DVPEN01-SL Ethernet Communication Module Operation Manual DVP-0204320-02.
.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 1 Wa r n i n g 3 Please r ead this instruction carefully befor e use and fo llow th is instruction to operate th e device in or der to prevent damage s on the device or injuries to st aff.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 2 5.10 Returning to Default Setting ................................................................................................... .. 29 6 APPLICA TION EXAMPLES....................
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 3 1 Introduction Thank you for choosing DVPEN01-SL module. T o correctly install and operate DVPEN01-SL, please read the manual carefully before using the module. DVPEN01-SL is an Ethernet communication module for remote setting and communication through WPLSoft.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 4 Item S pecification S torage: -25 ° C ~ 70 ° C (temperature), 5 ~ 95% (humidit y) Vibration/ Shock Resistance S tandard: IEC61 131.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 5 2.3 LED Indicators Indicator Color Indication POWER Green Power indication RS-232 Red Communication st atus of the series port 100M Orange Network connection st atus LINK Green Network communication speed 2.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 6 Connect DVPEN01-SL to the Network: Connect DVPEN01-SL to t he Ethernet Hub by twisted pair cable CA T -5e. DVPEN01-SL has Auto MDI/MDIX function; therefore, DVPEN01-SL do es not need to use a crossing cabl e between the PC and DVPEN01-SL.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 7 CR# HW LW Attribute Content Explanation #7 R S tatus of E-Mail 1, 2 b0 ~ b7: Current status of E-Mail 2 b8 ~ b15: Current st atus of.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 8 CR# HW LW Attribute Content Explanation #1 15 R/W Modbus TCP trigger Setting up whether to send out dat a in Modbus TCP m ode #1 16 .
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 9 CR#7 ~ 8: S tatus of E-Mail 1 ~ 4 Explanations: 1. CR#7_b0 ~ b7: current status of E-Mail 2; CR#7_b8 ~ b15: current status of E-Mail 1. 2. CR#8_b0 ~ b7: current status of E-Mail 4; CR#8_b8 ~ b15: current status of E-Mail 3.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 10 CR value S tatus 0 Data have not yet been received. 1 Data excha nge is in progress.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 11 CR#83: Read Length for Dat a Exchange Explanations: Setting up the Modbus address of the r egiste r for Master data exchange. CR#84: W ritten-in Address for Data Exchange Explanations: Setting up manually the Modbus addres s of t he register for Slave dat a exchange.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 12 CR#1 14: Modbus TCP Time-O ut Explanations: Setting up the communication time-out (in ms) for Mo dbus TCP mode. CR#1 15: Modbus TCP Tr igger Explanations: When the CR value is set as “1”, Modbus TCP will be triggered.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 13 CR#251: Error Code Explanations: T able of error code: Bit No. Error b0 The network is not yet connected. b1 Incorrect IP setting b2 CR#13 is set as “tran smitting data”, but the dat a exchange is forbidden.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 14 5 Setting up Sof tware This section gives instructions o n how to set up DV PEN01 -SL by DCISoft and explanations on each setup page. Before you st art a setup page, you have to select “Ethernet” in the commu nic ation setting.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 15 Broadcast search 1. Click broadcast icon in DCISoft to search for all Delt a Ethernet products on the network. The window on the lef t hand side shows the model s foun d, and the window on the right hand side displays the device list of all models.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 16 3. Y ou will see the basic setup page as follow . Designating model to search 1. Right click “Et hernet” on the left hand side windo w and select “Configure” to desi gnate a model to search for .
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 17 2. After configure a model, sele ct “DVPEN01-SL” and click “OK” to auto-search for DVPEN01-SL modules on the network.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 18 Searching by IP address 1. Set the communication type to “Etherne t” and enter the IP address. Click “OK”. 2. Click “IP Search” icon to st ar t searching for the designated IP .
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 19 Opening DVPEN01-SL setup page by RS-232 1. Select “RS232" as the transmission type in communication setting. Y ou will have to designate a communication port. When DVPEN01-S L is searched by RS-232, you do not need to set up the parameters (i .
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 20 5.2 Basic Settings The basic settings in clude parameters a s module name, language, enabling Mo dbus TCP and time correction. Setting up DVPEN01-SL basics 1. Module Name: There can be many DVPEN01-SL mo dules in the network.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 21 7. T ime Zone: A time zone is a region of the Earth that has adopted the same st andard time, usually referred to as the local time.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 22 3. Click on “Internet Protocol (TCP/IP). 4. Enter 192.168.0.1 into IP address. Click on “OK” to complete the IP address setting of the PC.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 23 Setting up DVPEN01-SL Net work 1. IP configuration: There are two types of IP, static IP and DHCP. S tatic IP: Preset or manually modified by the user . DHCP: Automatically updated by the server .
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 24 5.4 Setting up E-Mails E-mail is the abbreviation of electronic mail, which transmit s mails through the network.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 25 E-Mail will be sent to the desig nated recipient s w hen the E-Mail is triggered. T o trigger E-Mail, se t the value is CR#3 ~ CR#6 as “1”. 6. See “Applicat ion Examples Section 6.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 26 receiving register In data exchange, DVPEN01-SL will execute Write ( Æ ) first before Read ( Å ). Quantity: A slave is able to send and receive at the same time maximum 100 con secutive data.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 27 of every slave: Digital I/O point s (RX+RY): 256 Analog (Read) register: 64 Analog (Write) regi ster: 64 5.7 IP Filter IP filter is used for restri cting the connect ion of the network in case some uncert ain IP will cause errors.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 28 Therefore, if you do not know the MA C address, you will have to spend some time looking up the MAC address. If you want to enhance the transmission ef ficiency , use stat ic ARP t able to save time.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 29 1. Modify: Check the box to modify the passwo rd. 2. New Password: Maximum 4 characters are allowed. Lea ve the column “blank” to disable the p assword protection function. 3. Confirm Password: Enter the new password a gain.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 30 Check “Default Setting” box and click o n “Y es”. Note: If you set up DVPEN01-SL by RS-232, you can return the setti ng to default setting whether the password is locked or not.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 31 3. Select “Ethernet” and press "OK”. 4. Click on “Auto-Search” icon to search for all DVPEN01-SL modules in the network. 5. Designate a DVPEN01 -SL and double click it to open the setup page.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 32 6. Open “Basic” setup p age. 7. Switch to “Network” setup page.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 33 8. Enter IP address: 192.168.0.4; Netmask: 255.255.255.0; Gateway: 192.168.0.1. Press “OK” to complete the setup, and WPLSoft will automatically search for DVPEN01-SL. 9. The IP of DVPEN01-SL ha s been modified into the new setting (DELTA DVPEN01-SL: 192.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 34 PC Hu b DH CP Serv er PC DVP- P LC DVPE N 01 2. Open “Communication Setting” in WPLSoft.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 35 4. Click on “Auto-Search” icon to search for a ll DVPEN01-SL modules in the network. Follow “View Æ Workspace Æ Communication” or “View Æ Workspace Æ Projec t” to find the detected DVPEN01-SL module (default module name: DELT A DVPEN01-SL, IP: 192.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 36 6. Open the setup page. You can modify the modul e name for easier identification. 7. Next, set up the new IP of DVPEN01-SL. First s w itch to “Network” setup page. If there is a DHCP server in the LAN, select DHCP in “IP Configuration”.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 37 6.3 Setting up Password and Clearing Password Application Setting up and clearing p assword by WPLSoft Network requirement (1) Set password in DVPEN01-SL (2) Unlock DVPEN01-SL (3) Clear the password in DVPEN01-SL 1.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 38 5. Enter the password to temporarily unlock the protecti on and modify the parameters. If you close the setup page, the locking will automatically be recovered. 6. To clear the password, simply leave the passw ord columns blan k.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 39 7. After the password is cleared, you can modify the parameters. 6.4 When the Password is Lost (Retur ning to Default Setting by RS-232) Application Returning to default setting by RS-23 2 Network requirement (1) DVPEN01-SL is set with a password.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 40 2. Check the “Default Setting” box an d the “Warning” dia log box will appear. Cli ck on “Yes” to ret urn to default setting (in approx. 5 ~ 10 seconds), and the password will be cleared as well.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 41 3. Check “Enable IP Filter Function” box. Enter “1 92.168.0.4” in No. 1 IP and “255.255.255.2 55” in all “Netmask” columns. 4. Enter “192.168.0.1” in No. 2 IP and “255.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 42 6.6 Setting up St atic ARP T able Application Setting up static ARP table Network requirement (1) MAC address of equipment 192.168.1.6 is 00:18:23:10 :00:35 (2) MAC address of equipment 192.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 43 4. Enter “192.168.1.1” in No.2 IP, and its MAC address is “00:18:23:10:00:04”. Cli ck on “OK” to complete the setting. Only the equipment within the IP range can be connected.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 44 6.7 Application of E-Mail Application Sending an E-Mail to notify the administr ator when the current status of X0 and Y0 is changed. Network application (1) SMTP Server IP: 172.16.144.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 45 4. Switch to “Select Recipients” pa ge. Check all the boxes of “Recipient 1”. C lick on “OK” to c omplete the setting. 5. After all the settings in DVPEN01-SL are comp leted, compile the ladder diag ram in the MPU and download it to the MPU.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 46 1. See 6.1 for how to set up the communication. 2. Open the setup page of PLC_B and switch to “Data Exchange” p age. 3. Check “Enable Data Exchange” box. Select “Program Control” for Execute Mode.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 47 END M101 3 K100 K1 K1 K100 K100 K1 M2 M1 M1 SET M1 TOP K2 8 TOP TOP K29 K14 K13 K0 D100 K7 K100 K1 TOP K 1 SET M2 M1 RST K100 K1 M2 K14 D14 RS T M2 RS T M2 = D 1 4 K 2 = D 1 4 K 3 FROM D1 00 TD R M100 0 Explanations: • The data exchang e will be executed every one secon d.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 48 6.9 Application of Dat a Exchan ge (2) Available in firmware V2.0 and later versio ns Application “Always Enable” Data Exchange. Enabl e a timer and write the timer values into D0 ~ D99.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 49 6.10 Application of Dat a Exchange (3) Available in firmware V2.0 and later versio ns Application Enable a timer (X20) and write the timer values into D0 ~ D99.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 50 After all the settings in PLC_A are completed, co mpi le the ladder diagram in the MPU and download it to PLC_A.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 51 END M101 3 K100 K1 K100 K100 K1 M2 M1 M1 SET M1 TOP K 2 8 TOP TOP K100 TOP SET M2 M1 RST K100 K1 M2 K14 D14 RST M2 RST M2 = D 1 4 K.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 52 6.12 Application of Dat a Exchange (5) Application Writing the time in RTC in PLC_B directl y into D0 ~ D6 of PLC_A without writing in ladder diagram into PLC_A. Network requirement (1) Adopting static IP.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 53 • Write “0” into CR#28, and PLC_B will u se CR# 25 ~ CR#26 as the IP address of the destination PLC. • Write the IP address of PLC_A into CR#25 and CR#26. The first two IP codes (192.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 54 K100 K1 TOP K100 TOP K1 K1 K0 K100 K1 TOP K100 TOP K1 H0 K6 K125 K1 19 K1 16 K1 15 SET M2 M1 RST MOV K0 D0 = D 0 K2 INC D 0 END K100 K1 M2 D14 RS T M2 RS T M2 = D 1 4 K 2 = D 1 4 K 3 FROM K1 16 Explanations: • The data exchang e will be executed every one secon d.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 55 1. See 6.1 for how to set up the communication. 2. Use DCISof t for RTU-EN01 to set up the mapping CR for read/write. 3. Use DCISoft for DVPEN01-SL to set up the m apping start address and numbe r of dat a.
Ethernet Communication Module DVPEN01-SL DVP-PLC Operation Manual 56 Explanations: 1. Enable mapping: CR15 = 1 2. Disable mapping: CR15 = 0 3. Once CR#15 is enabled, M2000 ~M2009 and D2000 ~ D2009 will read the data, and M3000 ~ M3009 and D3000 ~ D3009 will read the pre sent value before st arting to write.
デバイスDelta DVPEN01-SLの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Delta DVPEN01-SLをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDelta DVPEN01-SLの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Delta DVPEN01-SLの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Delta DVPEN01-SLで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Delta DVPEN01-SLを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDelta DVPEN01-SLの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Delta DVPEN01-SLに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDelta DVPEN01-SLデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。