CP-07BL O W ater F iltration De vice • Thisproductcannotbeusedifthevoltageisdier entfromthat mentionedintheratingplate . • Fory oursafetyandproperuseoftheproduct,pleasereadthis User’ sM anualbeforeuse .
1 F E A T U R E S 2. F aucet pollution prevention Itprotectsthecoldwater/theroomwaterfauc etfromthe externalpollutionusingthefaucetcover .
2 DEAR CUST OMERS FEA TURES / CONTENTS - Please keep the User’ s Manual where it can be readily reached or f ound - Thankyouforusingour Co way W ater F iltration Device . PleasereadthisUsers ’ M anualtouseandmaintaintheproductcorrectly .
3 SAFETY INFORMA TION Be careful to keep this saf ety information. Pleasereadthisinformationt opreventpr opert ylossandensureyoursafety . Electricit y safety Do not use a damaged power cor d or plug, and loose outlet. Other wise,electricshockor remayoccurasaresult .
4 Remove an y dust or water o in the pin and contacts of the power plug. Other wise,electricshockor remayoccurasaresult . When you don ’t use for a long time, close the main water supply valv e and unplug. Other wise,electricshockor remayoccurasaresult .
5 T o drink the filtered water , change the lter accor ding to the lter replacemen t cycle. Ifyouusetheexpir edlter ,the lterperformanceislowered. SAFETY INFORMA TION When you don ’t use for a long time, use after draining the sav ed water complet ely and emptying the newly room water onc e again.
6 Do not clean by spraying the water directly or don ’t wipe the product using the benzene and thinner . Other wise,electricshockor remayoccurasaresult . Clean after unplugging. Other wise,electricshockor remayoccurasaresult .
7 P ARTS NAME Indication part/ Operation part Room water extraction faucet Cold wa ter extraction faucet Cup-touch lever Gutte r Fr ont Cooling Stopper Radiator Po wer cord Inlet(Orange) Outlet(Blue) .
8 W A TER FIL TRA TION PROCESS Uses of disposed water - Thedailylifewat ershouldbeusedforcleaningtherestroom,thehouse ,clothes,or purposesotherthandrinking. - Neverusethedailylifewat erforadrinkingwateroracook.
9 INST ALLA TION PRECA UTIONS Do not turn the water pipe . Shall install the adaptor with connector on the cold water pipe . Flush wat er through each lter at least 5 minutes before C onnection. 1. Close main water supply valv e to separate the fauc et.
10 The summary for the proper installation of the w ater ltr ation devic e Please check before use! This product is for 120 V 60 Hz only . Pleaseconnectthepowerplugtoadedicatedg roundedelectrical outletfor120 V 60H z.
11 OPERA TION / INDICA TION P ART W aterlevel indicator Po wersaving modeindicator Lightsensor Po werindicator Coldwater temperature indicator W ater level indicat or Theindicatorislightened accordingtothew aterlevel ofthestoragetank.
12 T o use the power sa ving mode T o use the cold water mode Press the “COLD” in the right of the control button and check if the cold water mode indicator in the indication part is turned on. If you want to turn off the cold water mode, press the selection button once more.
13 How T o Use HOW TO USE Pleasepushthecup-touchleverintheroomwater faucet. Pleasepushthecup-touchleverinthecoldwater faucet.
14 INST ALLA TION F ollow the instruction for installation Inlettubing(Orange) Outlettubing(Blue) 1coolingstopper 120 V 60HzOnly ▶ ▶ Mainwater supplyvalve Connecttheorangecolorinlettubing 1 tothe tapwatersupplyingpipe.
15 INST ALLA TION W ater ltra tion device installation plac e 1 Pleaseinstallthewaterltrationsy stemnotataroughplace , adampplace,aplacewher e.
16 CLEANING METHOD 4. Shake and clean a cer amic lter in the taken wat er by rotating and separating it from the c old water/r oom water separ ation board . Stor age tank 2. Please drain and take the w ater inside of the wat er ltration device completely using the draining hose .
17 CLEANING METHOD 7. Close the storage tank c over after rota ting and equipping the ceramic lter in the cold wa ter/room wa ter separation boar d. 6. Use the storage tank after cleaning it with the taken wat er , draining completely using the draining hose , and empt ying the newly room water one time or mor e.
18 1. Gutter separation method 2. Gutter assembling method Theguttercanbesepa ratedeasilywithliftingupthe frontpartofthegutterandtakingout. Y oujustpushthehookofthegutterslightlyafter stickingtotheproduct.
19 FIL TER REPLA CEMENT Filter Thelifeofthewat erltrationsystemisthelter .Ititisn’tthe legitimatedlterory ouusetoolongevenifitisthelegitimatedlt er , thelterperformancecanbelowered.
20 FIL TER REPLA CEMENT ME THOD 1. Close the main water supply valv e after unplugging the power cor d, and drain the wat er inside of the water ltr ation device (See P .16). 2. Open the upper cover and separa te the gutter in the front side . 3. Please lift the cup -touch lever up after closing the faucet using the faucet cap .
21 FIL TER REPLA CEMENT ME THOD 4. After releasing 2 x ed screw in the upper side of the product using the driver , pulling for ward with grasping the upper side of the fr ont co ver . 5. After separating the tting connected to the lter trying to replace , please replace the lter .
22 TROUBLESHOO TING Symptom Check Measures to take Thewatertastes weird. • Didyoucleanthestoragetank? Cleanthestoragetank. • Y oudidn’tusethew aterltrationdevice foralongtime.
23 SPECIFICA TION Product W ater Filtr ation Device Model CP-07BL O FiltrationMethod RO(ReverseOsmosis) Pow erSupply 120 V~60Hz T ank Capacity RoomW ater 5.
24 W A TER FL OW DIA GRAM CP-07BL O SPECIFICA TION / W A TER FLOW DIA GRAM Others.
25 W ater Filtr ation Sy stem P er formance Da ta Sheet Brand: L yon II Model: CP-07BL O Thissystemhasbeentestedandc ertiedbytheW aterQualityAssociationaccor dingtoNSF/ANSI42,53,and58for thereductionofthesubstanceslistedbelow .
26 • Forpartsandserviceavailability,pleasec ontactyourlocaldealerorCoway . • Thissystemisacceptablef ortreatmentofinuentconc.
27 Chemical Drinkingwaterregulatory level 1 (MCL/MAC)mg/L Inuentchallenge concentration 2 mg/L Chemicalreduction percent Maximumproductwater concentrationmg/L alachlor 0.002 0.050 >98 0.001 3 atrazine 0.003 0.
28 StateofCalifornia DepartmentofPublicHealth W ater T reatment Device Certicate Number 08 - 1934 DateIssued:September11,2008 T rademark/Model Designation Replacement Element(s) WoongjinC owayCo .
29 What This W arranty Co vers: Commencingwiththedateofpurchaseofthe Productandcontinuingf oraperiodofoneyear , ifmanufacturingdefectsint.
30 Limitations on Implied W arranties: Anyimpliedwarrantyofmerchantabilityor tnessforaparticularpurposeoruse,shallbe limitedtothedurationofthef oregoingexpress writtenwarranty .
http://www.co way .com MADEINKOREA 1208828 001.
デバイスCoway CP-07BLOの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Coway CP-07BLOをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCoway CP-07BLOの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Coway CP-07BLOの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Coway CP-07BLOで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Coway CP-07BLOを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCoway CP-07BLOの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Coway CP-07BLOに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCoway CP-07BLOデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。