DatalogicメーカーC-BOX 300の使用説明書/サービス説明書
ページ先へ移動 of 38
C-BOX 300/310 Installation Manual.
.
C-BOX 300/310 IN ST AL L ATI ON M ANU AL.
DATALOGIC S.p.A. Via Candini 2 40012 - Lippo di Calderara di Reno Bologna - Italy C-BOX 300/310 Ed.: 03/2006 ALL RIGHTS RESERVED Datalogic S.p.A. reserves the right to make modifi cations and improvements without prior no tification.
CONTENTS GUIDE TO INST ALLATION ........................................................................ iv GENERAL VIEW .......................................................................................... v SAFETY PRECA UTIONS .................
GUIDE TO INSTALLATION The following can be used as a checklist to verify all of the steps necessar y for complete installation of the C-BOX 3X0. 1) Rea d all information in the section "S afet y Precautions" at the beginning of this manual.
GENERAL VIEW C-BOX 300 2 3 4 1 Figure A 25-pin scanner connector Cove r screw s (4) Compre ssio n con nect ors 1 2 3 Prof ibus con nector 4 v.
C-BOX 310 2 1 Figure B LCD display Ke ypad 1 2 vi.
C-BOX 300/310 3 2 1 8 6 5 4 7 Figure C - Cover Inside LCD con trast tri mmer* 1 2 Power on LED 3 BUS activity LE D 4 Tx L ED 5 Module status LEDs 6 7 8 Configuration switch Node address select ors W a.
C-BOX 300/310 6 7 8 5 9 4 2 3 1 10 Figure D - Bottom Inside Pow er o n sw itch 1 2 S canner grounding selec tor 3 S pring clam p term inal blocks 5 4 GET button TEST button 6 SEND button 7 8 A uxiliar.
SAFETY PRECAUTIONS POWER SUPPLY ATTENTION: READ THIS INFORMATION BEFORE INSTALLING THE PRODUCT - This product is intended to be installed by Qualified Personn el only. The C-BOX 3X0 is intend ed to be supplied either by a UL Listed NEC Cl ass 2 power source, or a UL Listed ITE Limited Po wer Source (LPS), rated 10-30 V dc, minimum 0.
Terminating Resistors Terminating resist ors must be us ed if the C-BOX is installed at the begin ning or end of the PROFIBUS cable segment. In this case, it is recommende d to use PROFIBUS connectors which contain an integrate d terminating resistor.
GENERAL FEATURES 1 1 GENERAL FEATURES 1.1 DESCRIPTION The C-BOX 3X0 is a c onnection box whic h converts RS232 communications t o Profibus. It is available in two models: C-BOX 300, without display, C-BOX 310, with LCD display.
C-BOX 300/310 2 2 INSTALLATION 2.1 PACKAGE CONTENTS Verify that the C-BOX 3 X0 and all the parts supplied w ith the equipm ent are present and intact when opening the packagin g; the list of parts inc.
INSTALLATION 2 2.2 OPENING THE DEVICE To install the C-BOX 3 X0 or during normal ma intenance, it is necessary to open it b y unscrewing the four cover screws: CA UTIO N The C-BOX 3X0 must be disconnected from the power supply during this operation.
C-BOX 300/310 2 2.3 MECHANICAL INSTALLATION The diagram below gives the overall dimens i ons of the C-BOX 3X0 and m ay be used for its installation. = 165 [6.
INSTALLATION 2 C-BOX 3X0 can be installed to operate in different positions. The two screw holes inside the housing of the C-B OX 3X0 ar e for mechanical fixture (Figure 4). To mount the C-BOX 3X0: 1) Open the C-BOX 3X0 by unscre wing the 4 cover screws.
C-BOX 300/310 2 2.4 ELECTRICAL CONNECTIONS AN D HARDWARE SETUP The following figure shows the typical layout. PROFIBUS MASTER C-BOX 3X0 SCANNER System Cables Figure 5 – System La yout NOTE Matrix readers are not compatible w ith the WinHost configuration program.
INSTALLATION 2 NOTE Autoconnection is not c ompatible with Matrix readers and must be disabled in the C-BOX 3x0 confi guration. Se e par. 2.9 for details.
C-BOX 300/310 2 NOTE Pin 1 is also electrical ly connected to pins 3 and 5, just as pin 2 is electrically connected to pins 4 and 6. This is useful for external trigger/inputs connections. WA RN ING Incorrect grounding of the C-BOX 3X0 can in jure personnel and damage equipment.
INSTALLATION 2 2.4.2 System Wiring The connection and wiring pr ocedure for C-BOX 3X0 is described as follows: 1) Open the C-BOX 3X0 as de s cribed in paragraph 2.2. 2) Verify that the C-BOX 3X0 power switch is off (see Figure 6). 3) Unscrew the compression connectors and pass all the system cables through them into t he C-BOX 3X0 housing.
C-BOX 300/310 2 The C-BOX 3X0 spring clamp connector pi nout s are indicated in the follo wing table. Refer to the scanner Insta llation Manual for details.
INSTALLATION 2 2.4.3 Scanner Chassis Grounding Jumper Settings The scanner chassis grounding method can be selected by positioning a jumper (see Figure 9). In this w ay the scanner c hassis can be connected to earth gr ound (only if pins 7 or 8 are connecte d to a good earth ground) or to the po wer supply ground signal.
C-BOX 300/310 2 2.5 PROFIBUS CONNECTIONS AND SETUP 2.5.1 Profibus Node Address Selection To interface the C-BOX 3X0 with a Profib us network, the Node Address should be set using the rotary switches placed in th e cover inside. The valid address range is from 000 to 126.
INSTALLATION 2 9-pin external female c onnector pinout Pin Name Function 1 N.C. not connected 2 N.C. not connected 3 B-LINE (RS485+) 4 RTS Ready To Send 5 GND RS485 Bus Reference 6 + 5V (galvanically isolated) RS485 Bus Power Supply 7 N.C. not connected 8 A-Line (RS485-) 9 N.
C-BOX 300/310 2 To ensure that the C-BO X functions without errors, the shield of the PROFIBUS cable must be grounded. – Ensure that the PROFIBUS connector uses the pi n assignments shown in par 2.5.2 – Attach the PROFIBUS connector to the PROFIBUS interface socket on the C-BOX 3X0 and secure the connector with the retaining screws.
INSTALLATION 2 2.6 CONFIGURATION SWITCH AND 9-PIN INTERNAL CONNECTOR The 9-pin internal c onnector may have t wo different functions according to the position of the conf iguration s witch.
C-BOX 300/310 2 POSITION MODE CFG : When the switch is in this position, the C-BOX 3X0 is in configuration mode. The communicati on with the scanner is interrupted and pins 2 and 3 ar e no longer dedicated to the scan ner auxiliary interface but to the C-BOX 3X0 c onfiguration (see tab le below).
INSTALLATION 2 2.7 SCANNER REQUIREMENTS The C-BOX 3X0 can be connecte d to the following scanners through the 25-pin connector illustrated in Figure A. DS2100A DS4600A *Matrix-2000™ DS2400A *Matrix-1000™ 1) For all scanners, it is neces sary to use the RS232 inter face which must be selected by the user .
C-BOX 300/310 2 2.8.1 GET/TEST/SEND Functions The C-BOX 300 has three internal function buttons. In th e C-BOX 310, they are also available on the cover, and their function is indicated o n the display. C-BOX 300 GET TE ST SEND C-BOX 310 Figure 14 – Internal Functi on Buttons NOTE The GET/TEST/SEND function is not co mpatible with Matrix readers.
INSTALLATION 2 GET – (left button): the C-BOX 3X0 reads th e curr ent scanner configuration and permanently copies it in its own memory support (EEPRO M).
C-BOX 300/310 2 2.8.2 LED Indicators Figure 15 - LED Indicators TX L ED MS LEDs Warning LED BUS activity Power on In the C-BOX 3X0 the Warning LED is repeated in the b ottom inside.
INSTALLATION 2 The internal LEDs of the C-BOX 3X0 (see Fig ure 15) indicate the following: POWER ON ( PWR ) (red) indicates the C-BOX 3X0 is connected to the power supply and the power switch is ON. WARNIN G ( WL ) (red) indicates a wa rning or e rror condition.
C-BOX 300/310 2 2.9 SPECIAL NOTES FOR MATRIX RE ADER SETUP CAUTION When connected to a C-BOX 3x0 through the 25-pin connector , the 9-pin Auxiliary port co nnector on the Matrix reader ca nnot be used for communication (i.e. config uration through VisiSet™).
INSTALLATION 2 2.9.2 Matrix Reader Configuration Using VisiSet™ After performing C-Box 3x0 config uration as described in the previo us paragraph, the Matrix reader can be co nfigured through the C-Bo x 3x0 9-pin internal connector connected to the PC using the Vi siSet™ configuration program: 1.
C-BOX 300/310 2 Figure 18 – WinHost Configurat ion Menu for C-Box 3x0 6. Close the C-BOX 300. 24.
TECHNICAL FEATURES 3 3 TECHNICAL FEATURES ELECTRICAL FEATURES C-BOX 300 C-BOX 310 Power Supply voltage 10 to 30 Vdc Power consumption max. 2.9 W + scanner 4.7 W + scanner USER INTERFACE LED indicators Pow er O N, W arn ing , Tx, Diagnostics PHYSICAL FEATURES Mechanical dimensions 167 x 115 x 61 m m (6.
DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy 05 dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el C-BOX-3X0 e tutti i suoi mo de.
デバイスDatalogic C-BOX 300の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Datalogic C-BOX 300をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDatalogic C-BOX 300の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Datalogic C-BOX 300の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Datalogic C-BOX 300で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Datalogic C-BOX 300を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDatalogic C-BOX 300の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Datalogic C-BOX 300に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDatalogic C-BOX 300デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。