November 2013 78-0013-1746-6-E 3 3M ™ Crimplok ™ + Connector 8700-UPC & APC SM SC 250/900µm 6700-50 SC 50 µm MM 250/900 µm 6700-50/LOMMF SC 50 µm LOMMF 250/900 µm 6700-62.5 SC 62.5 µm MM 250/900 µm Ins tr uc tions The Network of Networks.
2 78-0013-1746-6-E Safet y Precautions Pr o te c ti ve E yewea r CAUTION T o reduce the risk associated with eye injury: - Safety glasses should be worn when handling chemicals and cleaving the optical ber .
3 78-0013-1746-6-E 1.0 Over view 1.1 3M ™ Crimplok ™ + Connectors 8700-UPC & APC terminate 250 µm and 900 µm singlemode fibers, and the Crimplok+ 6700 series connectors terminate 250 µm and 900 µm multimode fibers for excellent optical performance.
4 78-0013-1746-6-E 1.3 Additional materials needed: • De-ionized or distilled water for nano-finishing at above-freezing temperatures • 25% to 35% methanol by volume and 75% to 65% de-ionized or distilled water solution by volume for nano-finishing at below-freezing temperatures.
5 78-0013-1746-6-E 2.3 Remove the 3M ™ Crimplok ™ + Connector from the bag and remove the dust cap from the ferrule. Remove the lapping film disc from the bag and set it aside for later . 2.4 Insert the connector into the SC port with the actuation cap facing upward.
6 78-0013-1746-6-E 3.3 For 900 µm, determine if the fiber is tight or semi- tight buffer . If the 900 µm slides easily from the fiber, it is semi-tight buffer fiber . If not, it is tight buffer . Break-out kits for 250 µm are semi-tight. Make note of tight or semi-tight for step 3.
7 78-0013-1746-6-E 3.8 Close the left cover . Close the right cover . Push the shuttle forward to cleave the fiber . 3.9 Open the right cover . Use tweezers to carefully grab the glass shard. Discard it in the shard container . CAUTION: The glass shard is sharp and can pierce the skin.
8 78-0013-1746-6-E 3.1 1 Lay the fiber in the track running through the center of the fiber holder . Use the “TIGHT BUFFER” or “SEMI- TIGHT BUFFER” slits as appropriate. Reference section 3.3 to determine which fiber type. Tight buffer Semi-tight buffer 3.
9 78-0013-1746-6-E 3.14 Rotate the fiber so the fiber curl is directed downward in the fiber holder . 3.15 Hold fiber at rear , and pull the fiber backward. Position the fiber so the tip is flush (±1 mm) with the end of the nozzle. Note: The 900 µm coating edge can be seen through a hole in the shuttle.
10 78-0013-1746-6-E 4.0 Fiber Insertion and Connector Activation 4.1 Grip the back of the fiber holder . Do not grip the front or middle lids, because they may need to pop open. Slowly insert the fiber holder (with cleaved fiber) into the guide track on the protrusion setting tool until it reaches a stop.
11 78-0013-1746-6-E 4.4 For 250 µm only , the fiber will bow in the nozzle slot. No lids will open with 250 µm. Note: Bowing these 3 different fiber coating types at 3 different lengths enables consistent fiber protrusion setting. 250 µm coating 4.
12 78-0013-1746-6-E 4.7 Press down hard on the free end of the activation lever to activate the fiber crimping mechanism within the connector . After a click sound, the lever will be stopped and cannot be pushed any further . Note: Never activate a connector without a fiber in it or with a fiber only partially inserted.
13 78-0013-1746-6-E 4.9 Open the covers and buffer clamp (if necessary) on the fiber holder (for stif f-coated fiber , the buffer clamp was already opened). Slide the fiber holder out of the guide track in the protrusion setting tool, leaving the connector and fiber behind.
14 78-0013-1746-6-E 5.2 W et the top surface of the finishing disc with 2 squirts of de-ionized water using the spray bottle provided. A void using excessive amounts of water . Close the lid fully and ensure the latch is engaged. Note: W etting the disc surface is important because it carries off glass particles that have been removed.
15 78-0013-1746-6-E 5.7 Remove the lapping film. Inspect the lapping film for fiber tracks. If the film has tracks, dispose of it. If not, restart at step 5.1. APC UPC 5.8 Dry the connector using a new lint-free wipe. Do not use the same wipe used for stripping fiber .
16 78-0013-1746-6-E 5.9 Before the network has a laser light source feeding your connector , inspect the fiber end face with 3M ™ 200X V iew Scope 6365-VS if you have one. If the fiber end face looks acceptable per photos to the right, then re-insert the connector into the protrusion setter and activate the buffer clamp per step 4.
17 78-0013-1746-6-E 6.0 Connector Reusability 6.1 Should it become necessary to separate the connector and fiber , e.g. to reset the fiber protrusion, the activation cap within the connector can be deactivated. This is accomplished by first removing the connector from the port on the protrusion setting tool.
3M, Lightvision and Crimplok are trademarks of 3M Company . Important Notice All statements, technical information, and recommendations related to 3M’ s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed.
デバイス3M 6700-50/LOMMF SC 50 m LOMMF 250/900 mの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
3M 6700-50/LOMMF SC 50 m LOMMF 250/900 mをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこには3M 6700-50/LOMMF SC 50 m LOMMF 250/900 mの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。3M 6700-50/LOMMF SC 50 m LOMMF 250/900 mの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。3M 6700-50/LOMMF SC 50 m LOMMF 250/900 mで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
3M 6700-50/LOMMF SC 50 m LOMMF 250/900 mを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又は3M 6700-50/LOMMF SC 50 m LOMMF 250/900 mの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、3M 6700-50/LOMMF SC 50 m LOMMF 250/900 mに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわち3M 6700-50/LOMMF SC 50 m LOMMF 250/900 mデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。