1450digser vice REV 12/6/0 5 SER VICE MANU AL (DOMESTIC ) IMPING ER CONVEYOR OVE NS MODEL 1450,1451 WITH PUSH BUT TON C ONTROLS Lincoln Foo dservice Products, Inc. 1111 North Hadley Road P.O. Box 1229 Fort W ayne, Indiana 46801-1229 Phone : (800) 374 -3004 • Fax: (260) 436 -0735 Technical Service Hot Line (800) 678-9 511 www.
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 2 SEQUENCE OF OPERATION IMPINGER ADVANTAGE SERIAL NUMBER N2865 4 AND A BOVE (OVENS WITH P USH BUTTON CONTROLS) MODEL 14 50 120VAC 60 HZ. NAT. GAS MODEL 14 51 120VAC 60 HZ. LP GAS POW ER SUPPLY Electrical po wer is supp lied to th e oven b y a three c onductor c ordset.
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 3 SCHEMATIC DI AGRAM MODEL 1450, 1451 SERIAL NUMBER N2865 4 AND A BOVE.
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 4 TROUBLESHOOTING GUIDE IMPINGER ADVANTAGE GAS OVENS SERIAL NUMBER N2865 4 AND A BOVE (OVENS WITH P USH BUTTON CONTROLS) SYMPTO M POSSIBLE CAUSE EVALUATION Oven fan wi ll not run Incom ing power supply Check circuit break er, reset if required.
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 5 not running, ch eck for opens, shor ts or gr ounds. W ITH POW ER OFF: Turn m otor to check for lock ed rotor. Replace burner blower m otor as ne eded. Burner trans form er Check for 120VAC su pplied to pr imar y of burner transform er.
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 6 the displa y, replace oven contr ol. If there is a read-out on the contro l, set the control to max imum tem perature (see Installat ion operat ions m anual for temper ature adjustm ent). W ith the control set at m aximum temper ature, check for 120VAC at the tem peratur e regulation valve.
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 7 Control transf orm er Check for 120VAC suppl y to the pr imar y of the control transform er. If no voltage is prese nt, trace wiring bac k to the oven power s witch. If vo ltage is pres ent, chec k foe 24VAC at the transf orm er sec ondary.
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 8 REMOVAL, INSTALLATION & ADJUST MENTS IMPINGER A DVANTAGE SERIES CAUTION! BEFORE R EMOVING O R INST ALLING AN Y COM PONENT IN T HE IMPINGER OVEN BE SU RE TO DISCONNECT ELECT RICAL PO W ER AND GAS S UPPLY MOTO R, MAIN FAN - R EPLAC EMENT 1.
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 9 THERMOST AT , COOLING F AN - REPLAC EMENT 1. Shut off power at m ain break er. 2. Rem ove control pane l top and f ront cover. 3. Rem ove lead wires a nd mark for reassem bly. 4. Rem ove two (2) scre ws and rem ove therm os tat.
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 10 6. Rem ove incoming nip ple. 7. Rem ove pilot tube ass embly from control valve. 8. Disconnect pipe union j ust abo ve solenoi d valve. 9. Disconnect wiring fr om c ontrol valve m aking note of wire num bers and location.
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 11 BURNER IGNIT OR - REPLACE MENT 1. Shut off power at m ain break er. 2. Rem ove control pane l top and f ront cover. 3. Rem ove burner assem bl y. (SEE "BURN ER ASS Y.") 4. Rem ove pilot shield and pilot s hield extens ion.
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 12 REVERSING C ONVE YOR DIRECT ION All ovens le aving our plant are wired to op erate co nveyors f rom lef t to right. T o reverse co nveyor dir ection, use the follow ing proced ure. 1. Shut off power at oven s witch.
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 13 This page in tentionally left blank..
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 14 GENERAL VIEW ADVANTAGE SERIES LETT ER PART NUMBE R D ESCRIPTIO N A 369003 Door hinge B 369110 Access wind ow assem bly C 369337 Retainer (o .
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 15.
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 16 CONTROL BOX – 1450, 1451 S/N N28654 and ABOVE LETT ER PART # DESCRIPT ION A 369263 Gas Valve B 369344 Pilot Shut Of f Valve C 369398 Solenoid Valve Nat/L P D 370059 Manifold, Burner E 369072 Main Orific e, Nat.
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 17.
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 18 OVEN BA CK ADVANTAGE SERIES GAS AND ELE CTRIC LETT ER PART NUM BER DESCRIPT ION A 3698 08 C over, m otor (gas ove ns) 370140 Cover, m otor (electric ovens) B 3698 00 Motor , main f an (60 H z.
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 19.
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 20 CONVEYOR 1450 SE RIES LETT ER PART NUM BER DESCRIPT ION 369830 Com plete conve yor assembl y A 369816 Conve yor belt 370092 Conve yor belt, .
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 21.
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 22.
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 23.
Impinger I – 1450 Ser ies Ser vice Manua l - Dom estic 24.
デバイスCub Cadet 1451の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Cub Cadet 1451をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCub Cadet 1451の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Cub Cadet 1451の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Cub Cadet 1451で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Cub Cadet 1451を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCub Cadet 1451の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Cub Cadet 1451に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCub Cadet 1451デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。