Delta ElectronicsメーカーS48SAの使用説明書/サービス説明書
ページ先へ移動 of 13
DA T ASHEET DS_S48SA05006_060 22006 Delta Electronics, Inc. Delphi Series S48SA, 33W Family DC/DC Power Modules: 48V in, 5V/6.6A out The Delphi Series S48SA, surface mountable, 48V input, single output, isolated DC/DC converter is the latest offeri ng from a world leader in power system and technology and manu facturing – Delta Electronics, Inc.
DS_S48SA05006_060220 06 (T A =25°C, airflow rate=300 LFM, V in =48Vdc, nominal Vou t unless otherwise no ted.) TECHNICAL SPECIFICATIONS PARAMETER NOTES and CONDITIONS S48SA05006NRFA Min.
DS_S48SA05006_060220 06 ELECTRICAL CHARACTERISTICS CURVES 65 70 75 80 85 90 95 12 34 56 6 O UT P UT CURRE NT (A ) EFF IC IEN C Y ( %) . 6 36Vin 48Vin 75Vin 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 123456 OUTPUT CURRENT (A) POWER DISSIPATION (W) 6 . 6 36Vin 48Vin 75Vin Figure 1: Efficiency vs.
DS_S48SA05006_060220 06 4 ELECTRICAL CHARACT ERISTICS CURVES Figure5 : Turn-on transie nt at zero load current (2 ms/div). Top Trace: Vout (2V/div); Bottom Tr ace: ON/OFF Control (5V/div). Figure 6: Output voltage response to step-change in l oad current (50%-75% of Io, max; di/dt = 0.
DS_S48SA05006_060220 06 ELECTRICAL CHARACTERISTICS CURVES Strip Copper Vo(-) Vo(+) 10u 1u SCOPE RESISTIV E LOAD Figure 9 : Input Reflected Ripple Current, i s , at full rated output current and nominal i nput voltage with 12 µ H source impedance and 33 µ F electrolytic capacito r (2 mA/div).
DS_S48SA05006_060220 06 This power module is not internally fused. To a chieve optimum safety and system protection, an input line fuse is highly recommended. T he safety agencies require a normal-blow fuse with 3A maximum rating to be installed in the ungrounded le ad.
DS_S48SA05006_060220 06 Vo(+) Vi(+) Vo(-) Sense(-) Sense(+) Vi(-) ON/OFF Figure 13: Remote on/off implementation Remote Sense (Optional) Remote sense compensates for voltage drop s on the output by sensing the actual output voltage at the p oint of load.
DS_S48SA05006_060220 06 [] ΚΩ − ∆ − ∆ + = − 1 . 73 % Vo up 1690 %) 100 ( 69 Vo x. When trim-up +10% (5V X 1.1 = 5.5V) Rtrim E [] ΚΩ = − − + = − 9 .
DS_S48SA05006_060220 06 9 THERMAL CONSIDERATIONS Thermal management is an im porta nt part of the system design. To ensure proper, reliable operation, sufficie nt cooling of the power module is neede d over the entire temperature range of the modul e.
DS_S48SA05006_060220 06 10 PICK AND PLACE LOCATION SURFAC E-MOUNT TAPE & REEL RECOMMENDED PAD LAYOUT (SMD).
DS_S48SA05006_060220 06 11 Temp . Time 150 ℃ 200 ℃ 100~140 sec. Time Limited 90 sec . above 217 ℃ 217 ℃ Preheat time Ramp up max. 3 ℃ /sec. Ramp down max. 4 ℃ /s ec. Peak Tem p . 240 ~ 245 ℃ 25 ℃ Note: The temperature refers to the pin of S48SA, measured on the pin 1 (+Vout ) joint.
DS_S48SA05006_060220 06 Pin No. Name Function 1 +Vout Positive output voltage 2 -Vout Negative output voltage 6 Trim Output voltage trim 8 ON/OFF ON/OFF logic 11 -Vin Negative input voltage 12 +Vin Po.
DS_S48SA05006_060220 06 14 PART NUMBERING SYSTEM S 48 S A 050 06 N R F A* Form Factor Input Voltage Number of Outputs Product Series Output Voltage Output Current ON/OFF Logic Pin Type Option Code S- Small Power 48V S- Single A- Advanced 1R2-1.2V 1R5-1.
デバイスDelta Electronics S48SAの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Delta Electronics S48SAをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはDelta Electronics S48SAの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Delta Electronics S48SAの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Delta Electronics S48SAで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Delta Electronics S48SAを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はDelta Electronics S48SAの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Delta Electronics S48SAに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちDelta Electronics S48SAデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。