SR[2] SR[1] SR[0] SR[3.
Connect Tech Blue Heat/Net Sync User Manual Revision 0.01 57 System Block D i agrams.
Connect Tech Blue Heat/Net Sync User Manu al 58 R e v i s i o n 0 . 03.
Conn ect Tech Blue Heat/Net Sync Use r Manual Revision 0.01 59 Port Settings , Clock Setup and General Set tings Required [condition s] Optional [co nditions] (blank) means setting para meter is not required fo r the mode. TBD means To be Deter mined at a la ter date.
Connect Tech Blue Heat/Net Sync User Manu al 60 R e v i s i o n 0 . 03 Serial Mode ( smode ) BHN_Port Settings Async MonoSync BiSync Trans-BiSync HDLC sync_addr.rx0 Required Required Required Required sync_addr.rx1 Required Required Optional sync_addr.
Conn ect Tech Blue Heat/Net Sync Use r Manual Revision 0.01 61 IUSC Clocking Logic: The following diagra m was scanned from the IUSC manual page 4 - 3 and corrections have been made. Do not use the diagra m from the IUSC manual, use the corrected version w e have provided below.
Connect Tech Blue Heat/Net Sync User Manual 62 Revision 0.01 62 Appen dix Blue Heat/Net Syn c Specifica tions Operating Environ ment 4 port model: 0ºC to 60 ºC (32ºF to 158ºF) Communications Baud Rates: Synchronous : Up to 9.216 M bps w ith internal reference clo ck, up to 10 M bps with external re ference clock.
Connect Tech Blue Heat/Net Sync User Manual Revision 0.01 63 63 Protocol Des criptions The Blue Heat/Net Sync supports a variet y of protocols. The follo wing is a brief explanation of each and how they are i mplemented. ARP Address Resolution Pro tocol, a method used to find a unit‟ s Ethernet MAC address fro m its Internet address.
Connect Tech Blue Heat/Net Sync User Manu al 64 Re vi si on 0. 03 Pinouts DB -25 Female Pino uts DB25F Line Mode Pin # Signal Name V.28 in brackets V.35 EIA- 530 RS232 (V.28) EIA- 530A X.21 (V.11) 14 TX+ V.35 [4] V.11 Hi -Z V.11 V.11 2 TX - (TX) V.35 [4] V.
Connect Tech Blue Heat/Net Sync User Manual Revision 0.01 65 65 DB -9 Female Pinout s DB9F Pin Signal Name [1] Functional Notes 1 RTC_Clear Clears and holds the seconds count of the Real Time Clock at 00. [3], [6] 2 RTC_Seconds Provides the external time base for the Real Time Clock.
Connect Tech Blue Heat/Net Sync User Manu al 66 Re vi si on 0. 03 Multi-drop Commu nications Using V.1 1 / RS422/RS485 Li ne Mode s When wiring multi -drop RS -4 85 networks, it is necessary to wire the devices in a “Dai sy Chain”, they must not b e wired with a “Star” topo logy, see diagram.
Connect Tech Blue Heat/Net Sync User Manual Revision 0.01 67 67 Default Settings Network Settings Blue Heat/Net Sync IP address 192. 168.42.1 Server IP address 0.0.0.0 (used for firmware do wnloads) Gateway IP add ress 0 .0.0.0 Subnet Mask 25 5.255.255.
Connect Tech Blue Heat/Net Sync User Manu al 68 Re vi si on 0. 03 Common Co nfiguration Setup s Static IP Setup In some networking enviro nments it is best to have the IP address set to a fixed val ue. The advantage is that since it i s fixed, connecting to it can be a lot simpler.
Connect Tech Blue Heat/Net Sync User Manual Revision 0.01 69 69 DHCP Setup In many modern net w orks IP numbers ar e not static but are auto matically assigned b y a DHCP server and can change over ti me or on each po w er up. DHCP must be enabled on the Blue Heat/Net Sync beca use it is shipped to use a default static IP (192.
Connect Tech Blue Heat/Net Sync User Manu al 70 Re vi si on 0. 03 Bootup Sequence Figure 30 : Boo tup Sequence Boot from Flash Enabled? Decompre ss uClinux from F lash to SDRAM Bootp Enabled? Y Y N Ob.
Connect Tech Blue Heat/Net Sync User Manual Revision 0.01 71 71 Flowchart of Specia l Operations Mode using th e reset butt on Figure 31 : Boot up Sequence via Reset Butt on Asynchronous C ommunications Tuto rial The Blue Heat/Net S ync features four synchrono us/asynchronous serial communicatio n po rts.
Connect Tech Blue Heat/Net Sync User Manu al 72 Re vi si on 0. 03 Figure 32 : Typical A synchronous Date F rame Serial Line Inte r face Tu torial RS -232 Line Interfa ce: RS -232 is the si mplest, least expensive li ne interface standard , the Sipex trancei vers used on the Blue Heat/Net Sync re fer to RS232 as V.
Connect Tech Blue Heat/Net Sync User Manual Revision 0.01 73 73 mode RS -48 5 is fully compatible with RS -422; which is consid ered a subset of RS - 485. The use of differential tran smitters and receivers e nsures RS -485 communications are reliable and robust.
Connect Tech Blue Heat/Net Sync User Manu al 74 Re vi si on 0. 03 Multi-drop 4-Wire, Ful l Duplex Co mmunications: In a multi-drop 4-wire differntial net work, two to 32 d evices are connected together. Note t hat each RS-485 receiver c ounts as a d evice or “load”.
Connect Tech Blue Heat/Net Sync User Manual Revision 0.01 75 75 Bus Contention on D ifferential Multi-drop Networks: Bus contention occurs when two or more devices enabled on a bus attempt to run the bus to opposite logic values. Fro m the diagra m above, we can se e that there ar e multiple differential transmitters (TXD) o n the bus.
Connect Tech Blue Heat/Net Sync User Manu al 76 Re vi si on 0. 03 Termination Resist ors in Different ial N etworks Termination Resi stors in Differential Networks: Differential net w orks often be nefit from the installation o f termination resistors.
デバイスConnect Tech CTIM-00044の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Connect Tech CTIM-00044をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはConnect Tech CTIM-00044の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Connect Tech CTIM-00044の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Connect Tech CTIM-00044で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Connect Tech CTIM-00044を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はConnect Tech CTIM-00044の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Connect Tech CTIM-00044に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちConnect Tech CTIM-00044デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。