DeLonghiメーカーPAC160の使用説明書/サービス説明書
ページ先へ移動 of 18
PA C 160 PA C 160 • Use and maintenance manual . . . . pag. 4 • Mode d’emploi et d’entr etien . . . . . pag. 19 • Instrucciones de uso . . . .
D ear Customer , Thank you for purchasing an appliance made by De’ Longhi, the interna- tional leader in portable air conditioning units. Thanks to our years of experi- ence all around the world we are constantly improving the quality and per- for mance of Pinguino.
3 1 2 3 4 5 6 7 9 10 12 13 15 16 14 17 8 • D escription • D escription • Descriptción • D escrizione • ACCESSOR Y -SET • ACCESSOIRES A CCESSOIRES • A CCESSORI • CONTR OL P ANEL • P .
4 Impor tant S af e-guar ds When using electrical appliances, basic safety precautions should always be taken, with particular reference to the following: - Read all instructions. -T o protect against fire, electric shock and personal injury, do not immerse cable, plug or appliance in water or other liquid.
5 ENGLISH D uring the summer , optimum comfort is achieved with a temperature of between 75-80°F (24- 27°C) and about 50% relative humidity. An air conditioner removes moisture and heat from the room where it is located.
6 DESCRIPTION MODEL 1) Air discharge grill 2) Control Panel 3) Wheels 4) Handles 5) Housing for air exhaust hose 6) Cord winder 7) Air intake grill 8) Rating plate 9) W ater collection tank 10) Water .
7 ENGLISH 1 2 When positioning the appliance, always ensure that nothing obstructs the intake and discharge of air AIR CONDITIONING WITHOUT PERMANENT INST ALLA TION Only a few simple steps are necessary to obtain the comfort offered by Pinguino. • Fit the air exhaust hose (14) in its housing (5) at the rear of the appliance as shown in fig.
8 Pinguino is equipped with an adjustable win- dow bracket 18 . If you have a sliding window, place the bracket on the window sill, extend the bracket fully within the window frame and lower the window onto the bracket. Insert the nozzle of the exhaust hose into the slot, then connect the hose to the air conditioner (Fig.
9 ENGLISH Setting up AIR CONDITIONING WITH SEMI-PERMA- NENT INST ALLA TION If desired, Pinguino can also be installed on a semi-per manent basis fig. 7. • Fit the flange (13) supplied to the hole. • Fix the hose (14) in the housing at the rear of the appliance (fig 1) • Fit the end of the hose to the flange (15) as shown in fig.
10 D escription of the control panel ELECTRICAL CONNECTION Before plugging in check that: • the mains supply corresponds to the value shown in the specifications table; • the socket and the mains .
11 ENGLISH Oper ation SWITCHING THE APPLIANCE ON Connect the appliance to the mains supply. On the display two lines will appear indicating Stand-by mode Press the ON/OFF button ( A ) and then the MODE button until the relevant function indicator appears viz.
12 Once the dehumidifying function has been selected, the fan speed cannot be changed. The appliance will automatically select the correct fan mode. VENTILA TION Adjust the fan speed by pressing the “F AN” (Q) button, as illustra- ted in the air conditioning function.
13 ENGLISH Oper ation SELF-DIAGNOSIS The appliance is equipped with a self-diagnosis system which identifies any operating problems. IF THE DISPLA Y SHOWS… ….WHA T SHOULD YOU DO? H H P P HIGH PRESSURE Insert and re-insert the plug. If the problem persists, call the service centre.
14 Follow these recommendations to achieve maximum efficiency from your air conditio- ning unit: • Close the doors and windows in the room where the unit is functioning. The only exception is in the case of installation throu- gh a hole in the wall.
15 ENGLISH 1 2 Before cleaning or maintenance, switch of f the appliance by pressing the ON/OFF button (A) and always unplug it from the mains supply. CLEANING THE EXTERNAL UNIT We recommend cleaning the appliance with a slightly damp cloth. It should then be dried.
16 Tr oubleshooting PROBLEM CAUSES REMEDY The air-conditioner does not work • the power is off • the appliance is not plugged in • Plug it in The air-conditioner works only for a short time • .
ENGLISH 17 T echnical specification TECHNICAL SPECIFICA TION Power supply see rating plate Max. absorbed power in air conditioning “ Max. absorbed power when dehumidifying “ Refrigerating capacity* “ Number of fan speeds 2 + silent Max. air flow 460 m 3 /h Dimensions of internal unit: • width 452 mm 17.
18 LIMITED W ARRANTY We warrant each DE’LONGHI AIR-CONDITIONER to be free from defects in material and work- manship. Our obligation under this warranty is to provide one year parts and labor free f.
デバイスDeLonghi PAC160の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
DeLonghi PAC160をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDeLonghi PAC160の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。DeLonghi PAC160の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。DeLonghi PAC160で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
DeLonghi PAC160を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDeLonghi PAC160の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、DeLonghi PAC160に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDeLonghi PAC160デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。