Culligan ® Iron-Cleer ® Automatic Water Filter Owners Guide.
.
THANK YOU AND WELCOME TO YOUR NEW WORLD OF BETTER LIVING WITH CULLIGAN WATER. The Culligan ® Iron Cleer ® water filters have been tested and certified by WQA against WQA-200 for the effective reduction of iron up to 1,400 gallons for 10” units and 2,000 gallons for 12” units.
Table of Contents 4 S p e c i f i c a t i o n s ...................................................... 1 I n t r o d u c t i o n ....................................................... 2 O p e r a t i n g C o n d i t i o n s ..........................
Specifications Culligan ® Iron Cleer ® Filters 1 Capacity based on 4 gpm and 10 mg/L of dissolved iron. 2 Measured from top of media bed to top of inlet fitting. 3 Max flow rates & pressure drop characteristics have not been validated by the Water Quality Association.
Introduction Operation Step 1. Aeration Operation Service Cycle In the service cycle, raw water enters the inlet port of the aeration tank and is directed through the inlet diffuser. The oxidation process begins when the water passes through the inlet diffuser and cascades through a head of air.
Shuttle Valve Operation In the service position, water pressure holds the shuttle valve piston in the closed position, trapping the airhead in the aeration tank and closes the air recharge inlet port and drain port. During air recharge cycle, air pressure is greater than the water pressure and forces the shuttle valve piston in the open piston.
The concentration limits listed below reflect the maximum individual limit that each contaminant was tested for separately without any interference of other contaminants in the influent water.
Fam ilia riza tio n Power Loss The AccuSoft ® circuit board is equipped with a Hi-Cap Capacitor and EEPROM memory chip. The capacitor is capable of maintaining the time, for at least two days, in the event of a power outage. The EEPROM ensures that the individual programming parameters of your filter are not lost.
Programming 6 Make sure either inlet water supply is turned off, then supply power to the timer. The display will power up ashing “12:00 PM” and the motor will energize and cycle the control, without stopping, the home position. This is required to ensure that the control is in the home position.
7 Pressing the “Status” key will save the setting and move to the next programming step. Settline Time This setting is used to set the time in minutes for cycle 2. This cycle is usually brine draw / slow rinse for softeners and a settling time for lters.
Normally , all water except outside lines passes through the water lter . There are times when the water lter should be bypassed, using the Cul-Flo-V alv ® Bypass, or a 3-way bypass valve.
9 Aeration T ank – Bypass V alve Operation Normal Operation Bypass Operation “T reated” Water Exits Supply W ater Enters Supply W ater Exits Supply W ater Enters Shut-Off Mode No W ater Exits Su.
Things to Check Before You Call for Service If you unexpectedly experience problem water, make these simple checks before calling your Culligan dealer.
Care and Cleaning of Your Water Conditioner 11 Following these simple precautions will help assure continued trouble-free service and keep your Culligan W ater Conditioner looking like new for years. 1 Use only mild soap and warm water when cleaning the exterior of the conditioner .
Preventative Maintenance Recommended Preventative Maintenance The Culligan Iron Cleer water filter has been designed to provide a good, consistent service life. Because of the nature of problem water, we recommend that the local Culligan dealer provide regular maintenance/service contracts for the proper operation of your systems.
T r ou bl e sh oo t i n g Guide 13 Complaint Problem Cause Solution Iron bleed- through or staining. A. Inadequate backwash of filter 1. Plugged drain line flow control 1. Call your Culligan dealer for service. 2. Insufficient water supply from well. 2.
Complaint Problem Cause Solution Water leaking from relief valve. A. Dirt lodged under seat of valve. 1. Pressure has exceeded rating on relief valve and caused valve to open 1. Call your Culligan dealer for service. B. Faulty or defective relief valve 1.
15 Complaint Problem Cause Solution Excessive noise during regeneration. A. Howling or whistling noise during regeneration cycle. 1. Inadequate drain line size. 1. Call your Culligan dealer for service. 2. Drain line is vibrating against other pipes, conduits, pipe hangers, heat ducts, floor joists,etc.
Performance Data Sheet Culligan ® 10” and 12” Iron-Cleer ® Water Filters Important Notice — Read this data sheet and compare the capabilities of the unit to your actual water treatment needs. Culligan recommends that you have your water supply tested to determine these needs before purchasing a water treatment unit.
17 Records and Data Important Data on Your Water Filter It is advisable to have the salesperson or installer fill in the information below for your future reference. If this has not been done, please ask for it, as it is necessary if you contact your dealer.
Culligan Limited Warranty Culligan ® Iron-Cleer ® Automatic Water Filters You have just purchased one of the finest water filters made. As an expression of our confidence in Culligan International C.
With Culligan You Get More Than A Quality Product You Get Your Water Expert, The Culligan Man We’re here to provide you with fast, dependable service, making sure any problems you have are taken care of. The Culligan Man has been around for over sixty years, delivering dependable service all along.
デバイスCulligan Iron-Cleerの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Culligan Iron-Cleerをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCulligan Iron-Cleerの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Culligan Iron-Cleerの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Culligan Iron-Cleerで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Culligan Iron-Cleerを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCulligan Iron-Cleerの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Culligan Iron-Cleerに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCulligan Iron-Cleerデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。