CunoメーカーSQC Seriesの使用説明書/サービス説明書
ページ先へ移動 of 17
© 2001 CUNO Incorporated 98-880040 1101 SQC Series Owner's Manual This Manual is for the Installation, Operation, and Maintenance of the WATER FACTORY SYSTEMS ® SQC Series Reverse Osmosis (RO) .
INTRODUCTION This manual explains the installation, operation and maintenance of the Water Factory Systems ® SQC Series Reverse Osmosis (RO) Drinking Water Appliances. Please read each section of this manual carefully. The specific model chosen should be appropriate for the local water conditions and the customer's needs.
.
A. DETERMINE THE APPLIANCE LOCA TIONS The appliance can be located under a sink or in a base- ment depending on space availability and the customer's pref- erence.
C. PREP ARE THE APPLIANCE FOR INST ALLA TION Open the shipping carton and remove the components. Check to see that all of the installation parts are present. They should include the purification assembly, storage tank, faucet, installation hardware, RO membrane cartridge and tubing.
E. MOUNT THE F AUCET Undercounter installations generally require that the faucet's built-in air gap be used. In basement installations, the built-in air gap does not have to be used if one is provided elsewhere on the drain line. For Basement Installations Without An Air Gap Module See Installation Instructions O.
F . INST ALL THE FEED WA TER T APPING V AL VE AND TUBING The feed water tapping valve which is supplied, is designed to be used on 3/8" to 1/2" OD soft copper tubing (plain or chromed) and rigid metal pipe. Do not use it on flexi- ble ribbed tubing, because it has too thin a wall thickness and it requires special hardware.
G. PREFILL AND SANITIZE THE STORAGE T ANK Prefilling the storage tank is always recommended so that there is pressure to check for leaks as well as sufficient water to flush the carbon postfilter. The SQC RO Drinking Water Appliance is furnished with a container of special sanitizing gran- ules.
I. INST ALL THE PURIFICA TION ASSEMBL Y AND STORAGE T ANK For Basement Installation See Installation Instructions O. Undercounter Installation: The purification assembly is usually mounted to the right or the left side wall inside of the sink cabinet, taking into consider- ation the space available and the tank location.
1 Push in grey collet to release tubing. 2 T ubing is secured in. Grey Collet T ube O-Ring Push tubing straight in as far as it will go. 1 Pull tubing straight out. 2 T o Attach T ubing T o Release T ubing This product is outfitted with user friendly ‘Push In’ connectors.
10 Fig. 7 (FLOOR) Faucet without Air Gap 3/8” Blue T ubing* For refrigerator icemaker or water dispenser hookup, tee into tubing Feedwater T apping Valve Cold Water Supply Pipe 3/8” Y ellow T ubing* Storage T ank** 1/4” green tubing Air Gap Device (e.
11 Teflon is a registered trademark of E.I. DuPont O. APPENDIX FOR BASEMENT INST ALLA TIONS The following variations are generally required for basement installations: INSTALL THE DRAIN CONNECTION For basement installations, the drain saddle is generally not used.
P . INST ALLA TION TROUBLESHOOTING Problem: Leak at the feed water tapping valve. Cause: Tapping valve is not clamped tightly enough. Solution: Tighten the tapping valve clamp screws evenly and firmly keeping both halves of the bracket parallel. Be sure not to deform tubing.
A. IMPORT ANT WA TER QUALITY ASSURANCE REQUIREMENTS Reverse Osmosis drinking water appliances contain treatment components that are critical for the effective reduction of Total Dissolved Solids (TDS) as well as inor- ganic chemical contaminants.
When to Replace the RO Membrane Cartridge • As determined by a built-in percent rejection (PR) monitor: The monitor is factory preset so that a green light will be displayed when the water quality is good, and a red or yellow light indicates that cartridge replacement may be necessary.
1) Close the feed water tapping valve and lift up on the faucet handle to empty the water in the storage tank. It should feel light when empty. 2) Shut off the faucet and close the valve at the top of tank. Disconnect the 3/8" yellow tubing from the back for the purification assembly.
CUNO Incorporated 400 Research Parkway Meriden, CT 06450, U.S.A. Toll Free: 1-800-733-1199 Worldwide: 203-237-5541 Fax: 203-238-8701 www.waterfactorysystems.
デバイスCuno SQC Seriesの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Cuno SQC Seriesをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはCuno SQC Seriesの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Cuno SQC Seriesの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Cuno SQC Seriesで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Cuno SQC Seriesを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はCuno SQC Seriesの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Cuno SQC Seriesに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちCuno SQC Seriesデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。