Agilent Upgrade Guide for the 8510 V ector Network Analyzer Product Note 85107B, 45 MHz to 50 GHz in coax 8510XF on-wafer configuration 85106D with option 001, 45 MHz to 50 GHz in coax, above 50 GHz i.
2 3 5 5 6 7 8 9 9 9 10 11 11 11 11 12 13 15 15 16 17 17 19 T able of Contents V ector network analyzer (VNA) overview Agilent 8510 family of products Agilent 8510 network analyzer Agilent 8510 firmwar.
3 Figure 1. Device characterization DUT Processor/Display Receiver/Detector Signal separation Source Incident Reflected Transmitted Incident Reflected Transmitted Figure 2.
4 8510 VNA system Source 8360 Test set 851X Receiver/detector 8510 processor/display network analyzer Signal separation Stimulus = + + Figure 3. 8510 measurement systems are made up of modular components, the 8510 network analyzer , a test set and a compatible source.
5 Agilent 8510 network analyzer Tables 1 and 2 sho w the different features of t he 8510A, B, and C, hardware and f irmware, respectively. T able 1. Hardware revision and measurement capability Product Firmware revisions Hardware features 8510A A.02.00 • T ape drive 8510B B.
6 T able 2. Firmware revision and measurement capability Revision Time domain 1 Pulse 2 Power domain Other added key features limit lines A.02.00 B.03.00 • Adapter removal calibration • Direct control of two sources B.03.11 • Direct control of up to 4 test sets B.
T est Sets The t est set in a VNA measurement system is used t o separate t he inci- dent, t he ref lected, and the transmitted signals. It is also used t o conver t the RF signal t o IF (inter mediate fre- quency) signal and to pass t he IF to the receiver .
8 Sources The RF or micro wav e signal source in a VNA measurement system pro vides the incident signal used to stimulate the device-under -test (DUT). The DUT responds by ref lecting par t of the incident and transmitting t he remaining part. By sweeping the frequency of t he source, the frequency response of t he DUT can be deter mined.
9 Upgrade considerations There are numerous reasons for upg rading the Agilent 8510 syst em. The 8510 netw ork analyzer maint ains ex cellent per f or mance while adapting to different measurement requirements such as basic component testing, on-waf er probing, pulsed device characterization, antenna and RCS (Radar Cross Section) meas- urements.
10 Upgrading the 8510 to the 8530 microwave receiver for antenna measurements Figure 7 belo w illustrates ho w the 8510C can be upg raded t o eit her an 8530A or 8530A and 8510C. F or example, to upgrade an 8510C to an 8530A, order 85395C wit h Option 111.
11 T est set upgrades A sing le 8510 network analyzer can be conf igured to control up to f our test sets. The operat or can switch between test sets, without reconnections, using front panel controls. This arrangement is oft en referred to as the multiple test set configuration.
12 Upgrading systems Figure 8 sho ws the different 8510 systems and their components. This figure is an excellent guide when upgrading systems. Figure 8.
13 Here is a checklist of it ems t o consider when upgrading systems: 1. Which 8510 do I have? The 8510C is recommended for the latest available measurement capabilities. • To upgrade an 8510A t o an 8510C, order 85103E. • To upgrade an 8510B t o an 8510C, order 85103F .
14 Upgrades for 85107B, 85109C Upgrade consists of tw o test heads, a millimet er t est set controller , an 83621B for LO source, and rack. It does not include calibration kits or t est por t cables.
15 Examples of upgrade paths Figure 10. Upgrading an 85107B 50 GHz system to an 85106D waveguide system to operate in V -band (or W -band) Measurement accessories There are measurement accessories f or seven device connect or types: 7 mm, 3.5 mm, 2.92 mm, 2.
16 Calibration kits Error correction requires t hat t he syst ematic er rors in the measurement system be charact erized by measuring kno wn devices (st andards) ov er the frequency range of interest with the process of calibration. All calibration kits contain st andards used for this purpose.
17 V erification kits V erification kits are used to verify the per formance specif ications of an 8510 system. All kits include a precision Z o airline, mismatched airline and fixed attenuators. Measured data and uncert ainties traceable t o t he U.S.
18 Configuration B. This cable ar rangement is for applications where the device under t est is connected between cable ends. This setup of fers more f lexibility when connecting t o t he device under t est. For 8514B/8515A/85110A test sets (3.5 mm rugged test port connectors) Cables/adapter Connector type (on device side of cable/adapter) For 3.
19 Related literature Pub. number Agilent 8510 N etwork Analyzer , Color Brochure 5091-8970E Agilent 8510 System Solutions 5965-8837E Agilent 8510 Family Network Analyzer , Configuration Guide 5091-89.
Agilent T echnologies’ T est and Measurement Support, Services, and Assistance Agilent T echnologies aims to maximize the value you receive, while minimizing your risk and problems. W e strive to ensure that you get the test and measure- ment capabilities you paid for and obtain the support you need.
デバイスAgilent Technologies 85107Bの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Agilent Technologies 85107Bをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAgilent Technologies 85107Bの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Agilent Technologies 85107Bの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Agilent Technologies 85107Bで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Agilent Technologies 85107Bを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAgilent Technologies 85107Bの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Agilent Technologies 85107Bに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAgilent Technologies 85107Bデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。