ContinentalメーカーUSAC-8の使用説明書/サービス説明書
ページ先へ移動 of 12
Technical Guide Form UTG-0204 Continental Chillers LLC UniPac ™ Single Phase Air Cooled Chillers Water Cooled Chillers Split System Chillers 3 through 60 HP Phone: 317-337-9813 Fax: 317-337-9816 www.
Phone: 317-337-9813 www.continentalchil lers. com Fax: 317-337-9816 Continental Single Phas e Chillers UniPac™ Introducing UniPac™ Chiller Systems All over the world, Continental has successfully developed and marketed va rious packaged and split chillers to serve many needs.
Phone: 317-337-9813 www.continentalchil lers. com Fax: 317-337-9816 Continental Single Phas e Chillers UniPac™ Standard Unit Specifications of UniPac™ Single Phase Chillers General Description Con.
Phone: 317-337-9813 www.continentalchil lers. com Fax: 317-337-9816 Continental Single Phas e Chillers UniPac™ UniPac™ Options and Selection Procedures 1.
Phone: 317-337-9813 www.continentalchillers.com Fax: 317-337-9816 Continental Single Phase Chille rs UniPac™ Single Phase Air Cooled Ratings Models USAC-3 through USAC-20 3 through 20 Tons Ambient Air Temperature °F 85 95 105 115 120 LCWT °F Model USAC TR kW Cooler GPM TR kW Cooler GPM TR kW Cooler GPM TR kW Cooler GPM TR kW Cooler GPM 3 2.
Phone: 317-337-9813 www.continentalchillers.com Fax: 317-337-9816 Continental Single Phase Chille rs UniPac™ Single Phase Air Cooled Ratings Models USAC-25 through USAC-60 25 through 60 Tons Ambient Air Temperature °F 85 95 105 115 120 LCWT °F Model USAC TR kW Cooler GPM TR kW Cooler GPM TR kW Cooler GPM TR kW Cooler GPM TR kW Cooler GPM 25 21.
Phone: 317-337-9813 www.continentalchillers.com Fax: 317-337-9816 Continental Single Phase Chille rs UniPac™ Single Phase Water Cooled Ratings Models USWC-3 through USWC-60 3 through 60 tons Condenser Leaving Water Temperature, °F 85 95 100 LCWT °F Model USWC TR kW Cooler GPM Cond GPM TR kW Cooler GPM Cond GPM TR kW Cooler GPM Cond GPM 3 3.
Phone: 317-337-9813 www.continentalchillers.com Fax: 317-337-9816 Continental Single Phase Chille rs UniPac™ USAC Physical Data USAC-3, 4, 5, 8 USAC-10, 12, 15, 20 USAC-25, 30 USAC-40, 50, 60 Dimensions Water Connections Model USAC L” W” H” Weight, lbs.
Phone: 317-337-9813 www.continentalchillers.com Fax: 317-337-9816 Continental Single Phase Chille rs UniPac™ USWC Physical Data USWC-3, 5, 10 USWC-15, 20 USWC-25, 30 Dimensions Water Connections, Inlet”/Outlet” Model USWC L” W” H” Weight, lbs.
Phone: 317-337-9813 www.continentalchillers.com Fax: 317-337-9816 Continental Single Phase Chillers UniPac™ Electrical Data USAC Packaged Air Cooled Chillers Total Unit Compressor Motor Da ta Condenser Fan Motor Data Standard Unit Optional Low Ambient Unit Single Phase/Single Speed Motor Single Phase/Speed Control Model MCA Max Fuse Rec.
Phone: 317-337-9813 www.continentalchillers.com Fax: 317-337-9816 Continental Single Phase Chillers UniPac™ Installation and Application Data General Continental UniPac™ Air Co oled Packaged Chillers models USAC are designed for outdoor installat ions and nor mal exposure to s ummer and winter condit ions.
Continental Single Phase Chillers UniPac™ UniPac™Guide Spec Furnish and install where indicated on plans Qty______ Continental UniPac™ model (USAC, USWC) ________ _ packaged liquid chiller(s).
デバイスContinental USAC-8の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Continental USAC-8をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはContinental USAC-8の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Continental USAC-8の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Continental USAC-8で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Continental USAC-8を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はContinental USAC-8の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Continental USAC-8に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちContinental USAC-8デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。