C-BO X 200 Installation Manual.
C-BOX 200 INSTA LLA TION MANUA L.
01 DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el C-BOX 200, active con nection .
iii CONTENTS GUIDE TO INSTALLA TIO N .............................................................. iv SA F ETY PRECA U TIO NS ................................................................. vii Power Supply .........................................
iv GUIDE TO INSTA LLA TI ON The following can be used as a check list to verif y all of the steps neces sary for c om plete installation of the C- BOX 200. 1) Read all inf orm ation in the sec tion "Safety Precautions" at the beginning of this m anual.
v C-BOX 200 General View 1 2 3 Figure A 25-pin scan ner connector Cover screws (4) Compression connectors 1 2 3.
vi C-BOX 200 General View 4 10 1 2 6 7 8 9 12 5 3 11 Figure B Pow er swit ch (ON /OFF) 1 2 Spring clamp terminal b locks 3 Mul tidrop address switches 5 4 Po wer on LED Wa rn i ng LE D 6 Tx LE D 7 GET.
vii SA FETY PRECA UTIONS POWER SUPPLY ATT ENTION: READ THIS INFORMATION BEFORE INST AL LING THE PRODUCT - This product is intended to be ins talled by Qualified Personnel only. The C-BO X 200 is intended to be s upplied by an NEC Class 2 power source, rated 10-30 V, m inim um 0.
viii.
DA TA LOGIC C-BOX 200 General Features - 1 1 GENERA L FEA TURES 1.1 DESCRIPTION The C-BO X 200 is a c onnection box which c an be used as an acces sory of the Datalogic scanner s to perf orm the following func tions: • Facilitate the connection of the scanner s ignals using a spr ing clam p connector.
C-BOX 200 DA TALOGIC 2 - Installa tion 2 INSTA LLATION 2.1 PACKA GE CONTENTS Verify that the C-BOX 200 and all the parts supplied with the equipm ent are present and intact when opening the pack aging; the list of parts inc ludes: 1) C-BOX 200 2) Installation m anual 1 2 Figure 2.
DA TA LOGIC C-BOX 200 Installatio n - 3 2.2 OPENING THE DEVIC E To install the C-BOX 200 or during nor mal m aintenanc e, it is neces sary to open it by unscrewing the f our cover s crews: WA RNING The C-BO X 200 m ust be disconnec ted f rom the power supply during this operation.
C-BOX 200 DA TALOGIC 4 - Installa tion 2.3 MECHANICA L INSTA LLATION The diagram below gives the overall dim ensions of the C-BOX 200 and m ay be used for its installation.
DA TA LOGIC C-BOX 200 Installatio n - 5 C-BOX 200 c an be installed to operate in dif fer ent positions. T he two s crew holes inside the housing of the C-BOX 200 are f or m echanical f ixture ( Figure 2.4). To m ount the C-BO X 200: 1) Open the C-BOX 200 by unscrewing the 4 cover sc rews.
C-BOX 200 DA TALOGIC 6 - Installa tion 2.4 ELE CTRICA L CONNECTIONS AND SETUP The following figure shows the ty pical layout. The dotted line in the figure refer s to an optional hardware conf iguration. PC SCANNER System C ables Scanner Auxiliary Interface Figure 2.
DA TA LOGIC C-BOX 200 Installatio n - 7 2.4.1 Powe r Supply Power is supplied to the C-BOX 200 through the pins provided on the spring clam p connector. The power switch (see F igure 2.6) switches the power supply ON or OFF for both the C-BOX 200 and the c onnected sc anner.
C-BOX 200 DA TALOGIC 8 - Installa tion 2.4.2 Sy stem Wiring The c onnection and wiring procedure f or C-BO X 200 is des cribed as f ollows: 1) Open the C-BOX 200 as desc ribed in paragraph 2.2. 2) Verify that the C-BOX 200 power switch is off (see F igure 2.
DA TA LOGIC C-BOX 200 Installatio n - 9 The C-BO X 200 spr ing clam p connector pinouts are indicated in the f ollowing table. Refer to the sc anner Installation Manual for deta ils.
C-BOX 200 DA TALOGIC 10 - Installa tion 2.4.3 Chassis Grounding Jumper Settings The s canner chas sis grounding m ethod c an be selected by positioning a jum per (see Figure 2.9). In this way the scanner chassis can be connected to earth ground (only if pins 7 or 8 are connec ted to a good earth ground) or to the power supply gr ound signal.
DA TA LOGIC C-BOX 200 Installatio n - 11 2.4.4 Multidrop A ddress Selection For RS485 half -duplex interf ace connec tions, the sc anner m ultidrop addr ess should be set using the r otary switches placed inside the C-BOX 200. The valid addr ess range is fr om 00 to 31.
C-BOX 200 DA TALOGIC 12 - Installa tion 2.4.5 RS485 Bus Terminat ion ON S2 OFF Figure 2.11 - Terminati on resistance swi tch The switch S2 enables or disables the insertion of the bus term ination resistor for RS485 Half Duplex Multidr op applications.
DA TA LOGIC C-BOX 200 Installatio n - 13 2.4.6 Connection to a Multiplexer The f ollowing figure shows a m ultidrop layout with C-BOX 200 devices connected to a Multiplexer : MULTIP LEX ER C-BOX 20 0 .
C-BOX 200 DA TALOGIC 14 - Installa tion 2.4.7 OM4000 Jumper Sett ings J1 J2 Figure 2.13 - OM 4000 jumpers The jum pers allow c onnection to the EXT TRIG signals on separ ate spring clam p terminals for applic ations which use the O M4000 Osc illating Mirror in Trigger Mode.
DA TA LOGIC C-BOX 200 Installatio n - 15 2.5 9-PIN SCA NNER A UXILIA RY SERIA L INTERFA CE The s canner auxiliar y serial interface available on the internal 9-pin connector c an be used either f or conf iguration through W inHost or for data monitor ing.
C-BOX 200 DA TALOGIC 16 - Installa tion 2.6 SCANNER REQUIREMENTS 1) T he C-BOX 200 c an be connected to the f ollowing scanners thr ough the 25-pin connector illustrated in F igure A.
DA TA LOGIC C-BOX 200 Installatio n - 17 2.7.1 GET/SEND Butt ons The C-BO X 200 has two internal function buttons (GET , SEND) . T he procedure to enable the G ET/SEND f unction is the f ollowing: 1. Press both the buttons GET and SEND at the same tim e for at least one second; the warning LED is tur ned ON.
C-BOX 200 DA TALOGIC 18 - Installa tion 2.7.2 LED Indicators Power on Wa rn i ng Tx Figure 2.15 - LED Indicators The three internal LEDs of the C-BO X 200 (see F igure 2.15) indicate the following: POWER ON (red) indic ates the C-BOX 200 is connec ted to the power supply and the pow er switch is O N.
DA TA LOGIC C-BOX 200 Technical Features - 19 3 TECHNICA L FEA TURES ELECTRICAL FEA T URES Power Supply volt age 10 to 30 Vdc Power consum ption m ax. 1.4 W + s canner USER INTERFACE LED indi cators Pow er ON , W arni ng, Tx (RS485 Multidrop activi ty) P H Y SI C AL F EAT U R E S Mechanical di mens ions 167 x 115 x 40 mm (6.
デバイスDatalogic Scanning C-BOX 200の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Datalogic Scanning C-BOX 200をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDatalogic Scanning C-BOX 200の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Datalogic Scanning C-BOX 200の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Datalogic Scanning C-BOX 200で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Datalogic Scanning C-BOX 200を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDatalogic Scanning C-BOX 200の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Datalogic Scanning C-BOX 200に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDatalogic Scanning C-BOX 200デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。