Dell Storage Center SCv2000 and SCv2020 Storage System Getting Started Guide Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001.
Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death.
Before You Begin Consider the following best practices before setting up your SCv2000/SCv2020 storage system. • Dell recommends that you use a dedicated SAN network for data transmission when using a Fibre Channel or iSCSI storage system. • Complete the Worksheet to Record System Information in this guide before configuring the storage system.
Class I laser products are not considered to be hazardous. The laser system and unit are designed so there is never any human access to laser radiation above a Class I level during normal operation, user maintenance or prescribed service condition.
Worksheet to Record System Information Use the following worksheet to record the information that is needed to install the SCv2000/SCv2020 storage system . Storage Center Information Gather and record the following information about the Storage Center network and the administrator user.
IPv4 address for storage controller module 1: port 1 ___ . ___ . ___ . ___ IPv4 address for storage controller module 2: port 1 ___ . ___ . ___ . ___ (Four port I/O card only) IPv4 address for storage controller module 1: port 3 ___ . ___ . ___ . ___ (Four port I/O card only) IPv4 address for storage controller module 2: port 3 ___ .
Table 6. Physical WWNs in Fault Domain 1 Physical WWN of storage controller 1: port 1 ________________ Physical WWN of storage controller 2: port 1 ________________ (Four port I/O card only) Physical WWN of storage controller 1: port 3 ________________ (Four port I/O card only) Physical WWN of storage controller 2: port 3 ________________ Table 7.
• The Dell Storage Center Dell Storage Client Administrator’s Guide describes how to use the Dell Storage Client to manage a Storage Center. Installation and Configuration Before you begin install.
Figure 2. Hole Locations in Rack 1. Middle hole of top 1U 2. Top hole of bottom 1U 3. Bottom hole of bottom 1U 6. Slide the storage system chassis onto the rails. Figure 3. Mount the SCv2000/SCv2020 Storage System Chassis 7. Secure the storage system chassis to the rack using the mounting screws within each chassis ear.
Figure 4. Front Bezel 2. Insert the left end of the bezel into the securing slot until the release latch snaps into place. 3. Secure the bezel with the keylock. Front-End Cabling Front-end cabling refers to the connections between the storage system and host servers.
3. Connect fault domain 2 to switch 2. a. Connect a cable from storage controller 1: port 2 to switch 2. b. Connect a cable from storage controller 2: port 2 to switch 2. c. (Four-port I/O card only) Connect a cable from storage controller 1: port 4 to switch 2.
a. Connect a SAS cable from storage controller 1: port 4 to server 4. b. Connect a SAS cable from storage controller 2: port 4 to server 4. Figure 6. Storage System Connected Directly to Host Servers 1. Server 1 2. Server 2 3. Server 3 4. Server 4 5. SCv2000/SCv2020 storage system 6.
Figure 7. Storage System Connected to a Management Network 1. Management network switch 2. SCv2000/SCv2020 storage system 3. Storage controller 1 4. Storage controller 2 Back-End Cabling An SCv2000/SCv2020 storage system can be deployed with or without SC100/SC120 expansion enclosures .
NOTE: In an SCv2000/SCv2020 storage system, the top storage controller is storage controller 1 and the bottom storage controller is storage controller 2.
Figure 10. Power Cables 3. Secure each power cable to the storage system chassis using the strain relief fasteners. 4. Plug the other end of the power cables into a grounded electrical outlet or a separate power source such as an uninterrupted power supply (UPS) or a power distribution unit (PDU).
NOTE: To discover and configure a Storage Center, the software must be installed on a host server that is located on the same subnet as the storage system 3. Start the software by double-clicking the Enterprise Manager Client shortcut. The Dell Storage Client welcome screen appears.
Storage Connectivity Configurations Storage Center supports up to 168 drives in one redundant-path SAS chain • An SCv2000 supports up to 13 SC100 expansion enclosures or 6 SC120 expansion enclosures.
Power Supplies AC power supply (per power supply) Wattage 580 W (maximum wattage: 584 W) Voltage 100–240 VAC (7.6–3.0 A) Heat dissipation SCv2000 : 65 W at 230 VAC and 99 W at 115 VAC SCv2020 : 65.
Environmental Maximum vibration Operating 0.21 G at 5–500 Hz for 15 min Storage 1.04 G at 2–200 Hz for 15 min Maximum shock Operating Half-sine shock 5 G +/- 5% with a pulse duration of 10 ms +/- .
デバイスDell SCv2020の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Dell SCv2020をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDell SCv2020の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Dell SCv2020の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Dell SCv2020で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Dell SCv2020を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDell SCv2020の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Dell SCv2020に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDell SCv2020デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。