Crownメーカー2の使用説明書/サービス説明書
ページ先へ移動 of 21
Models: Power Base -1, 2 & 3 OFF POWER OFF POWER OFF POWER © 1996 by Crown International, Inc., P.O. Box 1000, Elkhart, Indiana 46515-1000 U.S.A. Telephone: 219-294-8000. Power-Tech amplifiers are produced by the Professional Audio Division of Crown International, Inc.
WORLDWIDE SUMMARY OF WARRANTY The Crown Audio Division of Crown International, Inc., 1718 West Mishawaka Road, Elkhart, Indiana 46517-4095 U.S.A. warrants to you, the ORIGINAL PURCHASER and ANY SUBSEQ.
Printed on recycled paper. The lightning bolt triangle is used to alert the user to the risk of electric shock. The exclamation point triangle is used to alert the user to important operating or maintenance instructions.
Power Base Series Power Amplifiers Page 4 CONTENTS 1 Welcome .......................................................................... 7 1.1 Unpacking ................................................................. 7 1. 2 Features .................
Power Base Series Power Amplifiers Page 5 ILLUSTRA TIONS 1.1 Power Base Front and Back Panels .................................... 7 2.1Three System Connection Methods ....................................... 8 2.2Do NOT Block Air Flow ................
Power Base Series Power Amplifiers Page 6.
Power Base Series Power Amplifiers Page 7 1 Welcome Congratulations on choosing a Power Base amplifier. Power Base amplifiers are compact, professional ste- reo power amplifiers engineered to meet the most de- manding sound reinforcement needs.
Power Base Series Power Amplifiers Page 8 MIXER LOUDSPEAKERS + – + – CHANNEL 1 CHANNEL 2 CHANNEL 1 CHANNEL 2 STEREO MODE BRIDGE-MONO MODE STEREO BRIDGE MONO PARALLEL MONO PARALLEL-MONO MODE MIXER .
Power Base Series Power Amplifiers Page 9 2 Installation Always remove power from the unit and turn the level controls off (fully counterclockwise) when making or breaking connections. This reduces the chance of blasts that can cause loudspeaker damage.
Power Base Series Power Amplifiers Page 10 2.3 Input Sensitivity Adjustment The input sensitivity switch inside the amplifier is set to 0.775 volts at the factory. It can be changed to 1.4 volts or a voltage gain of 26 dB as follows: 1. Turn off and unplug the amplifier from the AC source.
Power Base Series Power Amplifiers Page 11 3.3.1 ODEP Crown invented ODEP to keep the amplifier working under demanding conditions and to increase output efficiency. To do this, Crown established a rigorous pro- gram to measure each transistor’s safe operating area (SOA).
Power Base Series Power Amplifiers Page 12 The unit should never output heavy common-mode cur- rent unless its circuitry is damaged. Activating drive protection helps prevent further damage. 3.3.4 Transformer Thermal Protection All Power Base amplifiers have transformer thermal protection.
Power Base Series Power Amplifiers Page 13 4 Specifications All specifications apply to units in Stereo mode with 8-ohm loads and an input sensitivity of 26 dB unless otherwise specified. Standard 1 kHz Power: refers to maximum average power in watts at 1 kHz with 0.
Power Base Series Power Amplifiers Page 14 Required AC Mains: Current, frequency and voltage requirements are provided on each unit’s back panel. All models draw 90 watts or less at idle. Power Base-1 : Draws up to 6 amps of current. Power Base- 2 : Draws up to 10 amps of current.
Power Base Series Power Amplifiers Page 15 8 Power Base-1 – Minimum Guaranteed Power (Watts) Stereo-Mono Mode Stereo (both channels driven) Bridge-Mono (balanced output) Parallel-Mono 16 4 0.1% THD + Noise (See note 4) 1 kHz 20Hz-20kHz 180 350 175 350 200 390 390 200 390 390 Maximum Average Load (Ohms) AC Mains 120 VAC, 60 Hz Units 1 kHz 0.
Power Base Series Power Amplifiers Page 16 8 Power Base -2 – Minimum Guaranteed Power (Watts) Stereo-Mono Mode Stereo (both channels driven) Bridge-Mono (balanced output) Parallel-Mono 16 4 FTC Continuous Average 0.
Power Base Series Power Amplifiers Page 17 Maximum Power Specifications Crown’s maximum power specifications represent the largest amount of output power you can expect from your amplifier when it is driven to full output under the given conditions.
Power Base Series Power Amplifiers Page 18 8 Power Base -2 – Maximum Power (Watts) Stereo-Mono Mode Stereo (both channels driven) Bridge-Mono (balanced output) Parallel-Mono 16 4 40 Millisecond Tone Burst 0.
Power Base Series Power Amplifiers Page 19 5 Accessories There are two accessories available at the time of this printing: the MT-XLR and the MT-BB . Important: The MT-XLR and MT-BB must be installed at a Crown Factory Service Center or the Crown factory.
Power Base Series Power Amplifiers Page 20 6 Ser vice This unit has very sophisticated circuitry which should only be serviced by a fully trained technician. This is one reason why each unit bears the following label: CAUTION: To prevent electric shock, do not re- move covers.
Power Base Series Power Amplifiers Page 21 Crown Factor y Ser vice Information Shipping Address: Crown International, Inc., Factory Service, Plant 2 SW, 1718 W.
デバイスCrown 2の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Crown 2をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCrown 2の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Crown 2の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Crown 2で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Crown 2を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCrown 2の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Crown 2に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCrown 2デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。